Hilde Færevik

Hilde Færevik

Auto-generated profile, based on publicly available information

Hilde Færevik

Sintef, Trondheim, Norway

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2008 in International Journal of Occupational Safety and Ergonomics
Verified
Journal Article
Closed access
RRRandi Eidsmo Reinertsen
Randi Eidsmo Reinertsen
HFHilde Færevik
Hilde Færevik
KHKristine Holbø
Kristine Holbø
RNRagnhild Nesbakken
Ragnhild Nesbakken
JRJarl Reitan
Jarl Reitan
MTMaria Suong Le Thi
Maria Suong Le Thi
Phase-change materials (PCM) can be used to reduce thermal stress and improve thermal comfort for workers wearing protective clothing. The aim of this study was to investigate the effect of PCM in protective clothing used in simulated work situations. We hypothesized that it would be possible to optimize cooling performance with a design that focuses on careful positioning of PCM, minimizing total insulation and facilitating moisture transport. Thermal stress and thermal comfort were estimated through measurement of body heat production, body temperatures, sweat production, relative humidity in clothing and subjective ratings of thermal comfort, thermal sensitivity and perception of wetness. Experiments were carried out using 2 types of PCM, the crystalline dehydrate of sodium sulphate and microcapsules in fabrics. The results of 1 field and 2 laboratory experimental series were conclusive in that reduced thermal stress and improved thermal comfort were related to the amount and distribution of PCM, reduced sweat production and adequate transport of moisture.

1 June 2003 in Ergonomics
Verified
Journal Article
Closed access
HFHilde Færevik
Hilde Færevik
RRRandi Eidsmo Reinertsen
Randi Eidsmo Reinertsen
Heat stress can be a significant problem for pilots wearing protective clothing during flights, because they provide extra insulation which prevents evaporative heat loss. Heat stress can influence human cognitive activity, which might be critical in the flying situation, requiring efficient and error-free performance. This study investigated the effect of wearing protective clothing under various ambient conditions on physiological and cognitive performance. On several occasions, eight subjects were exposed for 3 h to three different environmental conditions; 0°C at 80% RH, 23°C at 63% RH and 40°C at 19% RH. The subjects were equipped with thermistors, dressed as they normally do for flights (including helmet, two layers of underwear and an uninsulated survival suit). During three separate exposures the subjects carried out two cognitive performance tests (Vigilance test and DG test). Performance was scored as correct, incorrect, missed reaction and reaction time. Skin temperature, deep body temperature, heart rate, oxygen consumption, temperature and humidity inside the clothing, sweat loss, subjective sensation of temperature and thermal comfort were measured. Rises in rectal temperature, skin temperature, heart rate and body water loss indicated a high level of heat stress in the 40°C ambient temperature condition in comparison with 0°C and 23°C. Performance of the DG test was unaffected by ambient temperature. However, the number of incorrect reactions in the Vigilance test was significantly higher at 40°C than at 23°C (p = 0.006) or 0°C (p = 0.03). The effect on Vigilance performance correlated with changes in deep-body temperature, and this is in accordance with earlier studies that have demonstrated that cognitive performance is virtually unaffected unless environmental conditions are sufficient to change deep body temperature.

1 January 2011 in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Verified
Journal Article
Open access
PDF file
ØTØyvind Thomassen
Øyvind Thomassen
HFHilde Færevik
Hilde Færevik
ØØØyvind Østerås
Øyvind Østerås
GSGeir Sunde
Geir Sunde
EZErik Zakariassen
Erik Zakariassen
GBGuttorm Brattebo
Guttorm Brattebo
Accidental hypothermia increases mortality and morbidity in trauma patients. Various methods for insulating and wrapping hypothermic patients are used worldwide. The aim of this study was to compare the thermal insulating effects and comfort of bubble wrap, ambulance blankets / quilts, and Hibler's method, a low-cost method combining a plastic outer layer with an insulating layer. Eight volunteers were dressed in moistened clothing, exposed to a cold and windy environment then wrapped using one of the three different insulation methods in random order on three different days. They were rested quietly on their back for 60 minutes in a cold climatic chamber. Skin temperature, rectal temperature, oxygen consumption were measured, and metabolic heat production was calculated. A questionnaire was used for a subjective evaluation of comfort, thermal sensation, and shivering. Skin temperature was significantly higher 15 minutes after wrapping using Hibler's method compared with wrapping with ambulance blankets / quilts or bubble wrap. There were no differences in core temperature between the three insulating methods. The subjects reported more shivering, they felt colder, were more uncomfortable, and had an increased heat production when using bubble wrap compared with the other two methods. Hibler's method was the volunteers preferred method for preventing hypothermia. Bubble wrap was the least effective insulating method, and seemed to require significantly higher heat production to compensate for increased heat loss. This study demonstrated that a combination of vapour tight layer and an additional dry insulating layer (Hibler's method) is the most efficient wrapping method to prevent heat loss, as shown by increased skin temperatures, lower metabolic rate and better thermal comfort. This should then be the method of choice when wrapping a wet patient at risk of developing hypothermia in prehospital environments.

17 March 2012 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
MSMariann Sandsund
Mariann Sandsund
VSVegard Saursaunet
Vegard Saursaunet
ØWØystein Wiggen
Øystein Wiggen
JRJulie Renberg
Julie Renberg
HFHilde Færevik
Hilde Færevik
MBMireille C. P. van Beekvelt
Mireille C. P. van Beekvelt

21 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
IEIngrid Eitzen
Ingrid Eitzen
JRJulie Renberg
Julie Renberg
HFHilde Færevik
Hilde Færevik
Shock impacts during activity may cause damage to the joints, muscles, bones, or inner organs. To define thresholds for tolerable impacts, there is a need for methods that can accurately monitor shock impacts in real-life settings. Therefore, the main aim of this scoping review was to present an overview of existing methods for assessments of shock impacts using wearable sensor technology within two domains: sports and occupational settings. Online databases were used to identify papers published in 2010–2020, from which we selected 34 papers that used wearable sensor technology to measure shock impacts. No studies were found on occupational settings. For the sports domain, accelerometry was the dominant type of wearable sensor technology utilized, interpreting peak acceleration as a proxy for impact. Of the included studies, 28 assessed foot strike in running, head impacts in invasion and team sports, or different forms of jump landings or plyometric movements. The included studies revealed a lack of consensus regarding sensor placement and interpretation of the results. Furthermore, the identified high proportion of validation studies support previous concerns that wearable sensors at present are inadequate as a stand-alone method for valid and accurate data on shock impacts in the field.

1 January 2009 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
TLThomas Lango
Thomas Lango
RNRagnhild Nesbakken
Ragnhild Nesbakken
HFHilde Færevik
Hilde Færevik
KHKristine Holbø
Kristine Holbø
JRJarl Reitan
Jarl Reitan
RMRonald Mårvik
Ronald Mårvik
A laparoscopic surgeon sometimes experiences heat-related discomfort even though the temperature situation is moderate. The aim of this project was to design a cooling vest using a phase change material to increase thermal comfort for the surgeon. The project focused on the design process to reveal the most important parameters for the design of a cooling vest that could be demonstrated in a clinical setting. We performed an entire design process, from problem analysis, situation observations, concept for a prototype, temperature measurements, and a final design based on clinical testing. The project was conducted by a multidisciplinary team consisting of product designers, engineers, physiologists, and surgeons. We carried out four physiological demonstrations of one surgeon's skin temperatures and heart rate during different laparoscopic procedures. A commercially available cooling vest for firemen and two proof-of-concept prototypes were tested alongside a reference operation without cooling. To aid the final design, one person went through a climate chamber test with two different set-ups of cooling elements. The final design was found to improve the conditions of our test subject. It was found that whole trunk cooling was more effective than only upper trunk cooling. A final design was proposed based on the design process and the findings in the operating room and in the laboratory. Although the experiences using the vest seemed positive, further studies on several operators and more surgical procedures are needed to determine the true benefits for the operator.