State Research Center—Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency (SRC-FMBC), 46, Zhivopisnaya Str, Moscow 123098, Russia
Auto-generated profile, based on publicly available information
Ekaterina Arkhangelskaya
State Research Center—Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency (SRC-FMBC), 46, Zhivopisnaya Str, Moscow 123098, Russia
A comparative investigation of the induction of double-strand DNA breaks (DSBs) in the Chinese hamster V79 cells by γ-radiation at dose rates of 1, 10 and 400 mGy/min (doses ranged from 0.36 to 4.32 Gy) was performed. The acute radiation exposure at a dose rate of 400 mGy/min resulted in the linear dose-dependent increase of the γ-H2AX foci formation. The dose-response curve for the acute exposure was well described by a linear function y = 1.22 + 19.7x, where “y” is an average number of γ-H2AX foci per a cell and “x” is the absorbed dose (Gy). The dose rate reduction down to 10 mGy/min lead to a decreased number of γ-H2AX foci, as well as to a change of the dose-response relationship. Thus, the foci number up to 1.44 Gy increased and reached the “plateau” area between 1.44 and 4.32 Gy. There was only a slight increase of the γ-H2AX foci number (up to 7) in cells after the protracted exposure (up to 72 h) to ionizing radiation at a dose rate of 1 mGy/min. Similar effects of the varying dose rates were obtained when DNA damage was assessed using the comet assay. In general, our results show that the reduction of the radiation dose rate resulted in a significant decrease of DSBs per cell per an absorbed dose.
1 August 2014 in Free Radical Biology and Medicine
This study was undertaken to evaluate the compatibility of Giemsa staining protocol with the comet assay. We showed, for the first time, that DNA comets can be visualized and analyzed using Giemsa staining. We generated DNA damage dose response curves for human peripheral blood lymphocytes exposed to X-ray radiation using the comet assay with either SybrGreen I or Giemsa stain. The dose response curves were fitted by linear regressions (R2 > 0.977). The SybrGreen I results showed only ~1.2-fold higher slope coefficient (method sensitivity) compared to the Giemsa results. The unexpectedly high sensitivity of Giemsa staining for the comet assay is due to the Romanowsky-Giemsa effect, the stain photo-stability and the higher resolution of bright-field imaging compared to fluorescence imaging. Our results demonstrate that Giemsa staining can effectively be used for measuring DNA damage by the comet assay. The low cost and availability of Giemsa stain makes this method affordable for any low budget research and will facilitate new applications of the comet assay in biology and medicine.
The main goal of our study was to determine a set of thawed stallion sperm characteristics that have predictive value for the pregnancy rate (PR) of mares after artificial insemination (AI). DNA fragmentation and survival of sperm during hypothermic storage were studied in addition to routinely determined semen characteristics such as concentration, percentage of motile spermatozoa, and morphology. To estimate DNA fragmentation, a modified hallo assay was applied. Sperm survival was determined within hours as the ability of spermatozoa to maintain progressive motility (PM) during the storage of ejaculate diluted with lactose-chelate-citrate-yolk (LCCY) medium at +4 °C. Strong positive correlation between PR and thawed sperm motility (r = 0.90, p < 0.05) as well as between PR and sperm survival (r = 084, p < 0.05) was revealed. There was also a strong negative correlation between PR and DNA damages in spermatozoa (r = −0.94, p < 0.05). We found no dependence of PR on normal morphology spermatozoa percentage in thawed semen. We concluded that the sperm activity, survival, and DNA fragmentation should be considered as the sufficient reproductive characteristics of semen to evaluate the quality of frozen/thawed sperm and prediction of PR.