Eugene Knyazev

Eugene Knyazev

Auto-generated profile, based on publicly available information

Eugene Knyazev

Department of Physics and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2022 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
JHJoonseok Hur
Joonseok Hur
DCDiana P. L. Aude Craik
Diana P. L. Aude Craik
ICIan Counts
Ian Counts
EKEugene Knyazev
Eugene Knyazev
LCLuke Caldwell
Luke Caldwell
Vladan VuleticVladan Vuletic
Vladan Vuletic
Optical precision spectroscopy of isotope shifts can be used to test for new forces beyond the standard model, and to determine basic properties of atomic nuclei. We measure isotope shifts on the highly forbidden S21/2→F27/2 octupole transition of trapped Yb168,170,172,174,176 ions. When combined with previous measurements in Yb+ and very recent measurements in Yb, the data reveal a King plot nonlinearity of up to 240σ. The trends exhibited by experimental data are explained by nuclear density functional theory calculations with the Fayans functional. We also find, with 4.3σ confidence, that there is a second distinct source of nonlinearity, and discuss its possible origin.

30 May 2018 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
SDStefan L. Danilishin
Stefan L. Danilishin
EKEugene Knyazev
Eugene Knyazev
NVNikita V. Voronchev
Nikita V. Voronchev
FKFarid Ya. Khalili
Farid Ya. Khalili
CGChristian Gräf
Christian Gräf
SHStefan Hild
Stefan Hild
The recent discovery of gravitational waves (GW) by Advanced LIGO (Laser Interferometric Gravitational-wave Observatory) has impressively launched the novel field of gravitational astronomy and allowed us to glimpse exciting objects about which we could previously only speculate. Further sensitivity improvements at the low-frequency end of the detection band of future GW observatories must rely on quantum non-demolition (QND) methods to suppress fundamental quantum fluctuations of the light fields used to readout the GW signal. Here we present a novel concept of how to turn a conventional Michelson interferometer into a QND speed-meter interferometer with coherently suppressed quantum back-action noise. We use two orthogonal polarizations of light and an optical circulator to couple them. We carry out a detailed analysis of how imperfections and optical loss influence the achievable sensitivity. We find that the proposed configuration significantly enhances the low-frequency sensitivity and increases the observable event rate of binary black-hole coalescences in the range of $$10^2 - 10^3\,M_ \odot$$ 1 0 2 - 1 0 3 M ⊙ by a factor of up to ~300.

4 March 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
EKEugene Knyazev
Eugene Knyazev
FKFarid Ya. Khalili
Farid Ya. Khalili
MCMaria V. Chekhova
Maria V. Chekhova
Photon-number squeezing and correlations enable measurement of absorption with an accuracy exceeding that of the shot-noise limit. However, sub-shot noise imaging and sensing based on these methods require high detection efficiency, which can be a serious obstacle if measurements are carried out in “difficult” spectral ranges. We show that this problem can be overcome through the phase-sensitive amplification before detection. Here we propose an experimental scheme of sub-shot-noise imaging with tolerance to detection losses.

1 January 2018 in New Journal of Physics
Verified
Journal Article
Open access
PDF file
EKEugene Knyazev
Eugene Knyazev
KSKirill Spasibko
Kirill Spasibko
MCMaria Chekhova
Maria Chekhova
FKFarid Ya Khalili
Farid Ya Khalili

1 August 2018 in Physics Letters A
Verified
Journal Article
Open access
EKE. Knyazev
E. Knyazev
SDS. Danilishin
S. Danilishin
SHS. Hild
S. Hild
FKF.YA. Khalili
F.YA. Khalili
We propose a new implementation of a quantum speed meter QND measurement scheme. It employs two independent optical readouts of the interferometer test masses, featuring strongly different values of the bandwidths $\gamma_{1,2}$ and of the optical circulating power $I_{1,2}$, with the special relationship of $I_1/I_2=\gamma_1/\gamma_2$. The outputs of these two position meters have to be combined by an additional beamsplitter. In this scheme, signals at the common and the differential outputs of the interferometer setup are proportional to the position and the velocity of the test masses, respectively. The influence of the position meter-like back action force associated with the position signal can be cancelled using the EPR approach by measuring the amplitude quadrature of the beamsplitter common output correlated with this force. In the standard signal-recycled Michelson interferometer topology of the modern gravitational-wave detectors, two independent optical position meters can be implemented by two orthogonal polarisations of the probe light. Our analysis shows that the EPR speedmeter provides significantly improved sensitivity for all frequencies below $\sim 30\,{\rm Hz}$ compared to an equivalent signal recycled Michelson interferometer. We believe the EPR speedmeter scheme to be very attractive for future upgrades of gravitational wave detectors, because it requires only minor changes to be implemented in the interferometer hardware and allows to switch between the position meter and the speed meter modes within short time-scales and without any changes to the hardware.Comment: 14 pages, 5 figure

1 October 2018 in New Journal of Physics
Verified
Journal Article
Open access
TZTeng Zhang
Teng Zhang
EKE Knyazev
E Knyazev
SSS Steinlechner
S Steinlechner
FKF Ya Khalili
F Ya Khalili
BBB W Barr
B W Barr
SDS L Danilishin
S L Danilishin