OBJECTIVE: Navigation-enabling technology such as 3D-platform (O-arm) or intraoperative mobile CT (iCT-Airo) systems for use in spinal surgery has considerably improved accuracy over that of traditional fluoroscopy-guided techniques during pedicular screw positioning. In this study, the authors compared 2 intraoperative imaging systems with navigation, available in their neurosurgical unit, in terms of the accuracy they provided for transpedicular screw fixation in the thoracic and lumbar spine.METHODS: The authors performed a retrospective analysis of clinical and surgical data of 263 consecutive patients who underwent thoracic and lumbar spine screw placement in the same center. Data on 97 patients who underwent surgery with iCT-Airo navigation (iCT-Airo group) and 166 with O-arm navigation (O-arm group) were analyzed. Most patients underwent surgery for a degenerative or traumatic condition that involved thoracic and lumbar pedicle screw fixation using an open or percutaneous technique. The primary endpoint was the proportion of patients with at least 1 screw not correctly positioned according to the last intraoperative image. Secondary endpoints were the proportion of screws that were repositioned during surgery, the proportion of patients with a postoperative complication related to screw malposition, surgical time, and radiation exposure. A blinded radiologist graded screw positions in the last intraoperative image according to the Heary classification (grade 1–3 screws were considered correctly placed).RESULTS: A total of 1361 screws placed in 97 patients in the iCT-Airo group (503 screws) and in 166 in the O-arm group (858 screws) were graded. Of those screws, 3 (0.6%) in the iCT-Airo group and 4 (0.5%) in the O-arm group were misplaced. No statistically significant difference in final accuracy between these 2 groups or in the subpopulation of patients who underwent percutaneous surgery was found. Three patients in the iCT-Airo group (3.1%, 95% CI 0%–6.9%) and 3 in the O-arm group (1.8%, 95% CI 0%–4.0%) had a misplaced screw (Heary grade 4 or 5). Seven (1.4%) screws in the iCT-Airo group and 37 (4.3%) in the O-arm group were repositioned intraoperatively (p = 0.003). One patient in the iCT-Airo group and 2 in the O-arm group experienced postoperative neurological deficits related to hardware malposition. The mean surgical times in both groups were similar (276 [iCT-Airo] and 279 [O-arm] minutes). The mean exposure to radiation in the iCT-Airo group was significantly lower than that in the O-arm group (15.82 vs 19.12 mSv, respectively; p = 0.02).CONCLUSIONS: Introduction of a mobile CT scanner reduced the rate of screw repositioning, which enhanced patient safety and diminished radiation exposure for patients, but it did not improve overall accuracy compared to that of a mobile 3D platform.
Study Design.: A retrospective analysis of a single-center consecutive series of patients. Objective.: To test the hypothesis that using a mobile intraoperative computed tomography in combination with spinal navigation would result in better accuracy of lateral mass and pedicle screws between C3 and T5 levels, compared to cone-beam computed tomography and traditional 2D fluoroscopy. Summary of Background Data.: Use of spinal navigation associated with 3D imaging has been shown to improve accuracy of screw positioning in the cervico-thoracic region. However, use of iCT imaging compared to a cone-beam CT has not been fully investigated in these types of surgical interventions. Methods.: We retrospectively analyzed a series of patients who underwent posterior cervico-thoracic fixations using different intraoperative imaging systems in a single hospital. We identified three different groups of patients: Group A, operated under 2D-fluoroscopic guidance without navigation; Group B: O-arm guidance with navigation; Group C: iCT AIRO guidance with navigation. Primary outcome was the rate of accurately placed screws, measured on intra or postoperative CT scan with Neo et al. classification for cervical pedicles screws and Gertzbein et al. for thoracic pedicle screws. Screws in cervical lateral masses were evaluated according to a new classification created by the authors. Results.: Data on 67 patients and 495 screws were available. Overall screw accuracy was 92.8% (95.6% for lateral mass screws, 81.6% for cervical pedicle screws, and 90% for thoracic pedicle screws). Patients operated with iCT AIRO navigation had significantly fewer misplaced screws (2.4%) compared to 2D-fluoroscopic guidance (9.1%) and O-arm navigation (9.7%) (P = 0.0152). Accuracy rate of iCT navigation versus O-arm navigation was significantly higher (P = 0.0042), and there was no statistically significant difference in surgical time between the three Groups (P = 0.5390). Conclusion.: Use of high-quality CT associated with spinal navigation significantly improved accuracy of screw positioning in the cervico-thoracic region. Level of Evidence: 3.
24 October 2019 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Burst fractures are characterized by middle column disruption and may feature posterior wall retropulsion. Indications for treatment remain controversial. Recently introduced vertebral augmentation techniques using intravertebral distraction devices, such as vertebral body stents and SpineJack, could be effective in fracture reduction and fixation and might obtain central canal clearance through ligamentotaxis. This study assesses the results of armed kyphoplasty using vertebral body stents or SpineJack in traumatic, osteoporotic, and neoplastic burst fractures with respect to vertebral body height restoration and correction of posterior wall retropulsion. MATERIALS AND METHODS: This was a retrospective assessment of 53 burst fractures with posterior wall retropulsion and no neurologic deficit in 51 consecutive patients treated with armed kyphoplasty. Posterior wall retropulsion and vertebral body height were measured on pre- and postprocedural CT. Clinical and radiologic follow-up charts were reviewed. RESULTS: Armed kyphoplasty was performed as a stand-alone treatment in 43 patients, combined with posterior instrumentation in 8 and laminectomy in 4. Pre-armed kyphoplasty and post-armed kyphoplasty mean posterior wall retropulsion was 5.8 and 4.5 mm, respectively (P < .001), and mean vertebral body height was 10.8 and 16.7 mm, respectively (P < .001). No significant clinical complications occurred. Clinical and radiologic follow-up (1–36 months; mean, 8 months) was available in 39 patients. Three treated levels showed a new fracture during follow-up without neurologic deterioration, and no retreatment was deemed necessary. CONCLUSIONS: In the treatment of burst fractures with posterior wall retropulsion and no neurologic deficit, armed kyphoplasty yields fracture reduction, internal fixation, and indirect central canal decompression. In selected cases, it might represent a suitable minimally invasive treatment option, stand-alone or in combination with posterior stabilization.
Background: Around 20% of patients undergoing spinal fusion surgery have persistent back or leg pain despite surgery. Pain catastrophizing is the strongest psychological predictor for chronic postsurgical pain. Psychological variables are modifiable and could be target for intervention. However, randomized controlled trials evaluating the effectiveness of psychological interventions to reduce chronic pain and disability after spinal fusion in a population of patients with high preoperative pain catastrophizing scores are missing. The aim of our study is to examine whether an intervention targeting pain catastrophizing mitigates the risk of chronic postsurgical pain and disability. Our primary hypothesis is that targeted perioperative cognitive behavioral therapy decreases the risk of chronic postsurgical pain and disability after spinal fusion surgery in high catastrophizing patients. Methods: We will perform a two-center prospective, single-blind, randomized, controlled study comparing lumbar spinal fusion surgery outcome between 2 cohorts. Adult patients selected for lumbar spinal fusion with decompression surgery and a minimum score of 24 on the pain catastrophizing scale will be randomized with 1:1 allocation for either perioperative cognitive behavioral therapy (intervention group) or a perioperative education plus progressive exercise program (control group). Patients randomized to the intervention group will receive six individual sessions of cognitive behavioral therapy, two sessions before the operation and four after. Primary outcome is the Core Outcome Measures Index at 12 months. Secondary outcomes include pain, disability, depression and quality of life. Discussion: This is the first trial that evaluates the effectiveness of cognitive behavioral therapy as a perioperative tool to improve pain and disability after spinal fusion surgery in comparison with an educational/exercise control intervention, in patients with high levels of pain catastrophizing. If perioperative cognitive behavioral therapy proves to be effective, this might have important clinical implications, reducing the incidence of chronic postsurgical pain and improving outcome after spinal fusion surgery. Trial registration: Clinicaltrials (NCT03969602). Registered 31 May 2019,
13 September 2018 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Altered biomechanics or bone fragility or both contribute to spine instrumentation failure. Although revision surgery is frequently required, minimally invasive alternatives may be feasible. We report the largest to-date series of percutaneous fluoroscopically guided vertebral cement augmentation procedures to address feasibility, safety, results and a variety of spinal instrumentation failure conditions. MATERIALS AND METHODS: A consecutive series of 31 fluoroscopically guided vertebral augmentation procedures in 29 patients were performed to address screw loosening (42 screws), cage subsidence (7 cages), and fracture within (12 cases) or adjacent to (11 cases) the instrumented segment. Instrumentation failure was deemed clinically relevant when resulting in pain or jeopardizing spinal biomechanical stability. The main study end point was the rate of revision surgery avoidance; feasibility and safety were assessed by prospective recording of periprocedural technical and clinical complications; and clinical effect was measured at 1 month with the Patient Global Impression of Change score. RESULTS: All except 1 procedure was technically feasible. No periprocedural complications occurred. Clinical and radiologic follow-up was available in 28 patients (median, 16 months) and 30 procedures. Revision surgery was avoided in 23/28 (82%) patients, and a global clinical benefit (Patient Global Impression of Change, 5–7) was reported in 26/30 (87%) cases at 1-month follow-up, while no substantial change (Patient Global Impression of Change, 4) was reported in 3/30 (10%), and worsening status (Patient Global Impression of Change, 3), in 1/30 (3%). CONCLUSIONS: Our experience supports the feasibility of percutaneous vertebral augmentation in the treatment of several clinically relevant spinal instrumentation failure conditions, with excellent safety and efficacy profiles, both in avoidance of revision surgery and for pain palliation.