Mehdi Rafeie

Mehdi Rafeie

Auto-generated profile, based on publicly available information

Mehdi Rafeie

School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, New South Wales 2052, Australia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MRMehdi Rafeie
Mehdi Rafeie
JZJun Zhang
Jun Zhang
MAMohsen Asadnia
Mohsen Asadnia
WLWeihua Li
Weihua Li
Majid Ebrahimi WarkianiMajid Ebrahimi Warkiani
Majid Ebrahimi Warkiani
Blood and blood products are critical components of health care. Blood components perform distinct functions in the human body and thus the ability to efficiently fractionate blood into its individual components (i.e., plasma and cellular components) is of utmost importance for therapeutic and diagnostic purposes. Although conventional approaches like centrifugation and membrane filtration for blood processing have been successful in generating relatively pure fractions, they are largely limited by factors such as the required blood sample volume, component purity, clogging, processing time and operation efficiency. In this work, we developed a high-throughput inertial microfluidic system for cell focusing and blood plasma separation from small to large volume blood samples (1–100 mL). Initially, polystyrene beads and blood cells were used to investigate the inertial focusing performance of a single slanted spiral microchannel as a function of particle size, flow rate, and blood cell concentration. Afterwards, blood plasma separation was conducted using an optimised spiral microchannel with relatively large dimensions. It was found that the reject ratio of the slanted spiral channel is close to 100% for blood samples with haematocrit (HCT) values of 0.5% and 1% under an optimal flow rate of 1.5 mL min−1. Finally, through a unique multiplexing approach, we built a high-throughput system consisting of 16 spiral channels connected together, which can process diluted samples with a total flow rate as high as 24 mL min−1. The proposed multiplexed system can surmount the shortcomings of previously reported microfluidic systems for plasma separation and cell sorting in terms of throughput, yield and operation efficiency.

1 March 2018 in Bioresource Technology
Verified
Journal Article
Closed access
MSMaira S. Syed
Maira S. Syed
MRMehdi Rafeie
Mehdi Rafeie
DVDries Vandamme
Dries Vandamme
MAMohsen Asadnia
Mohsen Asadnia
RHRita Henderson
Rita Henderson
Majid Ebrahimi WarkianiMajid Ebrahimi Warkiani
Majid Ebrahimi Warkiani

2 June 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MSMaira Shakeel Syed
Maira Shakeel Syed
MRMehdi Rafeie
Mehdi Rafeie
RHRita Henderson
Rita Henderson
DVDries Vandamme
Dries Vandamme
MAMohsen Asadnia
Mohsen Asadnia
Majid Ebrahimi WarkianiMajid Ebrahimi Warkiani
Majid Ebrahimi Warkiani
The separation of micro-sized particles in a continuous flow is crucial part of many industrial processes, from biopharmaceutical manufacturing to water treatment. Conventional separation techniques such as centrifugation and membrane filtration are largely limited by factors such as clogging, processing time and operation efficiency. Microfluidic based techniques have been gaining great attention in recent years as efficient and powerful approaches for particle–liquid separation. Yet the production of such systems using standard micro-fabrication techniques is proven to be tedious, costly and have cumbersome user interfaces, which all render commercialization difficult. Here, we demonstrate the design, fabrication and evaluation based on CFD simulation as well as experimentation of 3D-printed miniaturized hydrocyclones with smaller cut-size for high-throughput particle/cell sorting. The characteristics of the mini-cyclones were numerically investigated using computational fluid dynamics (CFD) techniques previously revealing that reduction in the size of the cyclone results in smaller cut-size of the particles. To showcase its utility, high-throughput algae harvesting from the medium with low energy input is demonstrated for the marine microalgae Tetraselmis suecica. Final microalgal biomass concentration was increased by 7.13 times in 11 minutes of operation time using our designed hydrocyclone (HC-1). We expect that this elegant approach can surmount the shortcomings of other microfluidic technologies such as clogging, low-throughput, cost and difficulty in operation. By moving away from production of planar microfluidic systems using conventional microfabrication techniques and embracing 3D-printing technology for construction of discrete elements, we envision 3D-printed mini-cyclones can be part of a library of standardized active and passive microfluidic components, suitable for particle–liquid separation.

1 January 2017 in Biomicrofluidics
Verified
Journal Article
Open access
MRMehdi Rafeie
Mehdi Rafeie
MWMarcel Welleweerd
Marcel Welleweerd
AHAmin Hassanzadeh-Barforoushi
Amin Hassanzadeh-Barforoushi
MAMohsen Asadnia
Mohsen Asadnia
WOWouter Olthuis
Wouter Olthuis
Majid Ebrahimi WarkianiMajid Ebrahimi Warkiani
Majid Ebrahimi Warkiani
Mixing fluid samples or reactants is a paramount function in the fields of micro total analysis system (μTAS) and microchemical processing. However, rapid and efficient fluid mixing is difficult to achieve inside microchannels because of the difficulty of diffusive mass transfer in the laminar regime of the typical microfluidic flows. It has been well recorded that the mixing efficiency can be boosted by migrating from two-dimensional (2D) to three-dimensional (3D) geometries. Although several 3D chaotic mixers have been designed, most of them offer a high mixing efficiency only in a very limited range of Reynolds numbers (Re). In this work, we developed a 3D fine-threaded lemniscate-shaped micromixer whose maximum numerical and empirical efficiency is around 97% and 93%, respectively, and maintains its high performance (i.e., >90%) over a wide range of 1 < Re < 1000 which meets the requirements of both the μTAS and microchemical process applications. The 3D micromixer was designed based on two distinct mixing strategies, namely, the inducing of chaotic advection by the presence of Dean flow and diffusive mixing through thread-like grooves around the curved body of the mixers. First, a set of numerical simulations was performed to study the physics of the flow and to determine the essential geometrical parameters of the mixers. Second, a simple and cost-effective method was exploited to fabricate the convoluted structure of the micromixers through the removal of a 3D-printed wax structure from a block of cured polydimethylsiloxane. Finally, the fabricated mixers with different threads were tested using a fluorescent microscope demonstrating a good agreement with the results of the numerical simulation. We envisage that the strategy used in this work would expand the scope of the micromixer technology by broadening the range of efficient working flow rate and providing an easy way to the fabrication of 3D convoluted microstructures.

17 January 2018 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SSSamuel Sofela
Samuel Sofela
SSSarah Sahloul
Sarah Sahloul
MRMehdi Rafeie
Mehdi Rafeie
TKTaehong Kwon
Taehong Kwon
JHJongyoon Han
Jongyoon Han
Yong-Ak SongYong-Ak Song
Yong-Ak Song
In this study, we report the use of a high-throughput microfluidic spiral chip to screen out eggs from a mixed age nematode population, which can subsequently be cultured to a desired developmental stage. For the sorting of a mixture containing three different developmental stages, eggs, L1 and L4, we utilized a microfluidic spiral chip with a trapezoidal channel to obtain a sorting efficiency of above 97% and a sample purity (SP) of above 80% for eggs at different flow rates up to 10 mL min−1. The result demonstrated a cost-effective, simple, and highly efficient method for synchronizing C. elegans at a high throughput (∼4200 organisms per min at 6 mL min−1), while eliminating challenges such as clogging and non-reusability of membrane-based filtration. Due to its simplicity, our method can be easily adopted in the C. elegans research community.

1 May 2019 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
MRMehdi Rafeie
Mehdi Rafeie
SHShahin Hosseinzadeh
Shahin Hosseinzadeh
RTRobert A. Taylor
Robert A. Taylor
MWMajid Ebrahimi Warkiani
Majid Ebrahimi Warkiani
Inertial microfluidics represents a powerful new tool for accurately positioning cells and microparticles within fluids for a variety of biomedical, clinical, and industrial applications. In spite of enormous advancements in the science and design of these devices, particularly in curved microfluidic channels, contradictory experimental results have confounded researchers and limited progress. Thus, at present, a complete theory which describes the underlying physics is lacking. We propose that this bottleneck is due to one simple mistaken assumption—the locations of inflection points of the Dean velocity profile in curved microchannels are not fixed, but can actually shift with the flow rate. Herein, we propose that the dynamic distance (δ) between the real equilibrium positions and their nearest inflection points can clearly explain several (previously) unexplained phenomena in inertial microfluidic systems. More interestingly, we found that this parameter, δ, is a function of several geometric and operational parameters, all of which are investigated (in detail) here with a series of experiments and simulations of different spiral microchannels. This key piece of understanding is expected to open the door for researchers to develop new and more effective inertial microfluidic designs.