Oğuz Aslan

Oğuz Aslan

Auto-generated profile, based on publicly available information

Oğuz Aslan

Department of Radiology, Kayseri City Training and Research Hospital, Kayseri, Turkey

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2026 in Irish Journal of Medical Science (1971 -)
Verified
Journal Article
Closed access
PDF file
SKSinan Karatoprak
Sinan Karatoprak
MBMustafa Bilgili
Mustafa Bilgili
OAOğuz Aslan
Oğuz Aslan
GTGamze Türk
Gamze Türk
NKNur Betül Karatoprak
Nur Betül Karatoprak
UAUğur Aydemir
Uğur Aydemir

12 November 2026 in British Journal of Radiology
Verified
Journal Article
Closed access
MBMustafa Bilgili
Mustafa Bilgili
SKSinan Karatoprak
Sinan Karatoprak
OAOğuz Aslan
Oğuz Aslan
GTGamze Türk
Gamze Türk
EAEbru Akay
Ebru Akay
Objectives: To compare the diagnostic performance and procedural efficiency of American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS), European Thyroid Imaging Reporting and Data System (EU-TIRADS), and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) in ≤ 10 mm nodules using Bethesda cytology as the reference standard. Methods: This retrospective study included 998 nodules ≤10 mm undergoing ultrasound-guided fine-needle aspiration biopsy (FNAB). Primary analyses included Bethesda II (negative) and Bethesda V–VI (positive) nodules excluding Bethesda I/III/IV, yielding 604 nodules (540 negative; 64 positive). Categories 1–3 were considered low risk and 4–5 high risk under a harmonized threshold Diagnostic performance and classification patterns were compared. Results: K-TIRADS showed the numerically highest sensitivity (93.8%) and negative predictive value (NPV) (97.9%), although sensitivity did not differ significantly between systems, with lower specificity (35.4%) and accuracy (41.6%).EU-TIRADS showed intermediate performans (sensitivity 68.8%, specificity 73.7%, accuracy 73.2%). ACR TI-RADS achieved the highest specificity (83.3%) and accuracy (81.0%) with lower sensitivity (60.9%). Low-risk classification rates were 78.6% (ACR), 69.2% (EU), and 32.3% (K) of nodules; false-positive high-risk classifications among Bethesda II nodules were 16.7%, 26.3%, and 64.6%, respectively. Conclusion: In ≤ 10 mm nodules, the three systems demonstrated distinct diagnostic and classification profiles under a harmonized TR4–5 threshold, with different trade-offs between sensitivity and specificity. Advances in knowledge: Applying a harmonized TR4–5 threshold in ≤ 10 mm nodules reveals substantially differences in classification patterns among the three systems, demonstrating that they are not interchangeable under a uniform risk threshold.

20 April 2025 in Journal of Clinical Ultrasound
Verified
Journal Article
Closed access
SKSinan Karatoprak
Sinan Karatoprak
OAOğuz Aslan
Oğuz Aslan
MBMustafa Bilgili
Mustafa Bilgili
GTGamze Türk
Gamze Türk
HDHüseyin Murat Demirbaş
Hüseyin Murat Demirbaş
SSSaliha Sunkak
Saliha Sunkak