9 October 2019 in Journal of Neurotrauma
The aim of this study is to determine the strength and accuracy of diffusion tensor imaging (DTI) parameters to predict neurological injury and recovery in adult cervical spinal cord injury (SCI). DTI magnetic resonance imaging (MRI) was performed on 23 acute cervical SCI patients within 12 h after injury and on 45 controls utilizing a rapid DTI sequence (∼5 min). Neurological assessments were conducted from within 24 h of injury up to 6 months utilizing detailed International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) examinations. Spearman correlation and receiver operating characteristic (ROC) analysis were used to identify relationships between the DTI parameters at the lesion epicenter and adjacent regions, with injury severity and recovery. In proximity to the anatomical injury (within one level above and below epicenter), there was significant reduction in fractional anisotropy (FA), and elevation in mean diffusivity (MD) and radial diffusivity (RD). DTI values measured one level rostral to the injury epicenter showed stronger correlations with multiple clinical features at several time-points. Area under the curve (AUC) obtained from ROC analysis showed FA (AUC = 0.77) measured at lesion epicenter, and FA (0.83), MD (0.76), and RD (0.83) values measured immediately rostral (one level above) to epicenter discriminate injury severity. Further, MD (0.78) measured at lesion epicenter, and MD (0.79) and RD (0.74) values measured immediately rostral to epicenter discriminate neurological recovery. DTI indices measured immediately rostral to the anatomical level of injury consistently showed better correlation (moderate to strong) and accuracy in predicting neurological injury (FA, r = −0.51 and RD, r = 0.54) and recovery (MD, r = −0.51) than indices measured at the epicenter. There was weak to moderate correlation of all measures at lesion epicenter in predicting neurological injury (FA: r = −0.48; MD: r = 0.23; RD: r = 0.34; axial diffusivity [AD]: r = 0.02) and recovery (FA: r = 0.27; MD: r = −0.44; RD: r = −0.35; AD: r = −0.34).
14 June 2018 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: The zonally magnified oblique multislice EPI (ZOOM-EPI) diffusion-weighted sequence has been visually shown to provide superior MR diffusion image quality compared with the full-FOV single-shot EPI sequence (non-ZOOM-EPI) in the adult cervical spinal cord. The purpose of this study was to examine the diffusion tensor imaging indices in the normal human cervical spinal cord between ZOOMED and non-ZOOMED DTI acquisitions and determine whether DTI values are comparable between direct and indirect age-matched groups. MATERIALS AND METHODS: Fifty-four subjects 23–58 years of age (9 direct age-matched and 45 indirect age-matched) were scanned using a 1.5T scanner. Diffusion tensor indices including fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity were generated from the DTI dataset. These DTI values were calculated for both ZOOM and non-ZOOM acquisitions and compared at each intervertebral disc level. The variability of the DTI values for ZOOM and non-ZOOM sequences was measured using a coefficient of variation within direct and indirect age-matched controls. RESULTS: The mean diffusivity, axial diffusivity, and radial diffusivity values obtained along the cervical spinal cord in the age-matched controls showed a significant decrease using the ZOOM sequence (P = .05, P = .002, and P < .001). Mean fractional anisotropy showed a significant increase (P = .04) using the ZOOM sequence. The indirect age-matched controls showed a statistically significant increase in fractional anisotropy (P = .03) and a decrease in mean diffusivity (P = .002), axial diffusivity (P < .001), and radial diffusivity (P = .002) using the ZOOM sequence. Less variability has been shown in DTI using the ZOOM sequence compared with the non-ZOOM sequence in both direct and indirect age groups. The ZOOM sequence exhibited higher SNR (SNRZOOM = 22.84 ± 7.59) compared with the non-ZOOM sequence (SNRnon-ZOOM = 19.7 ± 7.05). However, when we used a 2-tailed t test assuming unequal variances, the ZOOM sequence did not demonstrate a statistically significant increase. CONCLUSIONS: ZOOM DTI acquisition methods provide superior image quality and precision over non-ZOOM techniques and are recommended over conventional full-FOV single-shot EPI DTI for clinical applications in cervical spinal cord imaging.