Anton Sondermann

Anton Sondermann

Auto-generated profile, based on publicly available information

Anton Sondermann

Neurologeriatrie Department (A.S.), Christian-Albrechts-Universität zu Kiel, Kiel, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JSJoao Andre Sousa
Joao Andre Sousa
ASAnton Sondermann
Anton Sondermann
SBSara Bernardo-Castro
Sara Bernardo-Castro
RVRicardo Varela
Ricardo Varela
Helena DonatoHelena Donato
Helena Donato
JSJoão Sargento-Freitas
João Sargento-Freitas
BACKGROUND: The optimal imaging method for detecting distal medium vessel occlusions (DMVOs) remains undefined. PURPOSE: The objective of this study is to compare the diagnostic performance of CTA with CTP in detecting DMVOs. DATA SOURCES: We searched PubMed, EMBASE, Web of Science Core Collection, and Cochrane Central Register of Controlled Trials up to March 31, 2023 (PROSPERO: CRD42022344006). STUDY SELECTION: A total of 12 studies reporting accuracy values of CTA and/or CTP were included, comprising 2607 patients with 479 cases (18.3%) of DMVOs. DATA ANALYSIS: Pooled sensitivity and specificity of both imaging methods were compared using a random-effects model. Subgroup analyses were performed based on the technique used in CTA (multi or single-phase) and the subtype of DMVOs (M2-only vs. M2 and other DMVOs). We applied Quality Assessment of Diagnostic Accuracy (QUADAS-2) tool and Grading of Recommendations, Assessment, Development and Evaluation (GRADE) quality assessment criteria. DATA SYNTHESIS: CTA demonstrated significantly lower sensitivity compared to CTP in detecting DMVOs [0.74, 95%CI (0.63–0.82) vs. 0.89, 95% CI (0.82–0.93), P < 0.01]. When subgrouped into single-phase and multi-phase CTA, multi-phase CTA exhibited higher sensitivity for DMVO detection than single-phase CTA [0.91, 95%CI (0.85–0.94) vs. 0.64, 95%CI (0.56–0.71), P < .01], while reaching similar levels to CTP. The sensitivity of single-phase CTA substantially decreased when extending from M2 to other non-M2 DMVOs [0.74, 95%CI (0.63–0.83) vs. 0.61, 0.95%CI (0.53–0.68), P = .02]. LIMITATIONS: We identified an overall high risk of bias and low quality of evidence, attributable to the design and reference standards of most studies. CONCLUSIONS: Our findings highlight a significantly lower sensitivity of single-phase CTA compared to multi-phase CTA and CTP in diagnosing DMVOs.