Rajakumar Nagarajan

Rajakumar Nagarajan

Auto-generated profile, based on publicly available information

Rajakumar Nagarajan

Human Magnetic Resonance Center, Institute for Applied Life Sciences University of Massachusetts Amherst Amherst MA USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2013 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
GVGaurav Verma
Gaurav Verma
HHHari Hariharan
Hari Hariharan
RNRajakumar Nagarajan
Rajakumar Nagarajan
RNRavi P.R. Nanga
Ravi P.R. Nanga
EDEdward J. Delikatny
Edward J. Delikatny
HPHarish Poptani
Harish Poptani
Purpose: To evaluate the utility of two‐dimensional (2D) Localized Correlated Spectroscopy (L‐COSY) in metabolic profiling of the human brain at 7 Tesla (T).Materials and Methods: The 2D L‐COSY sequence was implemented at 7T and its reliability was assessed by test–retest studies of a metabolite phantom and a healthy volunteer. L‐COSY data were acquired from the occipital lobe of healthy subjects (n = 6; all male; age, 30–72 years) to assess intersubject variability. Additionally, two subjects underwent scans from the parieto‐occipital region, basal ganglia, frontal lobe or dorsolateral prefrontal cortex to test the versatility of L‐COSY in studying differing anatomy. Integral/volume measurements of L‐COSY spectra were used to estimate normalized metabolite‐to‐creatine concentrations.Results: Phantom test–retest studies revealed coefficients of variation (CVs) of 3–20% for most metabolites. Human 2D L‐COSY spectra permitted detection of several metabolite resonances from multiple locations and inter‐subject variation studies demonstrated CVs of 4–26%. Cross‐peaks from gamma‐aminobutyric acid (GABA), isoleucine (Ile), lysine (Lys) and Ethanolamine (Eth) were quantified, which are not readily resolvable with conventional one‐dimensional (1D) MR spectroscopy.Conclusion: 2D L‐COSY at 7T demonstrated improved sensitivity in detecting additional metabolites with reliability comparable to established techniques at lower fields, which may aid in the metabolic assessment of diseased states. J. Magn. Reson. Imaging 2014;40:1319–1327. © 2013 Wiley Periodicals, Inc.

1 January 2013 in Magnetic Resonance Insights
Verified
Journal Article
Open access
RNRajakumar Nagarajan
Rajakumar Nagarajan
DMDaniel Jason Aaron Margolis
Daniel Jason Aaron Margolis
SRSteven S. Raman
Steven S. Raman
DODavid Ouellette
David Ouellette
MSManoj K. Sarma
Manoj K. Sarma
michael albert thomasmichael albert thomas
michael albert thomas
Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array “receive” coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal MR imaging and proton (1H) MRSI were included in this study. Immediately after the endorectal MRSI scan, the PCa patients were scanned with the external phased array coil. The endorectal coil-detected metabolite ratio [(Ch+Cr)/Cit] was significantly higher in cancer locations (1.667 ± 0.663) compared to non-cancer locations (0.978 ± 0.420) ( P < 0.001). Similarly, for the external phased array, the ratio was significantly higher in cancer locations (1.070 ± 0.525) compared to non-cancer locations (0.521 ± 0.310) ( P < 0.001). The sensitivity and accuracy of cancer detection were 81% and 78% using the endorectal ‘receive’ coil, and 69% and 75%, respectively using the external phased array ‘receive’ coil.

1 February 2024 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Open access
MBMiles F. Bartlett
Miles F. Bartlett
LFLiam F Fitzgerald
Liam F Fitzgerald
RNRajakumar Nagarajan
Rajakumar Nagarajan
JKJane A. Kent
Jane A. Kent
Human skeletal muscle oxidative capacity can be quantified non-invasively using 31-phosphorus magnetic resonance spectroscopy (31P-MRS) to measure the rate constant of phosphocreatine (PCr) recovery ( kPCr) following contractions. In the quadricep muscles, several studies have quantified kPCr following 24–30 s of sustained maximal voluntary isometric contraction (MVIC). This approach has the advantage of simplicity but is potentially problematic because sustained MVICs inhibit perfusion, which may limit muscle oxygen availability or increase the intracellular metabolic perturbation, and thus affect kPCr. Alternatively, dynamic contractions allow reperfusion between contractions, which may avoid limitations in oxygen delivery. To determine whether dynamic contraction protocols elicit greater kPCr than sustained MVIC protocols, we used a cross-sectional design to compare quadriceps kPCr in 22 young and 11 older healthy adults following 24 s of maximal voluntary: (1) sustained MVIC and (2) dynamic (MVDC; 120°·s−1, 1 every 2 s) contractions. Muscle kPCr was ∼20% lower following the MVIC protocol compared with the MVDC protocol ( p ≤ 0.001), though this was less evident in older adults ( p = 0.073). Changes in skeletal muscle pH ( p ≤ 0.001) and PME accumulation ( p ≤ 0.001) were greater following the sustained MVIC protocol, and pH ( p ≤ 0.001) and PME ( p ≤ 0.001) recovery were slower. These results demonstrate that (i) a brief, sustained MVIC yields a lower value for skeletal muscle oxidative capacity than an MVDC protocol of similar duration and (ii) this difference may not be consistent across populations (e.g., young vs. old). Thus, the potential effect of contraction protocol on comparisons of kPCr in different study groups requires careful consideration in the future.

1 January 2010 in Magnetic Resonance Insights
Verified
Journal Article
Open access
RNRajakumar Nagarajan
Rajakumar Nagarajan
SRSaadallah Ramadan
Saadallah Ramadan
michael albert thomasmichael albert thomas
michael albert thomas
The purpose of the study was to demonstrate the J-coupling connectivity network between the amide, aliphatic, and aromatic proton resonances of metabolites in human brain using two-dimensional (2D) localized correlated spectroscopy (L-COSY). Two different global water suppression techniques were combined with L-COSY, one before and another after localizing the volume of interest (VOI). Phantom solutions containing several cerebral metabolites at physiological concentrations were evaluated initially for sequence optimization. Nine healthy volunteers were scanned using a 3T whole body MRI scanner. The VOI for 2D L-COSY was placed in the right occipital white/gray matter region. The 2D cross and diagonal peak volumes were measured for several metabolites such as N-acetyl aspartate (NAA), creatine (Cr), free choline (Ch), glutamate/glutamine (Glx), aspartate (Asp), myo-inositol (mI), GABA, glutathione (GSH), phosphocholine (PCh), phosphoethanolamine (PE), tyrosine (Tyr), lactate (Lac), macromolecules (MM) and homocarnosine (Car). Using the pre-water suppression technique with L-COSY, the above mentioned metabolites were clearly identifiable and the relative ratios of metabolites were calculated. In addition to detecting multitude of aliphatic resonances in the high field region, we have demonstrated that the amide and aromatic resonances can also be detected using 2D L-COSY by pre water suppression more reliably than the post-water suppression.

24 May 2026 in The Journal of Physiology
Verified
Journal Article
Open access
MEMuhammet Enes Erol
Muhammet Enes Erol
AMAlexs A. Matias
Alexs A. Matias
CSCorinna F. Serviente
Corinna F. Serviente
SDStephen T. Decker
Stephen T. Decker
RNRajakumar Nagarajan
Rajakumar Nagarajan
GLGwenael Layec
Gwenael Layec
Mitochondrial oxygen (O 2 ) affinity is a fundamental determinant of oxidative phosphorylation capacity, which has yet to be directly measured in human skeletal muscle in vivo . To determine the apparent mitochondrial O 2 affinity (i.e. P 50 ) of the skeletal muscle, we used proton‐magnetic resonance spectroscopy ( 1 H‐MRS) of deoxymyoglobin (dMb) during a circulatory occlusion of the lower limb to simultaneously quantify intracellular partial pressure of O 2 (i ) and resting tissue‐specific O 2 consumption () in the gastrocnemius muscle of sedentary young adults. Under these resting conditions, the –i relationship conformed to a Michaelis–Menten kinetics model (goodness of fit: r 2 = 0.84 ± 0.13). The estimated V ss , reflecting basal metabolic rate, reached 0.20 ± 0.06 mM min −1 , and the apparent mitochondrial P 50 was 0.50 ± 0.38 mmHg. V ss and P 50 were positively correlated ( r = 0.85, P = 0.0009). This strong correlation remained after log transformation ( r = 0.82, P = 0.0020). These results, obtained in human muscles in vivo , demonstrate that mitochondrial respiration exhibits a very high O 2 affinity ( P 50 ≈ 0.5 mmHg). In addition, it quantitatively identifies the range across which oxidative phosphorylation in the skeletal muscle is O 2 ‐independent (resting i under physiological conditions) or becomes O 2 ‐sensitive (severe exercise and hypoxia). Moreover, the finding that muscle respiratory flux was associated with the apparent mitochondrial O 2 affinity suggests additional regulatory mechanisms within the respiratory chain to fine‐tune oxidative phosphorylation to muscle ATP demand even at rest. This study provides a robust quantitative framework for interpreting in vivo respiratory control in both health and disease. image Key points: Mitochondrial oxygen affinity ( P 50 ) is central to oxidative phosphorylation, yet has not been directly quantified in human skeletal muscle in vivo . Using deoxymyoglobin 1 H‐MRS during 8 min of lower‐limb ischaemia, we simultaneously measure intracellular partial pressure of O 2 (i ) and resting tissue‐specific O 2 consumption () in the resting gastrocnemius of healthy young adults. The – relationship followed Michaelis–Menten kinetics, yielding a V ss of 0.20 mM min −1 and an apparent mitochondrial P 50 of 0.50 mmHg, indicating very high O 2 affinity. Resting apparent mitochondrial P 50 was far below previously reported i (∼34 mmHg), indicating a wide O 2 ‐independent range and identifying conditions (severe hypoxia, high‐intensity exercise) in which oxidative phosphorylation becomes O 2 ‐sensitive. V ss and P 50 were positively correlated ( r = 0.85), suggesting in vivo coupling between respiratory flux and oxygen affinity and providing a potential quantitative framework for interpreting mitochondrial respiratory control in health and disease.

3 August 2023
Verified
Conference Paper
Closed access
JGJoseph Gordon
Joseph Gordon
NRNicholas Remillard
Nicholas Remillard
LALuke Arieta
Luke Arieta
RNRajakumar Nagarajan
Rajakumar Nagarajan
BDBruce Damon
Bruce Damon
JKJane Kent
Jane Kent
The purpose of this work was to investigate the associations between skeletal muscle function and markers of fat content, diffusivity, and architecture. Combining MR techniques that measure muscle structure in vivo with muscle strength measures can elucidate mechanisms other than muscle size that may contribute to functional impairments. This study identified variables (e.g., fascicle length, muscle curvature, pennation angle, fat fraction) that are worthy of investigation in conjunction with functional parameters in future research, and highlighted assessment of muscle function across various contraction types and velocities.