Hongli Gao

Hongli Gao

Auto-generated profile, based on publicly available information

Hongli Gao

Department of Physiology and Pathophysiology, School of Medicine, Xi’an Jiaotong University, Xi’an, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in Cardiovascular Toxicology
Verified
Journal Article
Closed access
PDF file
HWHanxue Wu
Hanxue Wu
QSQi Sun
Qi Sun
SYShenglan Yuan
Shenglan Yuan
JWJiawei Wang
Jiawei Wang
FLFanni Li
Fanni Li
JXJiaxi Xu
Jiaxi Xu

6 March 2018 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
CLChengyong Li
Chengyong Li
YZYu Zhao
Yu Zhao
LHLei He
Lei He
RMRijian Mo
Rijian Mo
HGHongli Gao
Hongli Gao
GZGuigen Zhang
Guigen Zhang
A mussel-inspired new interfacial ionic rectification device is fabricated using porous anodic alumina nanochannels and graphene oxide via dopamine polymerization. In addition, the rectification mechanism is elucidated based on the principles of physics and thermodynamics via finite element simulation and the results show that the interface distance and surface charge play a vital role in ion transport.

1 May 2014 in China Journal of Chinese Materia Medica
Verified
Journal Article
Closed access
HGHong-Li Gao
Hong-Li Gao
XLXiao rong Li
Xiao rong Li
LYLiang-Chun Yan
Liang-Chun Yan
JZJunning Zhao
Junning Zhao
Vibrio fischeri CS234 was used to establish and optimize microtox assay system, laying a foundation for the application of this method in comprehensive acute toxicity test of traditional Chinese medicine (TCM) injections. Firstly, the Plackett-Burman method was carried out to optimize the factors which would affect Vibrio fischeri CS234 luminescence. Secondly, ZnSO4•7H2O was chosen as reference substance to establish its reaction system with quality control samples. The optimal luminescence conditions were achieved as follows: ①At a temperature of (15±1) ℃, Vibrio fischeri CS234 lyophilized powders were balanced for 15 min, then, 1 mL resuscitation fluid was added and blended for 10 min. 100 μL bacteria suspension was taken to measure the initial luminescence intensity, and then 1 mL resuscitation fluid or test sample was immediately added; after reaction for 10 min, corresponding luminescence intensity was measured again. Resuscitation diluent, osmotic pressure regulator and ZnSO4•7H2O stock solution showed no interference to the determination of Vibrio fischeri CS234 luminescence intensity, so this method was of good specificity. The within-and between-batch precisions of quality controls and the lower limit of quantification (LLOQ) samples were <5% and <10% respectively, while the accuracy ranged between 85.8% and 103.2%. The standard curve equation of ZnSO4•7H2O ranged from 3.86 mg•L⁻¹ to 77.22 mg•L⁻¹ (final concentrations) was y=21.78lnx-15.14, R2=0.998; meanwhile, IC₅₀ of ZnSO4•7H2O to Vibrio fischeri CS234 was 19.90 mg•L⁻¹. ZnSO4•7H2O stock solution and its quality controls were continuously investigated for 120 h and 8 h respectively, and their RSD was lower than 2%, indicating stability at room temperature and 4 ℃ storage conditions. Between pH 4.5-8.0, luminescence intensity of Vibrio fischeri CS234 was controlled within ±10%, and such pH value range could meet the testing needs of the vast majority of traditional Chinese medicine injections. The Vibrio fischeri strain CS234 assay system was specific, stable, sensitive, accurate and adaptable after optimization, so it was suitable for the comprehensive acute toxicity assessment of TCM injections.