Hüseyin Ünsal Erçelik

Hüseyin Ünsal Erçelik

Auto-generated profile, based on publicly available information

Hüseyin Ünsal Erçelik

Ankara Bilkent City Hospital, 06800 Ankara, Türkiye

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MSMuhammet Fethi Sağlam
Muhammet Fethi Sağlam
EUEmrah Uguz
Emrah Uguz
KEKemal Eşref Erdogan
Kemal Eşref Erdogan
HEHüseyin Ünsal Erçelik
Hüseyin Ünsal Erçelik
Murat YUCELMurat YUCEL
Murat YUCEL
EŞErol Şener
Erol Şener
Objective: Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. Methods: A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases. Metallic valves were initially implanted in all patients. Interventions included pannus cleaning in suitable cases and valve replacement when necessary, with the replacement being either metallic and biological based on clinical indications. Preoperative and postoperative ECG rhythms, left ventricular ejection fraction (LVEF) values, and gradient measurements were evaluated across patient groups. Results: No significant difference was found in time since initial surgery across valve types (p = 0.67), except in mitral valves, where time was longer in the replacement group (p = 0.02). Maximum gradients were higher in the pannus cleaning group for mitral valves (p = 0.03), while overall gradient values showed no significant differences. Postoperative left ventricular ejection fraction improved significantly in all groups (p < 0.001). Conclusions: The findings highlight the importance of timely intervention in managing stuck prosthetic valves, which are associated with severe hemodynamic compromise and embolic risk. Pannus cleaning emerged as a viable alternative in selected cases where the obstruction was localized, with the valve structure otherwise intact. Biological valve replacements demonstrated superior rhythm stabilization in this study, although definitive conclusions are constrained by the minimal sample size (n = 2). Future research should focus on expanding sample sizes and incorporating comprehensive preoperative analyses to better inform surgical and clinical management strategies.

7 March 2025 in Turkish Journal of Vascular Surgery
Verified
Journal Article
Open access
PDF file
MSMuhammet Fethi Sağlam
Muhammet Fethi Sağlam
EUEmrah Uguz
Emrah Uguz
KEKemal Eşref Erdoğan
Kemal Eşref Erdoğan
HEHuseyin Unsal Ercelik
Huseyin Unsal Ercelik
Murat YUCELMurat YUCEL
Murat YUCEL
ESErol Sener
Erol Sener
Aim: Aortic ruptures are critical vascular emergencies with high mortality rates, typically involving the thoracic and abdominal regions. This study aims to evaluate the clinical outcomes of Thoracic Endovascular Aortic Repair (TEVAR) and Endovascular Aneurysm Repair (EVAR) procedures in patients with ruptured thoracic and abdominal aortic pathologies, focusing on mortality, morbidity, and complications.Material and Methods: This retrospective, single-center study included 32 patients treated with endovascular interventions for ruptured aortic pathologies between 2019 and 2024. Fourteen patients with thoracic aortic rupture received TEVAR, while eighteen with abdominal aortic rupture underwent EVAR. The causes of rupture were classified as aortic transection (due to trauma), type-3 dissection, aneurysm, pseudoaneurysm, aorto-enteric fistula, and iatrogenic perforation. Demographic and clinical data, procedural details, and post-operative outcomes were collected and analyzed. Results: The primary causes of rupture included aortic transection (50%) in the TEVAR group and aneurysm (56.2%) in the EVAR group. Mortality rates were 14.3% in the TEVAR group and 27.8% in the EVAR group, while morbidity rates were 7.1% and 16.7%, respectively. Intensive care unit (ICU) and ward stays were significantly longer in the TEVAR group. Follow-up imaging showed normal results in 100% of TEVAR patients and in 88.9% of EVAR patients; endoleak was observed in 11.1% of the EVAR group (p<0.05). In the logistic regression analysis, the presence of complications was identified as a significant risk factor for mortality (OR=3.06, 95% CI: 1.04–8.97; p=0.04).Conclusion: TEVAR and EVAR are effective endovascular treatment modalities that provide high efficacy and safety in managing ruptured aortic pathologies, especially in emergency settings. The capability to perform hybrid procedures promptly in urgent cases underscores the adaptability and rapid applicability of endovascular therapies. Despite the inherent challenges of ruptured aortic pathologies, our study emphasizes the clinical importance of TEVAR in thoracic and EVAR in abdominal aortic ruptures, offering valuable insights that enhance the current literature.

27 March 2025 in Konuralp Tip Dergisi
Verified
Journal Article
Closed access
MSMuhammet Fethi Sağlam
Muhammet Fethi Sağlam
EUEmrah Uguz
Emrah Uguz
KEKemal Eşref Erdoğan
Kemal Eşref Erdoğan
HEHüseyin Ünsal Erçelik
Hüseyin Ünsal Erçelik
Murat YUCELMurat YUCEL
Murat YUCEL
ESErol Sener
Erol Sener
Objective: This study aims to evaluate the ability of GPT-3.5 and GPT-4 to provide accurate, comprehensible, and clinically relevant responses to common patient questions about coronary bypass surgery. Method: A cross-sectional study was conducted at Ankara Yıldırım Beyazıt University Bilkent City Hospital with 80 cardiovascular surgery specialists. Participants rated the responses of GPT-3.5 and GPT-4 to 10 common patient questions about coronary bypass surgery based on four criteria: accuracy, understandability, clinical appropriateness, and overall evaluation. Statistical analysis included independent t-tests, Cronbach’s Alpha reliability analysis, and Cohen’s d effect size calculation. Results: GPT-4 significantly outperformed GPT-3.5 across all metrics. The mean scores for GPT-4 were higher in accuracy (3.02 vs. 1.77), understandability (2.99 vs. 1.81), clinical appropriateness (2.96 vs. 1.78), and overall evaluation (2.98 vs. 1.77) (p

26 February 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
MSMuhammet Fethi Sağlam
Muhammet Fethi Sağlam
EUEmrah Uguz
Emrah Uguz
KEKemal Eşref Erdogan
Kemal Eşref Erdogan
HEHüseyin Ünsal Erçelik
Hüseyin Ünsal Erçelik
Murat YUCELMurat YUCEL
Murat YUCEL
EŞErol Şener
Erol Şener
Background: Aortic stenosis (AS) is one of the most common valvular heart diseases, particularly in the elderly, with a prevalence of approximately 3% in individuals over 75 years of age. Aortic valve replacement (AVR) remains the standard treatment, yet postoperative hemodynamic assessment is often complicated by variations in prosthetic valve size, left ventricular ejection fraction (LVEF), effective orifice area (EOA), and body surface area (BSA). These factors significantly influence prosthetic valve function and contribute to patient–prosthesis mismatch (PPM), which has been associated with worse clinical outcomes. Traditional transvalvular gradient measurements often fail to account for these patient-specific variables. This study introduces a novel approach to standardized gradient calculations, aiming to enhance the accuracy and comparability of prosthetic valve assessments. Methods: A retrospective analysis was conducted on 115 patients who underwent mechanical AVR at a single center. Patients were categorized into three groups based on the prosthetic valve type: St. Jude Medical (SJM) HP (n = 31); SJM Regent (n = 54); and those who underwent aortic root enlargement (ARE) (n = 30). Preoperative and postoperative transthoracic echocardiography (TTE) was performed to measure conventional and standardized transvalvular gradients. Four novel standardized gradient calculations were developed to adjust for individual hemodynamic differences, improving the accuracy of prosthetic valve function assessment. Results: Standardized gradient calculations demonstrated significant differences between prosthesis types. Postoperative standardized gradients were significantly higher in the SJM HP group compared to the SJM Regent and aortic-root-enlargement groups (p < 0.001, p < 0.05). The lowest standardized gradients were observed in patients who received the SJM Regent prostheses (p < 0.05). Although conventional measurements showed no significant differences, standardized calculations revealed that patients with 19 mm prostheses exhibited significantly higher transvalvular gradients than those with 21 mm prostheses (p < 0.05), emphasizing the clinical importance of prosthesis size in postoperative hemodynamics. Conclusions: Standardized gradient calculations provide a more objective, reliable, and patient-specific assessment of prosthetic valve function by minimizing interpatient variability. This approach improves the detection of patient–prosthesis mismatch and optimizes postoperative hemodynamic evaluation, potentially leading to better prosthesis selection and surgical decision-making. However, further validation is required in larger cohorts before these methods can be widely adopted into clinical practice. Future studies should assess their impact on long-term clinical outcomes, including left ventricular remodeling and patient survival.

17 March 2025 in Online Türk Sağlık Bilimleri Dergisi
Verified
Journal Article
Open access
PDF file
MSMuhammet Fethi Sağlam
Muhammet Fethi Sağlam
EUEmrah Uguz
Emrah Uguz
KEKemal Eşref Erdoğan
Kemal Eşref Erdoğan
HEHüseyin Ünsal Erçelik
Hüseyin Ünsal Erçelik
Murat YUCELMurat YUCEL
Murat YUCEL
ESErol Sener
Erol Sener
Objective: This study aimed to assess the impact of surgeons' experience (10–20 years vs. over 20 years) on clinical outcomes in coronary artery bypass grafting (CABG) surgeries, considering the multidisciplinary nature of cardiovascular surgery and the critical role of experience in influencing mortality, morbidity, and complications. Materials and Methods: A retrospective analysis was conducted, including 201 patients who underwent elective or emergency CABG between 2019 and 2024 at a single tertiary center. Patients were grouped based on the experience level of their surgeons. Demographic, intraoperative, and postoperative data were collected from hospital records. Results: Patients operated on by surgeons with over 20 years of experience had significantly higher rates of hypertension (83% vs. 70.3%; p=0.033) but showed no significant differences in mortality (3% vs. 2%; p=0.170) or complication rates (7% vs. 9.9%; p=0.460). Intraoperative parameters, such as cross-clamp time and cardiopulmonary bypass time, did not differ significantly between the groups (p>0.05). Weak positive correlations were found between cross-clamp time and postoperative ICU stay (r=0.189; p=0.007), as well as cardiopulmonary bypass time and ICU stay (r=0.205; p=0.003). Conclusions: Surgeons' experience levels influence certain clinical outcomes, particularly in managing high-risk patients. However, mortality and complication rates appear to depend more on multidisciplinary care and standardized protocols than on individual experience. Future studies should explore these dynamics across broader patient populations and different surgical procedures to optimize cardiovascular surgical practices.

16 December 2024 in Sakarya Medical Journal
Verified
Journal Article
Open access
PDF file
MSMuhammet Fethi Sağlam
Muhammet Fethi Sağlam
EUEmrah Uguz
Emrah Uguz
KEKemal Eşref Erdoğan
Kemal Eşref Erdoğan
HEHüseyin Ünsal Erçelik
Hüseyin Ünsal Erçelik
Murat YUCELMurat YUCEL
Murat YUCEL
ESErol Sener
Erol Sener
Objective: This study aimed to investigate the impact of preoperative right ventricular (RV) function on postoperative outcomes such as mortality, reoperation rates, valve size, and other clinical variables in patients undergoing tricuspid valve surgery. Methods: This retrospective study included 100 patients who underwent tricuspid valve surgery. Patients were categorized into four groups based on preoperative RV function: normal, mildly depressed, moderately depressed, and severely depressed. RV function was assessed using echocardiographic parameters, including tricuspid annular plane systolic excursion (TAPSE), tissue Doppler imaging (TDI), mean pulmonary artery pressure (MPAB), and valve size. Postoperative outcomes, including mortality and reoperation rates, were analyzed. Results: Patients with severely depressed RV function had significantly higher mortality rates (p=0.035). Reoperation rates also increased as RV function worsened (p=0.006). No significant difference was found between groups regarding valve size (p>0.05) or the type of surgery (sternotomy or thoracotomy) (p=0.714). Conclusion: Right ventricular dysfunction significantly increases postoperative mortality and reoperation rates in patients undergoing tricuspid valve surgery. Careful preoperative evaluation of RV function, including valve size, is critical for improving surgical outcomes.