Kyungyeon Lee

Kyungyeon Lee

Auto-generated profile, based on publicly available information

Kyungyeon Lee

Department of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
KLKyungyeon Lee
Kyungyeon Lee
TYTaehee Yoon
Taehee Yoon
HYHee-Seon Yang
Hee-Seon Yang
SCSunyeong Cha
Sunyeong Cha
YCYong-Pil Cheon
Yong-Pil Cheon
Hyo-Il JungHyo-Il Jung
Hyo-Il Jung
Medical disorders caused by second-hand smoke are a major public health concern worldwide. To estimate the level of second-hand smoke exposure, salivary diagnostics for cotinine analysis is a compelling alternative in conventional diagnostics using bio-fluids, such as blood and urine, owing to its simple and non-invasive collection method. However, there are several critical issues, such as tedious multisteps, demand for expertise, and field unavailability to collect and transport the purified saliva for further analysis. Here, an all-in-one platform is presented to simply collect real human saliva and directly deliver it onto the biosensing surface. The platform consists of a commercial cotton-swab-type collector, 3D-printed housing, and microfluidic channel integrated with an electrochemical competitive immunosensor to evaluate the level of salivary cotinine. The immunosensor is based on a competitive binding assay between cotinine-conjugated horseradish peroxidase (C-HRP) and cotinine for anti-cotinine binding sites. The current responses obtained from the HRP–thionine–H2O2 system decreased proportionally to the cotinine concentration. This immunosensor successfully detected its target over a range of 1 × 10−1 to 1 × 104 pg ml−1 with a low limit of detection of 6 × 10−2 pg ml−1 and a limit of quantification of 1 × 10−1 pg ml−1. In addition, the platform is applicable to various commercial cotton-swab-type saliva collectors and can successfully transfer the saliva in wide flow rates ranging from 0.1 to 30 ml min−1 without leakage or damage to the sensing surface. Furthermore, the practicality of the proposed platform was evaluated by measuring cotinine in real human saliva from eight non-smokers. The concentration of cotinine was from 45.7 to 890.8 pg ml−1, which was in good agreement with that measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The introduced all-in-one platform represented a reliable performance delivering simple and practical steps in salivary diagnostics.

13 February 2018 in The Analyst
Verified
Journal Article
Closed access
PDF file
JSJoonchul Shin
Joonchul Shin
SCSudesna Chakravarty
Sudesna Chakravarty
WCWooseok Choi
Wooseok Choi
KLKyungyeon Lee
Kyungyeon Lee
DHDongsik Han
Dongsik Han
Hyo-Il JungHyo-Il Jung
Hyo-Il Jung
The emergence of a wide range of applications of smartphones along with advances in ‘liquid biopsy’ has significantly propelled medical research particularly in the field of in vitro diagnostics (IVD). Herein, we have presented a detailed analysis of IVD, its associated critical concerns and probable solutions. It also demonstrates the transition in terms of analytes from minimally invasive (blood) to non-invasive (urine, saliva and sweat) and depicts how the different features of a smartphone can be integrated for specific diagnostic purposes. This review basically highlights recent advances in the applications of smartphone-based biosensors in IVD taking into account the following factors: accuracy and portability; quantitative and qualitative analysis; and centralization and decentralization tests. Furthermore, the critical concerns and future direction of diagnostics based on smartphones are also discussed.