P. Yakum

P. Yakum

Auto-generated profile, based on publicly available information

P. Yakum

Graduate Program in Astronomy, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2025 in The Astrophysical Journal
Verified
Journal Article
Open access
SKS. Khamphakdee
S. Khamphakdee
WNW. Nuntiyakul
W. Nuntiyakul
CBC. Banglieng
C. Banglieng
ASA. Seripienlert
A. Seripienlert
PYP. Yakum
P. Yakum
SKSiramas Komonjinda
Siramas Komonjinda
Neutron monitors are a standard tool for high-precision monitoring of changes in the Galactic cosmic ray (GCR) flux that occur as a result of variations of the heliospheric conditions and solar storms. In Thailand, we have developed a mobile neutron monitor named “Changvan” based on the 3NM64 design, except that the middle counter lacks lead producer rings, so we call it a semileaded neutron monitor. From 2021 April to 2023 April, the Changvan operated at the Science and Technology Park, Mae Hia, Chiang Mai, Thailand, at an altitude of about 340 m above sea level, with a vertical cutoff rigidity of 16.7 GV, which is near the highest value observed globally. With a similar cutoff rigidity, the nearby Princess Sirindhorn Neutron Monitor is an 18NM64 at the summit of Doi Inthanon, the highest mountain in Thailand, at 2560 m above sea level. We examine how count rates at different altitudes with similar cutoffs, count rates from the unleaded versus leaded counters, and the leader fraction measured from time-delay histograms all reflect GCR spectral differences, thus providing a variety of techniques for tracking cosmic-ray spectral changes. Applied at high cutoff rigidity, these methods extend the reach of the worldwide neutron monitor network to even higher rigidity.

1 August 2026 in The Astrophysical Journal Supplement Series
Verified
Journal Article
Open access
PYP. Yakum
P. Yakum
ASA. Seripienlert
A. Seripienlert
WNW. Nuntiyakul
W. Nuntiyakul
PEP. Evenson
P. Evenson
DRD. Ruffolo
D. Ruffolo
SKSiramas Komonjinda
Siramas Komonjinda
Neutron monitors serve as the premier instruments for continuous, precise, real-time count rates of secondary particles from cosmic-ray showers, and recently developed techniques provide measures of the spectral index as well. We investigate the rigidity dependence of two such measures, the leader fraction and the count-rate ratio between leaded and unleaded counters, from the transportable semileaded neutron monitor “Changvan” during 2018–2019 and 2019–2020 latitude surveys on board the Chinese icebreaker Xue Long. Changvan comprises two outer leaded counters and one central counter without a lead producer, allowing simultaneous measurements of leaded and unleaded responses within a common moderator–reflector structure. Because the unleaded counter is embedded in the same assembly, its response is very different from that of an isolated bare detector. We examine the behaviors of the count-rate ratio CLeaded/CUnleaded and leader fractions LLeaded and LUnleaded over a wide range of geomagnetic cutoff rigidity. The count-rate ratio and both leader fractions decrease systematically with increasing cutoff rigidity, and Monte Carlo calculations reproduce the observed trends in leader fraction. Comparison with an earlier 2006–2007 fully leaded latitude survey suggests a consistent physical interpretation in which neutrons escaping from the leaded counters contribute to both count-rate and leader-fraction behavior. The unleaded counter acquires enhanced high-rigidity response through neutrons originating from lead around neighboring counters. This study confirms that the count-rate ratio and leader fractions serve to measure spectral variations, and the variations in leader fraction are well modeled by Monte Carlo simulations.