Lok Hin Law

Lok Hin Law

Auto-generated profile, based on publicly available information

Lok Hin Law

Department of Biomedical Engineering City University of Hong Kong Hong Kong China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2023 in Journal of Controlled Release
Verified
Journal Article
Open access
LLLok Hin Law
Lok Hin Law
JHJianpan Huang
Jianpan Huang
PXPeng Xiao
Peng Xiao
YLYang Liu
Yang Liu
ZCZilin Chen
Zilin Chen
Kannie WY ChanKannie WY Chan
Kannie WY Chan
Image guided nose-to-brain drug delivery provides a non-invasive way to monitor drug delivered to the brain, and the intranasal administration could increase effective dose via bypassing Blood Brain Barrier (BBB). Here, we investigated the imaging of liposome-based drug delivery to the brain via intranasal administration, in which the liposome could penetrate mucus and could be detected by chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) at 3T field strength. Liposomes were loaded with a computed tomography (CT) contrast agent, iohexol (Ioh-Lipo), which has specific amide protons exchanging at 4.3 ppm of Z-spectrum (or CEST spectrum). Ioh-Lipo generated CEST contrasts of 35.4% at 4.3 ppm, 1.8% at -3.4 ppm and 20.6% at 1.2 ppm in vitro. After intranasal administration, these specific CEST contrasts were observed in both olfactory bulb (OB) and frontal lobe (FL) in the case of 10% polyethylene glycol (PEG) Ioh-Lipo. We observed obvious increases in CEST contrast in OB half an hour after the injection of 10% PEG Ioh-Lipo, with a percentage increase of 62.0% at 4.3 ppm, 10.9% at -3.4 ppm and 25.7% at 1.2 ppm. Interestingly, the CEST map at 4.3 ppm was distinctive from that at -3.4 pm and 1.2 ppm. The highest contrast of 4.3 ppm was at the external plexiform layer (EPL) and the region between left and right OB (LROB), while the CEST contrast at -3.4 ppm had no significant difference among all investigated regions with slightly higher signal in olfactory limbus (OL, between OB and FL) and FL, as validated with histology. While no substantial increase of CEST contrast at 4.3 ppm, -3.4 ppm or 1.2 ppm was observed in OB and FL when 1% PEG Ioh-Lipo was administered. We demonstrated for the first time the feasibility of non-invasively detecting the nose-to-brain delivery of liposomes using CEST MRI. This multiple-contrast approach is necessary to image the specific distribution of iohexol and liposome simultaneously and independently, especially when designing drug carriers for nose-to-brain drug delivery.

29 August 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
YLYang Liu
Yang Liu
SPSe Weon Park
Se Weon Park
LLLok Hin Law
Lok Hin Law
KWKexin Wang
Kexin Wang
LJLicheng Ju
Licheng Ju
JHJianpan Huang
Jianpan Huang
Purpose: EPI is a fast acquisition sequence, but suffers from geometric distortion because of B 0 field inhomogeneity. This study aims to evaluate the effectiveness of using ΔB 0 map generated from single‐shot CEST‐EPI to achieve distortion self‐correction (DISC). Methods: CEST MRI usually requires B 0 correction during postprocessing, and the ΔB 0 map can be calculated directly from Z‐spectra without extra scan. We propose to use the ΔB 0 map to correct the geometry distortion induced by B 0 field inhomogeneity in CEST‐EPI. The effectiveness of DISC strategy for CEST‐EPI was evaluated on a creatine phantom, healthy and tumor mice at 3 T, and AQP4 heterozygotes mice at 11.7 T. For both the original CEST images and the generated CEST contrast maps, the spatial improvement was first confirmed by the visual comparison and then quantitatively assessed by the structural similarity index measure (SSIM) comparison together with correlation analysis. Results: DISC‐CEST‐EPI showed higher SSIM and spatial consistency compared to CEST‐EPI when using CEST‐rapid acquisition with relaxation enhancement as a reference in vitro and in vivo at 3 T. For in vivo experiments at 11.7 T, SSIM values of amide proton transfer and relayed nuclear Overhauser effects maps of DISC‐CEST‐EPI were slightly higher than CEST‐EPI and comparable with field‐mapping and top‐up. Conclusion: DISC‐CEST‐EPI can correct the distortion in CEST‐EPI at 3 T, leading to improved SSIM and CEST quantification. This approach has the potential to enhance image quality and improve diagnostic accuracy for single‐shot CEST‐EPI at especially low‐field MRI. However, the performance of DISC‐CEST‐EPI is limited at 11.7 T, and further advancements are necessary to enhance its functionality at ultra‐high fields.