Timothée Derkenne

Timothée Derkenne

Auto-generated profile, based on publicly available information

Timothée Derkenne

MIE – Chemistry, Biology and Innovation (CBI) UMR8231, ESPCI Paris, CNRS, PSL Research University, 10 rue Vauquelin, Paris, France

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2024 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MSMatthieu Sagot
Matthieu Sagot
TDTimothée Derkenne
Timothée Derkenne
PGPerrine Giunchi
Perrine Giunchi
YDYohan Davit
Yohan Davit
JNJean-Philippe Nougayrède
Jean-Philippe Nougayrède
BVBastien Venzac
Bastien Venzac
Novel protocol for integration of object inside stereolithography-based chips and proof-of-concepts: bacteria imaging, blue energy and in-flow cell capture.

16 July 2024 in ACS Applied Energy Materials
Verified
Journal Article
Open access
TDTimothée Derkenne
Timothée Derkenne
ACAnnie Colin
Annie Colin
CTCorentin Tregouet
Corentin Tregouet

26 August 2025 in Sustainable Energy & Fuels
Verified
Journal Article
Closed access
PDF file
NWNan Wu
Nan Wu
MFMathieu B. A. Freville
Mathieu B. A. Freville
ZMZhiyi Man
Zhiyi Man
ACAdérito Fins Carreira
Adérito Fins Carreira
TDTimothée Derkenne
Timothée Derkenne
ACAnnie Colin
Annie Colin
We challenge the claim that the experimental process reported in the article shows it is possible to set up a reverse electrodialysis cell capable of achieving power values of 5 W m−2.

16 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
TDTimothée Derkenne
Timothée Derkenne
ACAnnie Colin
Annie Colin
CTCorentin Tregouet
Corentin Tregouet
Open-circuit conditions impose zero net external current, but do not necessarily imply the absence of local ionic currents. Here, we identify a spatially distributed mechanism by which such currents spontaneously organize into closed loops. In a millifluidic cell fed by two KCl streams of different salinities, non-ideal ion-exchange membranes allow neutral salt transport that progressively relaxes the salinity gradient along the flow direction. This longitudinal relaxation generates spatial variations in the local membrane and electrode equilibrium potentials. Because the conducting electrodes remain equipotential, these local electromotive forces cannot equilibrate independently and instead drive hidden current loops through the coupled membrane, electrolyte and electrode system. Using segmented Ag/AgCl electrodes, we directly detect these loops through opposite redox patterns and local currents reaching hundreds of nanoamperes. A Nernst-Planck model coupling channel advection, membrane electrodiffusion and electrode boundary conditions quantitatively reproduces the velocity-dependent open-circuit voltage and predicts the spatial inversion of the local current. Remarkably, the local membrane current can be predominantly carried by chloride ions despite the cation-selective character of the membrane. These results show that a vanishing macroscopic current can conceal sustained and spatially organized local ionic currents, with direct consequences for the interpretation of membrane selectivity measurements.

3 November 2023 in Research Square
Verified
Preprint
Open access
PDF file
CTCorentin Tregouet
Corentin Tregouet
ACAnnie Colin
Annie Colin
TDTimothee Derkenne
Timothee Derkenne
Blue energy represents a large reservoir of renewable osmotic energy that can be converted into electricity by reverse electrodialysis (RED). This method is based on ion-exchange membrane. Before large scale production, these membranes are compared on very small samples on the basis of the power they enable to produce per unit area. Through a systematic study of the effect of the membrane size on the power density, we show experimentally that for classical measurement cells, the power density strongly varies with the size of the membrane: the smaller the membrane, the higher the power density. The results are explained by a theoretical modeling which describes the effect of the access resistance at the scale of the membrane. Based on this work, a few recommendations are formulated to perform scalable and meaningful measurements of membrane resistance and power density.

22 November 2024 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
TDTimothée Derkenne
Timothée Derkenne
ACAnnie Colin
Annie Colin
CTCorentin Tregouet
Corentin Tregouet
Ion exchange membranes (IEMs) are widely used in industrial sectors from batteries and energy harvesting, to water treatment and desalination. They are designed with a high selectivity and a low electrical resistance. However, the way to measure such performances independently from interpretation and device parameters (geometrical sizes, water flux, electrodes, measurement type, etc.) remains a challenge. Therefore, many performances announced in the current literature are not reliable. This study focuses on membranes prepared for reverse electro-dialysis applications, but could be generalized to other membrane based processes. Due to the rising energy demand and the severe environmental crisis, worldwide reduction of conventional fossil fuel consummation is needed. As a renewable and clean energy resource, the Blue energy is an osmotic energy released during the mixing of solutions of different salinity. Naturally, an irreversible mixing of river water and sea water happens at the estuary. A precise and engineering control of this mixing enables the blue energy harvesting. The worldwide salinity gradient energy could reach 70 GW, which is not negligeable. Since the beginning of blue-energy harvesting research, a lot of advances have been made about membrane design and nanofluidic diffusio-osmotic transport, but the efficiency gap of 6 orders of magnitude between nano-scale designs and industrial power plants remains unsolved. Just after synthesis, selective membranes are benchmarked on very small samples on the basis of the output power. It is usually calculated based on the membrane resistance per unit area, and the measured Donnan potential. This method of power per unit area based on membrane resistance is therefore a key point to compare several devices and their efficiency. A classical electrochemical cell has been used to place a Nafion selective membrane of varying area between two electrodes. The membrane resistance and power density have been experimentally measured. Homogeneous salt concentration or gradient of concentration have been used to measure different parameters. This systematic study shows that for classical measurement cells, the membrane resistance is inversely proportional to the square root of its area. Whereas it's currently assumed in the literature that the resistance and the area of a membrane are inversely proportional. Based on this assumption, the power density is believed to be independent of the membrane area (reason why it is used as a comparison criteria), which we prove to be wrong. This result has a big impact on the reliability of the power density announced in the literature for different devices: the smaller the area of the tested membrane the higher is the output power density: from 0,5 W/m² up to 150 W/m² for the same membrane, same salt ratio (100) different membrane areas. This leads to overly optimistic extrapolation of electrical performances for membranes engineered and tested at sub millimeter sizes that will be industrially used at meter sizes. To explain these results, we show that for small membranes (compared to the electrode size and distance) there is an access resistance at the scale of the membrane. It results that the area mismatch between the membrane and the electrodes add a new resistance in the system that does not scale with the membrane area and that is taken into account in membrane characterizations. Experimental data and theoretical modeling are corroborating without any adjustment parameters. Consequently, the power per unit area obtained at micro scale cannot be extrapolated a priori to larger membranes. So, the comparison is biased between large scale commercially available membranes, and nano-engineered microscale membranes. This raises the urgent need for new indicators or standard measurement protocols. Based on these conclusions, we formulate a few recommendations to perform scalable and meaningful measurements of membrane resistance and power density.