Benjamin Googe

Benjamin Googe

Auto-generated profile, based on publicly available information

Benjamin Googe

Univ Mississippi, Med Ctr, Div Plast Surg, 2500 N State St, Jackson, MS 39216 USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in American Journal of Otolaryngology
Verified
Journal Article
Closed access
BGBenjamin J. Googe
Benjamin J. Googe
JCJeffrey D. Carron
Jeffrey D. Carron

1 May 2016 in American Journal of Otolaryngology
Verified
Journal Article
Closed access
ANAndrew M. Nida
Andrew M. Nida
BGBenjamin J. Googe
Benjamin J. Googe
ALAndrea F. Lewis
Andrea F. Lewis
WMWarren L. May
Warren L. May

9 January 2020 in Annals of Plastic Surgery
Verified
Journal Article
Closed access
BGBenjamin Googe
Benjamin Googe
JDJohn Clayton Bs Davidson
John Clayton Bs Davidson
PAPeter B. Arnold
Peter B. Arnold
AMAbelardo Medina
Abelardo Medina
Closed incisional negative pressure wound therapy (ciNPWT) has become commonplace in surgery. One mechanism ciNPWT may prevent incision site complications is by off-loading tension. This study aimed to find what width sponge using ciNPWT provides the most tension off-loading. A model was designed to test tension off-loading of a wound using ciNPWT. An incision was made in an anatomy model and closed with single stitch at the central axis. Force was applied tangentially using a force gauge at a steady rate until the wound dehisced at a peak force indicated by the 5-0 suture breaking. This was repeated 10 times for the following 4 trials: no ciNPWT and ciNPWT sponges cut a 3-, 6-, and 9-cm widths with 125 mm Hg of negative pressure. The mean peak force to dehisce the wound without ciNPWT was the lowest, 28.7 N. The mean force for the ciNPWT trials was 43.0, 38.7, and 36.4 N for V.A.C. sponges of 3, 6, and 9 cm in width, respectively. There was a statically significant difference among all the trials using one-way analysis of variance with Tukey posttest analysis with a P value of less than 0.0001. Closed incisional negative pressure wound therapy was shown to increase peak force required to dehisce an incision of up to 49.7% compared with closure without. There is an inverse relationship with sponge width and tension off-loading. The smaller the sponge, the more tension is off-loaded across the incision. Closed incisional negative pressure wound therapy with a 3-cm-wide sponge required the greatest peak force for dehiscence.

17 September 2015 in Case Reports in Otolaryngology
Verified
Journal Article
Open access
PDF file
BGBenjamin Googe
Benjamin Googe
ANAndrew Nida
Andrew Nida
JSJohn Schweinfurth
John Schweinfurth
A 77-year-old female with bilateral vocal cord paralysis and dependent tracheostomy status after total thyroidectomy presented to clinic for evaluation of decannulation via arytenoidectomy. Preliminary data suggests coblation versus standard CO2 laser ablation in arytenoidectomy may provide benefits in terms of decreased tissue necrosis and patient outcome. The patient elected to proceed with arytenoidectomy by coblation. The initial procedure went well but postoperative bleeding required a return trip to the operating room for hemostasis. In the coming months the patients tracheostomy tube was gradually downsized and eventually capped. She was decannulated eight months after surgery, speaking well and without complaints. Details of the surgical procedure and outcome will be discussed. A 77-year-old female with bilateral vocal cord paralysis and dependent tracheostomy status after total thyroidectomy presented to clinic for evaluation of decannulation via arytenoidectomy. Preliminary data suggests coblation versus standard CO2 laser ablation in arytenoidectomy may provide benefits in terms of decreased tissue necrosis and patient outcome. The patient elected to proceed with arytenoidectomy by coblation. The initial procedure went well but postoperative bleeding required a return trip to the operating room for hemostasis. In the coming months the patients tracheostomy tube was gradually downsized and eventually capped. She was decannulated eight months after surgery, speaking well and without complaints. Details of the surgical procedure and outcome will be discussed.

13 April 2016 in Otolaryngology Head and Neck Surgery
Verified
Journal Article
Open access
UCUniversity of Mississippi Medical Center
University of Mississippi Medical Center
BGBenjamin Googe
Benjamin Googe
Herald Scholarly Open Access publishes peer-reviewed scientific research which provides an immediate free access to articles. Herald Scholarly Open Access is publishing articles in 47 peer-reviewed Open Access journals in Biology, Medicine and Clinical sciences.

10 July 2019 in Wound Management & Prevention
Verified
Journal Article
Closed access
BGBenjamin Googe
Benjamin Googe
ALAlexandra E. Lackey
Alexandra E. Lackey
PAPeter A. Arnold
Peter A. Arnold
LVLaura R. Vick
Laura R. Vick
Operative positioning of morbidly obese patients presents unique challenges and can cause complications, especially when the operative field involves the proximal lower extremity or genitoperineal region. PURPOSE: The purpose of this case study was to describe a modified lithotomy operative positioning technique that has helped the authors improve care of these patients.METHODS: Double-layer, foam padding at least 4 inches thick is secured to the top and sides of 2 small rolling preparation tables using 3-inch silk tape to create "lithotomy" leg holders, the operating table is raised appropriately, the abducted legs are placed onto the padded prep tables, and the footboard is carefully lowered to provide access to the groin and medial thighs.CASE STUDY: A super morbidly obese (body mass index 74), 47-year-old African American man with a history of hypertension and type 2 diabetes controlled on oral medications presented to the authors' wound care clinic with 2 large, medial left thighlymphedema masses requiring resection. Both procedures were successfully completed using the modified lithotomy position.No adverse events occurred. CONCLUSION: The modified lithotomy is easy to implement, does not require unique equipment,improves access to the surgical site, and may reduce the risk of complications. Larger and longer-term follow-up studies are needed to monitor the outcomes of this positioning technique.