The analysis of the thermal condition of spent FA (fuel assembly) of BN-350 reactor in a six-place cask for dry storage is presented. Simulation of the thermal condition of the cask is conducted with finite elements method using ANSYS software. Calculations of fuel temperature, fuel cladding, and assembly structural elements are the part of the safety analysis for storage of spent FA. In conclusion, the results of the thermal calculations in the cases of filling cask with argon and atmospheric air are given when the thickness of the insulation cask with concrete is 0.5 and 1 m. As a result of the calculated studies, the parameters of SNF (spent nuclear fuel) storage are determined, under which the fuel temperatures will have minimum and maximum values.
This article presents an analysis of thermal state of a fuel element of the WCTC-LEU of the IVG.1M reactor implemented for a case when a fuel matrix is separated from the fuel cladding along a short side of the blade. Technology of a fuel element manufacture for the modernized core considers presence of non-uniformity in microstructure. To evaluate how separations of a typical size affects the thermal mode of fuel element operation, temperature fields in cross-sections of the fuel element have been calculated. Thermophysical calculations were conducted using the finite element method with ANSYS program complex. Based on the variants calculation, it was obtained data on the effect of the separation on temperature field distribution of the fuel element during the IVG.1M reactor running at design and nominal power.