Gabriel Gustinelli Arantes de Carvalho

Gabriel Gustinelli Arantes de Carvalho

Auto-generated profile, based on publicly available information

Gabriel Gustinelli Arantes de Carvalho

Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, 05513-970 São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2018 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
GCGabriel Gustinelli Arantes de Carvalho
Gabriel Gustinelli Arantes de Carvalho
MGMarcelo Braga Bueno Guerra
Marcelo Braga Bueno Guerra
AAAndressa Adame
Andressa Adame
CNCassiana Seimi Nomura
Cassiana Seimi Nomura
POPedro Vitoriano Oliveira
Pedro Vitoriano Oliveira
FKFrancisco José Krug
Francisco José Krug
The ability to provide a fast and multielemental analytical response directly from a solid sample makes both laser-induced breakdown spectroscopy (LIBS) and X-ray fluorescence spectrometry (XRF) very versatile tools for plant nutrition diagnosis. This review focuses on the main developments and advances in LIBS and XRF in the analysis of plant materials over the last ten years. Fundamental aspects and instrumentation are given for both techniques. The developments in the quantitative analysis of plant leaves are discussed, with special emphasis on the key aspects and challenges concerning field sampling protocols, sample preparation, and calibration strategies. Microchemical imaging applications by LIBS and XRF (including synchrotron radiation) are also presented in a broader selection of plant compartments (e.g., leaves, roots, stems, and seeds). Challenges, expectations and complementarities of LIBS and XRF towards plant nutrition diagnosis are thoroughly discussed.

1 December 2018 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
GCGabriel G. Arantes de Carvalho
Gabriel G. Arantes de Carvalho
GKGislayne A.R. Kelmer
Gislayne A.R. Kelmer
PFPedro Fardim
Pedro Fardim
POPedro Vitoriano Oliveira
Pedro Vitoriano Oliveira
Denise Freitas Siqueira PetriDenise Freitas Siqueira Petri
Denise Freitas Siqueira Petri

1 December 2016 in Talanta
Verified
Journal Article
Closed access
GCGabriel G. Arantes de Carvalho
Gabriel G. Arantes de Carvalho
SKStalin Kondaveeti
Stalin Kondaveeti
Denise Freitas Siqueira PetriDenise Freitas Siqueira Petri
Denise Freitas Siqueira Petri
AFAlexandre M. Fioroto
Alexandre M. Fioroto
LALuiza G.R. Albuquerque
Luiza G.R. Albuquerque
POPedro V. Oliveira
Pedro V. Oliveira

8 August 2018 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
GCGabriel G. Arantes de Carvalho
Gabriel G. Arantes de Carvalho
Denise Freitas Siqueira PetriDenise Freitas Siqueira Petri
Denise Freitas Siqueira Petri
POPedro Vitoriano Oliveira
Pedro Vitoriano Oliveira
This work presents a method for the single-stage preconcentration and simultaneous determination of 14 rare earth elements (REEs), La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu, in fresh waters using calcium alginate (CA) microparticles as a substrate for further determination by single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). On-line analyte preconcentration was achieved using a flow-injection system incorporating a column filled with CA microparticles (<180 μm size; 300 mg). The proposed procedure was validated for 100 mL test portions, providing an enrichment factor of 100. The method was applied for the analysis of tap water and river water test samples, and validation was carried out with the analysis of the corresponding test samples spiked with 10 μg kg−1 REEs standard solution (La–Lu), wherein recoveries ranging from 90 to 102% were obtained. Coefficients of variation of REEs determinations were smaller than 4.0% (inter-column reproducibility, n = 3). The limit of detection of the method ranged from 0.01 to 0.03 ng kg−1 (achieved with a 100-fold pre-concentration). The procedure (sample loading, rinsing and elution) takes ca. 30 min per replicate. The proposed approach using CA columns is a reliable and low cost alternative for single-stage REEs preconcentration prior to ICP-MS measurements, and can be recommended for the analysis of river water and tap water samples. CA column re-usability was confirmed up to 50 adsorption–desorption cycles.

21 May 2020 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
RLRodolfo Lorençatto
Rodolfo Lorençatto
GCGabriel Gustinelli Arantes de Carvalho
Gabriel Gustinelli Arantes de Carvalho
POPedro Vitoriano Oliveira
Pedro Vitoriano Oliveira
In this work a method for the direct analysis of liquid drug samples by inductively coupled plasma mass spectrometry (ICP-MS) with aerosol dilution was proposed. Multivariate studies were executed for optimization of ICP-MS parameters (sample depth, aerosol dilution gas flow rate and He gas flow rate) using a representative diluted drug sample aiming at appropriate plasma robustness parameters (140Ce2+/140Ce+ and 140Ce16O+/140Ce+ ratios), as well as sensitivity for Ag, As, Au, Ba, Cd, Co, Cr, Cu, Hg, Ir, Li, Mo, Ni, Os, Pb, Pd, Pt, Rh, Ru, Sb, Se, Sn, Tl and V, the elemental impurities in USP Chapter 232. The results showed that the dilution gas had a major role in formation of doubly charged and oxide ions. A robust plasma condition was achieved (i.e., 140Ce2+/140Ce+ < 0.9% and 140Ce16O+/140Ce+ < 0.3%) when 0.40 L min−1 dilution gas flow rate was used. The combination of collision (He) gas and dilution gas flow rates was the key feature for minimizing (or even removing) polyatomic interferences. It was verified that collision cell processes benefit from less sample matrix introduction provided by aerosol dilution. Method validation has been accomplished and reported for a liquid drug for hepatic disorders. The results successfully met the requirements of the USP Chapter 233 procedure, wherein appropriate figures of merit were obtained (R > 0.995 and RSD < 6.2% for precision tests, RSD < 14% for intermediate precision tests, and 88–125% recoveries for a 50-fold diluted spiked sample with different J concentrations). This study provided useful information about the benefits of aerosol dilution and demonstrates that ICP-MS with aerosol dilution is a reliable method for the direct analysis of liquid drug samples in order to meet the requirements of USP Chapters 232 and 233.

20 December 2023 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
AVAlan Lima Vieira
Alan Lima Vieira
GCGabriel Gustinelli Arantes de Carvalho
Gabriel Gustinelli Arantes de Carvalho
JNJosé Anchieta Gomes Neto
José Anchieta Gomes Neto
POPedro Vitoriano Oliveira
Pedro Vitoriano Oliveira
MKMarcos Yassuo Kamogawa
Marcos Yassuo Kamogawa
AVAlex Virgilio
Alex Virgilio
This work presents a new, robust, and reliable conductively heated digestion system with closed vessels (CHDS) for the preparation of plant materials for elemental determination by inductively coupled plasma optical emission spectrometry (ICP OES). The proposed system combines the simplicity of a 24-slot resistively heated aluminum block with the key advantages inherent to closed vessels. Fundamental studies on temperature and pressure were also performed and the difference between the liquid phase temperature (190 °C) and the aluminum block temperature (240 °C) was assigned to the dynamic condensation of the gaseous phase during digestion. The optimized digestion procedure was achieved for 250 mg test portions, 2.0 mL of HNO3 (65% v v−1), 1.5 mL of H2O2 (30% v v−1), and a temperature of 240 °C, with a heating rate of 10 °C min−1 and dwell time of 20 min. Under these conditions, the residual carbon contents in digests were generally below 700 mg L−1. The performance of the CHDS was checked by analyzing plant certified reference materials and the determined concentrations of B, Ca, Cu, Fe, K, Mg, Mn, P, S, and Zn presented no significant differences when compared to the certified values at the 95% confidence level. Recoveries in the 75–108% range and relative standard deviations ≤3% (n = 3) were typically obtained. Also, the system was applied to the analysis of sixteen samples from an interlaboratory trial, and a comparison with alternative single reaction chamber microwave-assisted digestion (SRC MWAD) and open vessel nitro-perchloric decomposition (NP) digestion methods also showed equivalence at a 95% confidence level in most cases. The CHDS system based on thermally convective heating allowed digestion of up to 24 different plant materials in ca. 50 min, but it is not limited to samples and analytes chosen in this work: the CHDS is designed for typical use in elemental inorganic analysis techniques that require liquid-based sample introduction.