Zhuyi Ma

Zhuyi Ma

Auto-generated profile, based on publicly available information

Zhuyi Ma

Department of Adult Joint Reconstruction, Beijing Jishuitan Hospital, Capital Medical University, Fourth Clinical College of Peking University, Beijing, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2021 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
HTHao Md Tang
Hao Md Tang
YLYa Masc Li
Ya Masc Li
YZYinxin Zhou
Yinxin Zhou
SWSiyuang Wang
Siyuang Wang
YZYongqiang Zhao
Yongqiang Zhao
ZMZhuyi Ma
Zhuyi Ma
Background: Lumbar-pelvic stiffness and sagittal imbalance have been reported to increase the risk of dislocation and wear after THA. One potential way to approach this concern is by identifying patient-specific safe zones for THA components based on the standing and sitting sagittal pelvic tilt. However, there is no algorithm to integrate the standing and sitting pelvic tilt into the surgical plan of component orientations. Questions/purposes: We established a new mathematical algorithm for determining a patient-specific safe zone for THA by integrating the impingement-free ROM requirements of standing and sitting while preventing edge loading while standing. We aimed to determine (1) the accuracy of this new method for predicting the impingement-free ROM for a given component orientation, (2) the sensitivity and specificity of detecting an impingement-free acetabular cup position for standing and sitting, and (3) the influences of key factors including pelvic tilt while standing and pelvic tilt while sitting and implant parameters on patient-specific safe zones. Methods: A strategy for calculating the intersection of standing and sitting impingement-free safe zones and the zone of a standing radiographic inclination of ≤ 45° was used to develop patient-specific safe zones. We conducted a computer simulation study including the pelvis and THA prosthesis to answer the three study questions. We enrolled 10 patients who underwent robot-assisted THA for avascular necrosis of the femoral head (mean age 49 ± 19 years; five were women) from October 2019 to December 2019. We used a prosthesis model with a conical stem neck and a non-hooded liner, with the femoral head diameter ranging between 28 mm and 40 mm, and the corresponding head-neck ratio ranging between 2.33 and 3.33. We tested 1680 movements for the accuracy of impingement-free ROM (Question 1), and 80 marginal points and 120 non-marginal points of the comprehensive impingement-free safe zone, which combines the standing and sitting postures (Question 2). For Question 3, we explored the influences of standing and sitting pelvic tilt, femoral head diameter, and ROM criteria on the size of the patient-specific safe zone. Results: With the simulation method as a reference for detecting impingement, the mean absolute error (arithmetic mean of all the absolute errors) of the calculated impingement-free ROM was 1.4° ± 2.3°, and the limit of agreement of errors was between -3.6° and 3.7°. The sensitivity of detecting a safe cup orientation within the comprehensive impingement-free safe zone for a given ROM criterion was 98.9% (95% CI 93.6% to 99.9%), and specificity was 97.1% (95% CI 91.0% to 99.2%). There were no impingement-free safe zones for 29% (pelvic tilt combinations without an impingement-free safe zone and all tested combinations) and no patient-specific safe zones for 46% (pelvic tilt combinations without a patient-specific safe zone and all tested combinations) of the tested combinations of standing and sitting pelvic tilt. The patient-specific safe zone was sensitive to changes in standing and sitting pelvic tilt, femoral head diameter, stem version, and ROM criteria. Stem anteversions beyond 10° to 20° dramatically reduced the size of the patient-specific safe zone to 0 within a change of 10° to 20°. Conclusion: The patient-specific safe zone algorithm can be an accurate method for determining the optimal orientation for acetabular cups and femoral stems in THA. The patient-specific safe zone is sensitive to changes in standing and sitting pelvic tilt, stem version, ROM criteria, and the femoral head diameter. A narrow zone of 10° to 20° for stem anteversion is recommended to maximize the size of the patient-specific safe zone. Clinical Relevance: This study suggests the potential of a mathematical algorithm to optimize the orientation of THA components and illustrates how key parameters affect the patient-specific safe zone.

9 February 2022 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
HTHao Tang
Hao Tang
YZYongqiang Zhao
Yongqiang Zhao
SWSiyuan Wang
Siyuan Wang
ZMZhuyi Ma
Zhuyi Ma
YLYa Li
Ya Li
YZYinxin Zhou
Yinxin Zhou
Background: Ante-inclination (AI) of the cup is a key component of the combined sagittal index (CSI) for predicting joint stability after total hip arthroplasty (THA). We aimed to (1) validate a mathematical algorithm relating AI to radiographic anteversion (RA), radiographic inclination (RI), and pelvic tilt (PT); (2) convert the AI criterion of the CSI into the coronal functional safe zone (CFSZ) and explore the influences of standing-to-sitting pelvic motion (PM) and pelvic incidence (PI) on the CFSZ; and (3) attempt to locate a universal cup orientation that always fulfills the AI criterion of the CSI for all patients. Methods: In the first phase, a phantom pelvis was designed to simulate a range of PT values, and an acetabular cup was implanted with different RA, RI, and PT settings using a robot-assisted technique and scanned using the EOS imaging system. The second phase involved patient radiographs. We enrolled 100 patients who underwent robot-assisted THA from April 2019 to December 2019, and EOS images before THA and at the 12-month follow-up were recorded. The AI was measured on a lateral radiograph; this angle was used as the reference and compared with the calculated AI to assess the accuracy of the algorithm. Linear regression was conducted to explore the relationship between the size of the CFSZ and the values of PM and PI. We calculated the intersection of the CFSZs of the patients to find a universal cup orientation (RA and RI) for the CSI. Results: The algorithm was accurate according to both the phantom study and patient radiographs using PT at the time of follow-up, with mean absolute errors (MAEs) of 1.5° (width of 95% confidence interval [CI], 2.2°) and 2.8° (width of 95% CI, 3.0°), respectively. However, the preoperatively predicted AI had an MAE of 9.0° (width of 95% CI, 10.5°). In patient subgroups with lower PM or PI, the sizes of the CFSZ and of its intersection with the Lewinnek safe zone were significantly smaller (p < 0.017). No universal cup orientation existed to fulfill the CSI criteria for all patients or for any of the PM or PI subgroups. Conclusions: The target orientation for the cup in THA should be individualized. Our validated algorithm may serve as a quantitative tool for the patient-specific optimization of cup AI on the basis of the functional safe zone. Clinical Relevance: The Lewinnek safe zone fails because it cannot predict the functional orientation of the cup. The concept of a universal safe zone of cup orientation should be abandoned and replaced by a patient-specific surgical target.

1 January 2024 in The Bone & Joint Journal
Verified
Journal Article
Open access
PDF file
HTHao Tang
Hao Tang
SGShaoyi Guo
Shaoyi Guo
ZMZhuyi Ma
Zhuyi Ma
SWSiyuan Wang
Siyuan Wang
YZYinxin Zhou
Yinxin Zhou
Aims: The aim of this study was to evaluate the reliability and validity of a patient-specific algorithm which we developed for predicting changes in sagittal pelvic tilt after total hip arthroplasty (THA).Methods: This retrospective study included 143 patients who underwent 171 THAs between April 2019 and October 2020 and had full-body lateral radiographs preoperatively and at one year postoperatively. We measured the pelvic incidence (PI), the sagittal vertical axis (SVA), pelvic tilt, sacral slope (SS), lumbar lordosis (LL), and thoracic kyphosis to classify patients into types A, B1, B2, B3, and C. The change of pelvic tilt was predicted according to the normal range of SVA (0 mm to 50 mm) for types A, B1, B2, and B3, and based on the absolute value of one-third of the PI-LL mismatch for type C patients. The reliability of the classification of the patients and the prediction of the change of pelvic tilt were assessed using kappa values and intraclass correlation coefficients (ICCs), respectively. Validity was assessed using the overall mean error and mean absolute error (MAE) for the prediction of the change of pelvic tilt.Results: The kappa values were 0.927 (95% confidence interval (CI) 0.861 to 0.992) and 0.945 (95% CI 0.903 to 0.988) for the inter- and intraobserver reliabilities, respectively, and the ICCs ranged from 0.919 to 0.997. The overall mean error and MAE for the prediction of the change of pelvic tilt were -0.3° (SD 3.6°) and 2.8° (SD 2.4°), respectively. The overall absolute change of pelvic tilt was 5.0° (SD 4.1°). Pre- and postoperative values and changes in pelvic tilt, SVA, SS, and LL varied significantly among the five types of patient.Conclusion: We found that the proposed algorithm was reliable and valid for predicting the standing pelvic tilt after THA.Cite this article: Bone Joint J 2024;106-B(1):19–27.

17 August 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
SMSiliang Man
Siliang Man
LZLiang Zhang
Liang Zhang
TBTao Bian
Tao Bian
HLHongchao Li
Hongchao Li
ZMZhuyi Ma
Zhuyi Ma
YZYinxin Zhou
Yinxin Zhou
Background: This study aimed to test the reliability and validity of the Hip Inflammation MRI Scoring System (HIMRISS) in assessing hip involvement of AS patients with AS at different stages of the bath ankylosing spondylitis radiology index (BASRI-hip) scoring system. Methods: Fifty-two outpatients with ankylosing spondylitis (AS) were included in this study. The subjects’ data includes demographics, clinical characteristics, disease activity score, and functional index. Based on the Harris hip scoring (HHS) of involved hip and BASRI-hip score, we devided these patients into no hip involvement group((HHS ≥ 80 and BASRI ≤ 1) (Group A), mild hip involvement subgroup (BASRI = 2 or BASRI ≤ 1 and HHS ≤ 79) (Group B), and moderate to advanced hip involvement subgroup (BASRI ≥ 3) (Group C). Data was analyzed statistically by SPSS software. Results: In total of 44 patients (88 hips), group A consisted of 21 hips, group B consisted of 42 hips and group C consisted of 25 hips. The test–retest intraclass correlation coefficients (ICCs) in four raters were 0.955 ~ 0.977 and interrater ICC was 0.993. HIMRISS correlated moderately with the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) (r = 0.540, p < 0.001), the Bath ankylosing spondylitis functional index (BASFI) (r = 0.540, p < 0.001), the Bath Ankylosing Spondylitis Functional Index (BASFI) (r = 0.581, p < 0.001), ASDAS-ESR (r = 0.604, p < 0.001), and Ankylosing Spondylitis Disease Activity Score (ASDAS)-C reactive protein (CRP) (r = 0.575, p < 0.001). HIMRISS in groups B and C was significantly higher than that in group A: 29.38 (17.00, 40.94) vs. 14.50 (11.38, 22.25), p = 0.009; 38 (31.13, 64.38) vs 14.50 (11.38, 22.25), p < 0.001. Conclusions: HIMRISS applied to patients with AS demonstrated a satisfactory reliability, meaning it is a reliable quantitive assessment tool for evaluating early hip involvement in patients with AS.

26 September 2022 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
ZMZhuyi Ma
Zhuyi Ma
HTHao Tang
Hao Tang
YZYinxin Zhou
Yinxin Zhou
SWSiyuan Wang
Siyuan Wang
DYDejin Yang
Dejin Yang
SGShaoyi Guo
Shaoyi Guo
Background: Three-dimensional computed tomography (3D CT) reconstruction is the reference standard for measuring component orientation. However, functional cup orientation in standing position is preferable compared with supine position. The low-dose bi-planar radiographs can be used to analyze standing cup component orientation. We aimed to assess the validity and reliability of the component orientation using the low-dose bi-planar radiographs compared with the 3D CT reconstruction, and explore the differences between the functional cup orientation in standing radiographs and supine CT scans.Methods: A retrospective study, including 44 patients (50 hips) with total hip arthroplasty (THA), was conducted. CT scans were taken 1 week after surgery and the low-dose bi-planar radiographs were taken in the follow-up 6 weeks later. Component orientation measurement was performed using the anterior pelvic plane and the radiographic coronal plane as reference, respectively.Results: The study showed no significant difference in cup anteversion (p = 0.160), cup inclination (p = 0.486), and stem anteversion (p = 0.219) measured by the low-dose bi-planar radiographs and 3D reconstruction. The differences calculated by the Bland–Altman analysis ranged from − 0.4° to 0.6° for the three measured angles. However, the mean absolute error was 4.76 ± 1.07° for functional anteversion (p = 0.035) and 4.02 ± 1.08° for functional inclination (p = 0.030) measured by the bi-planar radiographs and supine CT scans.Conclusions: The low-dose bi-planar radiographs are the same reliable and accurate as 3D CT reconstruction to assess post-THA patients’ component orientation, while providing more valuable functional component orientation than supine CT scans.