Yuhang Liu

Yuhang Liu

Auto-generated profile, based on publicly available information

Yuhang Liu

LIST, Key Laboratory of New Generation Artificial Intelligence Technology and Its Interdisciplinary Applications, Ministry of Education, and Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing, Southeast University, Nanjing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2023 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Closed access
RYRongbiao Yan
Rongbiao Yan
YLYi Liu
Yi Liu
YLYuhang Liu
Yuhang Liu
LWLei Wang
Lei Wang
RZRongge Zhao
Rongge Zhao
ZGZhiguo Gui
Zhiguo Gui
Removing noise and artifacts from low-dose computed tomography (LDCT) is a challenging task, and most existing image-based algorithms tend to blur the results. To improve the resolution of denoising results, we combine convolutional dictionary learning and convolutional neural network (CNN), and propose a transfer learning densely connected convolutional dictionary learning (TLD-CDL) framework. In detail, we first introduce the dense connections and multi-scale Inception structure to the network, and train the pre-model on the natural image dataset, then fit the model to the post-processing of LDCT images in the way of transfer learning. In addition, considering that a single pixel-level loss is difficult to achieve satisfactory results both in the index and visual perception, we use the compound loss function of L1 loss and SSIM loss to guide the training. The experimental result shows that TLD-CDL has a good balance between noise reduction and the preservation of details, and acquires inspiring effectiveness in terms of qualitative and quantitative perspective.

10 October 2022 in NDT & E International
Verified
Journal Article
Closed access
YLYuhang Liu
Yuhang Liu
YLYi Liu
Yi Liu
PZPengcheng Zhang
Pengcheng Zhang
RYRongbiao Yan
Rongbiao Yan
LWLei Wang
Lei Wang
ZGZhiguo Gui
Zhiguo Gui

16 February 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
ZGZhiguo Gui
Zhiguo Gui
YLYuhang Liu
Yuhang Liu
YLYi Liu
Yi Liu
WLWenting Liu
Wenting Liu
RYRongbiao Yan
Rongbiao Yan
HSHuazhong Shu
Huazhong Shu
The 3D sparse-view computed laminography (CL) is an important research issue due to its considerable potential in lowering costs. To solve the artifacts and noise caused by sparse-view scanning, the total variation (TV) method is widely used. However, TV only utilizes the prior information of the reconstructed image itself. Therefore, the Prior-image-based reconstruction method (PIBR) is proposed to reduce the artifacts by using a prior image. In this study, we proposed a 3D CL method based on the final prior image and TV for sparse-view scanning, which is divided into two sub-problems corresponding to two solution steps: the novel PIBR step and the denoising step. In the first step, we devise the final prior image and its corresponding prior mask to ensure the effectiveness of the PIBR. The final prior image is obtained based on the prior images, which are reconstructed from two different oblique angle projections. The prior mask is a binary mask, which is used to record the position of the prior image information. Then the denoising step is based on the TV minimization method using the Split-Bregman (SB) frame. Soft shrinkage operations and Fast Fourier Transform (FFT) are used to efficiently implement the SB frame. Compared with several iterative reconstruction methods, the experimental results demonstrate the effectiveness of the proposed method in terms of preserving edges, suppressing inter-slices aliasing and denoising.

5 May 2022 in IEEE Access
Verified
Journal Article
Open access
LWLei Wang
Lei Wang
YLYi Liu
Yi Liu
RWRui Wu
Rui Wu
YLYuhang Liu
Yuhang Liu
RYRongbiao Yan
Rongbiao Yan
ZGZhiguo Gui
Zhiguo Gui
Low-dose CT images contain severe mottle noise and streak artifacts, which seriously affect the physician’s diagnosis of the disease. Hence, in this paper, we propose a novel anisotropic fourth-order diffusion model for low-dose CT image processing. The proposed diffusion model uses both image gradient magnitude and weighted residual local energy to determine the diffusion coefficient. Gradient magnitude is used to detect the image edges, while the weighted residual local energy preserves textures and details in the image. In addition, the fidelity term is introduced into the diffusion model to avoid excessive smoothing and weaken the blocky effects. Experimental results show that when compared with the anisotropic fourth-order diffusion model, the proposed algorithm protects the texture details and suppresses the blocky effects. In comparison with other state-of-the-art algorithms, the proposed model effectively suppresses mottle noise and streak artifacts while simultaneously improving the low-dose CT image quality.

3 April 2022 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PDF file
YLYuhang Liu
Yuhang Liu
YLYi Liu
Yi Liu
PZPengcheng Zhang
Pengcheng Zhang
QZQuan Zhang
Quan Zhang
LWLei Wang
Lei Wang
ZGZhiguo Gui
Zhiguo Gui
The objective of this study is to apply an improved Faster-RCNN model in order to solve the problems of low detection accuracy and slow detection speed in spark plug defect detection. In detail, an attention module based symmetrical convolutional network (ASCN) is designed as the backbone to extract multi-scale features. Then, a multi-scale region generation network (MRPN), in which InceptionV2 is used to achieve sliding windows of different scales instead of a single sliding window, is proposed and tested. Additionally, a dataset of X-ray spark plug images is established, which contains 1,402 images. These images are divided into two subsets with a ratio of 4:1 for training and testing the improved Faster-RCNN model, respectively. The proposed model is transferred and learned on the pre-training model of MS COCO dataset. In the test experiments, the proposed method achieves an average accuracy of 89% and a recall of 97%. Compared with other Faster-RCNN models, YOLOv3, SSD and RetinaNet, our proposed new method improves the average accuracy by more than 6% and the recall by more than 2%. Furthermore, the new method can detect at 20fps when the input image size is 1024×1024×3 and can also be used for real-time automatic detection of spark plug defects.

29 May 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
YLYuhang Liu
Yuhang Liu
HSHuazhong Shu
Huazhong Shu
YLYi Liu
Yi Liu
PZPengcheng Zhang
Pengcheng Zhang
LWLei Wang
Lei Wang
ZGZhiguo Gui
Zhiguo Gui
Accurate reconstruction of computed laminography (CL) remains challenging due to incomplete projections causing inter-slice aliasing and blurring. In this paper, we propose a novel 3-D CL reconstruction model named SART-SR, which extends traditional single-term regularization methods into a sequential regularization (SR) framework specifically designed for anisotropic CL data. Guided by the theory of "visible and invisible boundaries", this framework decomposes the regularization process into three directional-aware stages: (1) 1-D directional gradient sparsity terms are first applied in the in-slice to enhance reliable edge structures; (2) mild edge-preserving smoothing is applied along the z-direction to reduce aliasing; and (3) a truncated adaptive-weighted total variation (TAwTV) is used for volumetric consistency and streak artifact suppression. To solve the model efficiently, we develop an alternating minimization algorithm based on the Split-Bregman method and gradient descent. The results on simulated MPCB and flange plate phantoms demonstrate that SART-SR notably outperforms competing iterative methods, including simultaneous algebraic reconstruction technique (SART), in preserving edges, suppressing inter-slice aliasing, and reducing noise. The code is publicly available at https://github.com/YuhangLiu98/SART-SR.