The aim of this in vitro study was to determine the sensitivity and specificity of cone-beam computed tomography (CBCT) and digital periapical radiography in the detection of mesial root perforations of mandibular molars. In this in vitro study, 48 mandibular molars were divided into 4 groups. First, the mesial canals of all the 48 teeth were endodontically prepared. In 2 groups (24 teeth each), the roots were axially perforated in the mesiolingual canal 1-3 mm below the furcation region, penetrating the root surface ("root perforation"). Then, in one of these 2 groups, the mesial canals were filled with gutta-percha and AH26 sealer. Mesial canals in one of the other 2 groups without perforation (control groups) were filled with the same materials. The CBCT and periapical radiographs with 3 different angulations were evaluated by 2 oral and maxillofacial radiologists. The specificity and sensitivity of the two methods were calculated, and P<0.05 was considered significant. The sensitivity and specificity of CBCT scans in the detection of obturated root canal perforations were 79% and 96%, respectively, and in the case of three-angled periapical radiographs, they were 92% and 100%, respectively. In non-obturated root canals, the sensitivity and specificity of CBCT scans in perforation detection were 92% and 100%, respectively, and for three-angled periapical radiographs, they were 50% and 96%, respectively. For perforation detection in filled-root canals, periapical radiography with three different horizontal angulations would be trustworthy, but it is recommended that CBCT be used for perforation detection before obturating root canals.
Background: Apical transportation (AT) of the root canal moves the physiologic canal terminus to a new location on the external root surface and results in the accumulation of debris and residual microorganisms due to inadequate cleaning and shaping of the canal end. This study aimed to assess the prevalence of AT following canal preparation with Mtwo and Reciproc R25 using cone-beam computed tomographic (CBCT). Materials and Methods: In this in vitro study, 40 mesiobuccal root canals of the maxillary molars with 19–22 mm length and (>40°) taper were prepared in two groups using Mtwo and Reciproc R25 rotary systems along with irrigation with 2.5% NaOCl. CBCT scans were obtained of the canals before and after preparation under similar conditions, and the values were measured using the device software. The amount of AT was measured according to Gambill et al. Data were analyzed using SPSS 17 and Chi-square and t-tests. P < 0.05 was considered significant. Results: Both systems caused some degrees of AT. No significant difference was found between the two systems in terms of the amount and direction of AT (P > 0.05); overall, the frequency of AT toward the mesial wall was greater than that toward the distal direction. However, this difference was not statistically significant. Conclusion: The mean amount of AT and the ability to keep the instruments in severely curved canals were not significantly different in canals prepared by Mtwo and Reciproc rotary systems. Thus, these systems can be used in the clinical setting with the lowest risk of AT.
External root resorption (ERR) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. The aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (CR) in comparison with digital radiographic techniques, i.e. charge-coupled device (CCD) and photo-stimulable phosphor (PSP) sensors, in detection of ERR. This study was performed on 80 extracted human mandibular premolars. After taking separate initial periapical radiographs with CR technique, CCD and PSP sensors, the artificial defects resembling ERR with variable sizes were created in apical half of the mesial, distal and buccal surfaces of the teeth. Ten teeth were used as control samples without any resorption. The radiographs were then repeated with 2 different exposure times and the images were observed by 3 observers. Data were analyzed using SPSS version 17 and chi-squared and Cohen's Kappa tests with 95% confidence interval (CI=95%). The CCD had the highest percentage of correct assessment compared to the CR and PSP sensors, although the difference was not significant (P=0.39). It was shown that the higher dosage of radiation increases the accuracy of diagnosis; however, it was only significant for CCD sensor (P=0.02). Also, the accuracy of diagnosis increased with the increase in the size of lesion (P=0.001). Statistically significant difference was not observed for accurate detection of ERR by conventional and digital radiographic techniques.