Richard Speight

Richard Speight

Auto-generated profile, based on publicly available information

Richard Speight

Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, Leeds LS9 7TF, United Kingdom

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2015 in BMC Cancer
Verified
Journal Article
Open access
PDF file
DBDavid Bird
David Bird
ASAndrew Scarsbrook
Andrew Scarsbrook
JSJonathan Sykes
Jonathan Sykes
SRSatiavani Ramasamy
Satiavani Ramasamy
MSManil Subesinghe
Manil Subesinghe
RPRobin J D Prestwich
Robin J D Prestwich
This study aimed to quantify the variation in oropharyngeal squamous cell carcinoma gross tumour volume (GTV) delineation between CT, MR and FDG PET-CT imaging. A prospective, single centre, pilot study was undertaken where 11 patients with locally advanced oropharyngeal cancers (2 tonsil, 9 base of tongue primaries) underwent pre-treatment, contrast enhanced, FDG PET-CT and MR imaging, all performed in a radiotherapy treatment mask. CT, MR and CT-MR GTVs were contoured by 5 clinicians (2 radiologists and 3 radiation oncologists). A semi-automated segmentation algorithm was used to contour PET GTVs. Volume and positional analyses were undertaken, accounting for inter-observer variation, using linear mixed effects models and contour comparison metrics respectively. Significant differences in mean GTV volume were found between CT (11.9 cm3) and CT-MR (14.1 cm3), p < 0.006, CT-MR and PET (9.5 cm3), p < 0.0009, and MR (12.7 cm3) and PET, p < 0.016. Substantial differences in GTV position were found between all modalities with the exception of CT-MR and MR GTVs. A mean of 64 %, 74 % and 77 % of the PET GTVs were included within the CT, MR and CT-MR GTVs respectively. A mean of 57 % of the MR GTVs were included within the CT GTV; conversely a mean of 63 % of the CT GTVs were included within the MR GTV. CT inter-observer variability was found to be significantly higher in terms of position and/or volume than both MR and CT-MR (p < 0.05). Significant differences in GTV volume were found between GTV volumes delineated by radiologists (9.7 cm3) and oncologists (14.6 cm3) for all modalities (p = 0.001). The use of different imaging modalities produced significantly different GTVs, with no single imaging technique encompassing all potential GTV regions. The use of MR reduced inter-observer variability. These data suggest delineation based on multimodality imaging has the potential to improve accuracy of GTV definition. ISRCTN Registry: ISRCTN34165059 . Registered 2nd February 2015.

29 April 2021 in British Journal of Radiology
Verified
Journal Article
Open access
MHMohammad Hussein
Mohammad Hussein
AAAdeyemi Akintonde
Adeyemi Akintonde
JMJamie McClelland
Jamie McClelland
RSRichard Speight
Richard Speight
CCCatharine H Clark
Catharine H Clark
Objective: The aim of this study was to evaluate the current status of the clinical use of deformable image registration (DIR) in radiotherapy and to gain an understanding of the challenges faced by centres in clinical implementation of DIR, including commissioning and quality assurance (QA), and to determine the barriers faced. The goal was to inform whether additional guidance and QA tools were needed. Methods: A survey focussed on clinical use, metrics used, how centres would like to use DIR in the future and challenges faced, was designed and sent to 71 radiotherapy centres in the UK. Data were gathered specifically on which centres we using DIR clinically, which applications were being used, what commissioning and QA tests were performed, and what barriers were preventing the integration of DIR into the clinical workflow. Centres that did not use DIR clinically were encouraged to fill in the survey and were asked if they have any future plans and in what timescale. Results: 51 out of 71 (70%) radiotherapy centres responded. 47 centres reported access to a commercial software that could perform DIR. 20 centres already used DIR clinically, and 22 centres had plans to implement an application of DIR within 3 years of the survey. The most common clinical application of DIR was to propagate contours from one scan to another (19 centres). In each of the applications, the types of commissioning and QA tests performed varied depending on the type of application and between centres. Some of the key barriers were determining when a DIR was satisfactory including which metrics to use, and lack of resources. Conclusion: The survey results highlighted that there is a need for additional guidelines, training, better tools for commissioning DIR software and for the QA of registration results, which should include developing or recommending which quantitative metrics to use. Advances in knowledge: This survey has given a useful picture of the clinical use and lack of use of DIR in UK radiotherapy centres. The survey provided useful insight into how centres commission and QA DIR applications, especially the variability among centres. It was also possible to highlight key barriers to implementation and determine factors that may help overcome this which include the need for additional guidance specific to different applications, better tools and metrics.

25 February 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
RSRichard Speight
Richard Speight
MDMichael Dubec
Michael Dubec
CECynthia L Eccles
Cynthia L Eccles
BGBen George
Ben George
AHAnn Henry
Ann Henry
MSMaria A Schmidt
Maria A Schmidt
This document gives guidance for multidisciplinary teams within institutions setting up and using an MRI-guided radiotherapy (RT) treatment planning service. It has been written by a multidisciplinary working group from the Institute of Physics and Engineering in Medicine (IPEM). Guidance has come from the experience of the institutions represented in the IPEM working group, in consultation with other institutions, and where appropriate references are given for any relevant legislation, other guidance documentation and information in the literature. Guidance is only given for MRI acquired for external beam RT treatment planning in a CT-based workflow, i.e. when MRI is acquired and registered to CT with the purpose of aiding delineation of target or organ at risk volumes. MRI use for treatment response assessment, MRI-only RT and other RT treatment types such as brachytherapy and gamma radiosurgery are not considered within the scope of this document. The aim was to produce guidance that will be useful for institutions who are setting up and using a dedicated MR scanner for RT (referred to as an MR-sim) and those who will have limited time on an MR scanner potentially managed outside of the RT department, often by radiology. Although not specifically covered in this document, there is an increase in the use of hybrid MRI-linac systems worldwide and brief comments are included to highlight any crossover with the early implementation of this technology. In this document, advice is given on introducing a RT workload onto a non-RT-dedicated MR scanner, as well as planning for installation of an MR scanner dedicated for RT. Next, practical guidance is given on the following, in the context of RT planning: training and education for all staff working in and around an MR scanner; RT patient set-up on an MR scanner; MRI sequence optimisation for RT purposes; commissioning and quality assurance (QA) to be performed on an MR scanner; and MRI to CT registration, including commissioning and QA.

8 July 2016 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KWKieran Wardman
Kieran Wardman
RPRobin J.D. Prestwich
Robin J.D. Prestwich
MGMark J. Gooding
Mark J. Gooding
RSRichard J. Speight
Richard J. Speight
Atlas-based autosegmentation is an established tool for segmenting structures for CT-planned head and neck radiotherapy. MRI is being increasingly integrated into the planning process. The aim of this study is to assess the feasibility of MRI-based, atlas-based autosegmentation for organs at risk (OAR) and lymph node levels, and to compare the segmentation accuracy with CT-based autosegmentation. Fourteen patients with locally advanced head and neck cancer in a prospective imaging study underwent a T1-weighted MRI and a PET-CT (with dedicated contrast-enhanced CT) in an immobilization mask. Organs at risk (orbits, parotids, brainstem, and spinal cord) and the left level II lymph node region were manually delineated on the CT and MRI separately. A ‘leave one out’ approach was used to automatically segment structures onto the remaining images separately for CT and MRI. Contour comparison was performed using multiple positional metrics: Dice index, mean distance to conformity (MDC), sensitivity index (Se Idx), and inclusion index (Incl Idx). Automatic segmentation using MRI of orbits, parotids, brainstem, and lymph node level was acceptable with a DICE coefficient of 0.73?0.91 , MDC 2.0?5.1?mm , Se Idx 0.64?0.93 , Incl Idx 0.76?0.93. Segmentation of the spinal cord was poor (Dice coefficient 0.37). The process of automatic segmentation was significantly better on MRI compared to CT for orbits, parotid glands, brainstem, and left lymph node level II by multiple positional metrics; spinal cord segmentation based on MRI was inferior compared with CT. Accurate atlas-based automatic segmentation of OAR and lymph node levels is feasible using T1-MRI; segmentation of the spinal cord was found to be poor. Comparison with CT-based automatic segmentation suggests that the process is equally as, or more accurate, using MRI. These results support further translation of MRI-based segmentation methodology into clinical practice. PACS number(s): 87.55.de

1 September 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
RSRichard Speight
Richard Speight
MSMaria A Schmidt
Maria A Schmidt
GLGary P Liney
Gary P Liney
RJRobert I Johnstone
Robert I Johnstone
CECynthia L Eccles
Cynthia L Eccles
HMHazel Mhairi McCallum
Hazel Mhairi McCallum
The benefits of integrating MRI into the radiotherapy pathway are well published, however there is little consensus in guidance on how to commission or implement its use. With a view to developing consensus guidelines for the use of MRI in external beam radiotherapy (EBRT) treatment planning in the UK, a survey was undertaken by an Institute of Physics and Engineering in Medicine (IPEM) working-party to assess the current landscape of MRI use in EBRT in the UK. A multi-disciplinary working-party developed a survey to understand current practice using MRI for EBRT treatment planning; investigate how MRI is currently used and managed; and identify knowledge gaps. The survey was distributed electronically to radiotherapy service managers and physics leads in 71 UK radiotherapy (RT) departments (all NHS and private groups). The survey response rate was 87% overall, with 89% of NHS and 75% of private centres responding. All responding centres include EBRT in some RT pathways: 94% using Picture Archiving and Communication System (PACS) images potentially acquired without any input from RT departments, and 69% had some form of MRI access for planning EBRT. Most centres reporting direct access use a radiology scanner within the same hospital in dedicated (26%) or non-dedicated (52%) RT scanning sessions. Only two centres reported having dedicated RT MRI scanners in the UK, lower than reported in other countries. Six percent of radiotherapy patients in England (data not publically available outside of England) have MRI as part of their treatment, which again is lower than reported elsewhere. Although a substantial number of centres acquire MRI scans for treatment planning purposes, most centres acquire less than five patient scans per month for each treatment site. Commissioning and quality assurance of both image registration and MRI scanners was found to be variable across the UK. In addition, staffing models and training given to different staff groups varied considerably across the UK, reflecting the current lack of national guidelines. The primary barriers reported to MRI implementation in EBRT planning included costs (e.g. lack of a national tariff for planning MRI), lack of MRI access and/or capacity within hospitals. Despite these challenges, significant interest remains in increasing MRI-assisted EBRT planning over the next five years.

4 February 2009 in Physical Review B
Verified
Journal Article
Closed access
PDF file
RSR. Speight
R. Speight
AWAlan Wong
Alan Wong
PEP. Ellis
P. Ellis
PBP. T. Bishop
P. T. Bishop
THTimothy Hyde
Timothy Hyde
MSMark Smith
Mark Smith
To demonstrate the potential of nuclear-magnetic-resonance (NMR) spectroscopy in investigating detailed structural properties in ferromagnetic materials, the allotropic phase transformation of polycrystalline cobalt with μm particle size (<2 μm) is characterized by internal-field C59o NMR. The C59o NMR spectra show distinct resonance bands corresponding to the different Co sites: face-centered cubic (fcc), hexagonal-close packed (hcp), and stacking faults (sfs), in Co metal powder. The hcp→fcc phase-transition temperature is determined by systematically monitoring the signal intensity of each Co environment in a series of heat-treated Co powders. The potential limits to which absolute quantification of the different sites can be pushed are mentioned, with relative changes in intensity giving unequivocal evidence of the structural evolution. For example, the phase-transition temperature is observed to be 500±25 °C, and above this temperature, the sf Co sites were reduced by more than 10%.