Jeremy Speth

Jeremy Speth

Auto-generated profile, based on publicly available information

Jeremy Speth

University of Notre Dame

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Computer Vision and Image Understanding
Verified
Journal Article
Closed access
JSJeremy Speth
Jeremy Speth
NVNathan Vance
Nathan Vance
PFPatrick Flynn
Patrick Flynn
KBKevin Bowyer
Kevin Bowyer
ACAdam Czajka
Adam Czajka

9 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JSJeremy Speth
Jeremy Speth
NVNathan R. Vance
Nathan R. Vance
BSBenjamin Sporrer
Benjamin Sporrer
LNLu Niu
Lu Niu
PFPatrick Flynn
Patrick Flynn
ACAdam Czajka
Adam Czajka
Visible-light cameras can capture subtle physiological biomarkers without physical contact with the subject. We present the Multi-Site Physiological Monitoring (MSPM) dataset, which is the first dataset collected to support the study of simultaneous camera-based vital signs estimation from multiple locations on the body. MSPM enables research on remote photoplethysmography (rPPG), respiration rate, and pulse transit time (PTT); it contains ground-truth measurements of pulse oximetry (at multiple body locations) and blood pressure using contact sensors. We provide thorough experiments demonstrating the suitability of MSPM to support research on rPPG, respiration rate, and PTT. Cross-dataset rPPG experiments reveal that MSPM is a challenging yet high quality dataset, with intra-dataset pulse rate mean absolute error (MAE) below 4 beats per minute (BPM), and cross-dataset pulse rate MAE below 2 BPM in certain cases. Baseline methods for respiratory rate estimation achieve an MAE of 1.09 breaths per minute by extracting motion features from the chest. PTT experiments find that across the pairs of different body sites, there is high correlation between remote PTT and contact-measured PTT, which facilitates the possibility for future camera-based PTT research.

11 March 2023 in arXiv
Verified
Preprint
Open access
PDF file
JSJeremy Speth
Jeremy Speth
NVNathan Vance
Nathan Vance
BSBenjamin Sporrer
Benjamin Sporrer
LNLu Niu
Lu Niu
PFPatrick Flynn
Patrick Flynn
ACAdam Czajka
Adam Czajka
Camera-based physiological monitoring, especially remote photoplethysmography (rPPG), is a promising tool for health diagnostics, and state-of-the-art pulse estimators have shown impressive performance on benchmark datasets. We argue that evaluations of modern solutions may be incomplete, as we uncover failure cases for videos without a live person, or in the presence of severe noise. We demonstrate that spatiotemporal deep learning models trained only with live samples "hallucinate" a genuine-shaped pulse on anomalous and noisy videos, which may have negative consequences when rPPG models are used by medical personnel. To address this, we offer: (a) An anomaly detection model, built on top of the predicted waveforms. We compare models trained in open-set (unknown abnormal predictions) and closed-set (abnormal predictions known when training) settings; (b) An anomaly-aware training regime that penalizes the model for predicting periodic signals from anomalous videos. Extensive experimentation with eight research datasets (rPPG-specific: DDPM, CDDPM, PURE, UBFC, ARPM; deep fakes: DFDC; face presentation attack detection: HKBU-MARs; rPPG outlier: KITTI) show better accuracy of anomaly detection for deep learning models incorporating the proposed training (75.8%), compared to models trained regularly (73.7%) and to hand-crafted rPPG methods (52-62%).

16 March 2023 in arXiv
Verified
Preprint
Open access
PDF file
LNLu Niu
Lu Niu
JSJeremy Speth
Jeremy Speth
NVNathan Vance
Nathan Vance
BSBenjamin Sporrer
Benjamin Sporrer
ACAdam Czajka
Adam Czajka
PFPatrick Flynn
Patrick Flynn
Remote photoplethysmography (rPPG) allows for noncontact monitoring of blood volume changes from a camera by detecting minor fluctuations in reflected light. Prior applications of rPPG focused on face videos. In this paper we explored the feasibility of rPPG from non-face body regions such as the arms, legs, and hands. We collected a new dataset titled Multi-Site Physiological Monitoring (MSPM), which will be released with this paper. The dataset consists of 90 frames per second video of exposed arms, legs, and face, along with 10 synchronized PPG recordings. We performed baseline heart rate estimation experiments from non-face regions with several state-of-the-art rPPG approaches, including chrominance-based (CHROM), plane-orthogonal-to-skin (POS) and RemotePulseNet (RPNet). To our knowledge, this is the first evaluation of the fidelity of rPPG signals simultaneously obtained from multiple regions of a human body. Our experiments showed that skin pixels from arms, legs, and hands are all potential sources of the blood volume pulse. The best-performing approach, POS, achieved a mean absolute error peaking at 7.11 beats per minute from non-facial body parts compared to 1.38 beats per minute from the face. Additionally, we performed experiments on pulse transit time (PTT) from both the contact PPG and rPPG signals. We found that remote PTT is possible with moderately high frame rate video when distal locations on the body are visible. These findings and the supporting dataset should facilitate new research on non-face rPPG and monitoring blood flow dynamics over the whole body with a camera.

20 April 2024 in arXiv
Verified
Preprint
Open access
PDF file
JSJeremy Speth
Jeremy Speth
NVNathan Vance
Nathan Vance
PFPatrick Flynn
Patrick Flynn
ACAdam Czajka
Adam Czajka
Subtle periodic signals, such as blood volume pulse and respiration, can be extracted from RGB video, enabling noncontact health monitoring at low cost. Advancements in remote pulse estimation -- or remote photoplethysmography (rPPG) -- are currently driven by deep learning solutions. However, modern approaches are trained and evaluated on benchmark datasets with ground truth from contact-PPG sensors. We present the first non-contrastive unsupervised learning framework for signal regression to mitigate the need for labelled video data. With minimal assumptions of periodicity and finite bandwidth, our approach discovers the blood volume pulse directly from unlabelled videos. We find that encouraging sparse power spectra within normal physiological bandlimits and variance over batches of power spectra is sufficient for learning visual features of periodic signals. We perform the first experiments utilizing unlabelled video data not specifically created for rPPG to train robust pulse rate estimators. Given the limited inductive biases, we successfully applied the same approach to camera-based respiration by changing the bandlimits of the target signal. This shows that the approach is general enough for unsupervised learning of bandlimited quasi-periodic signals from different domains. Furthermore, we show that the framework is effective for finetuning models on unlabelled video from a single subject, allowing for personalized and adaptive signal regressors.

20 May 2021 in arXiv
Verified
Preprint
Open access
PDF file
JSJeremy Speth
Jeremy Speth
NVNathan Vance
Nathan Vance
PFPatrick Flynn
Patrick Flynn
KBKevin Bowyer
Kevin Bowyer
ACAdam Czajka
Adam Czajka
Remote photoplethysmography (rPPG), a family of techniques for monitoring blood volume changes, may be especially useful for widespread contactless health monitoring using face video from consumer-grade visible-light cameras. The COVID-19 pandemic has caused the widespread use of protective face masks. We found that occlusions from cloth face masks increased the mean absolute error of heart rate estimation by more than 80\% when deploying methods designed on unmasked faces. We show that augmenting unmasked face videos by adding patterned synthetic face masks forces the model to attend to the periocular and forehead regions, improving performance and closing the gap between masked and unmasked pulse estimation. To our knowledge, this paper is the first to analyse the impact of face masks on the accuracy of pulse estimation and offers several novel contributions: (a) 3D CNN-based method designed for remote photoplethysmography in a presence of face masks, (b) two publicly available pulse estimation datasets acquired from 86 unmasked and 61 masked subjects, (c) evaluations of handcrafted algorithms and a 3D CNN trained on videos of unmasked faces and with masks synthetically added, and (d) data augmentation method to add a synthetic mask to a face video.