14 June 2024 in Nature Medicine
In solid tumor oncology, circulating tumor DNA (ctDNA) is poised to transform care through accurate assessment of minimal residual disease (MRD) and therapeutic response monitoring. To overcome the sparsity of ctDNA fragments in low tumor fraction (TF) settings and increase MRD sensitivity, we previously leveraged genome-wide mutational integration through plasma whole-genome sequencing (WGS). Here we now introduce MRD-EDGE, a machine-learning-guided WGS ctDNA single-nucleotide variant (SNV) and copy-number variant (CNV) detection platform designed to increase signal enrichment. MRD-EDGESNV uses deep learning and a ctDNA-specific feature space to increase SNV signal-to-noise enrichment in WGS by ~300× compared to previous WGS error suppression. MRD-EDGECNV also reduces the degree of aneuploidy needed for ultrasensitive CNV detection through WGS from 1 Gb to 200 Mb, vastly expanding its applicability within solid tumors. We harness the improved performance to identify MRD following surgery in multiple cancer types, track changes in TF in response to neoadjuvant immunotherapy in lung cancer and demonstrate ctDNA shedding in precancerous colorectal adenomas. Finally, the radical signal-to-noise enrichment in MRD-EDGESNV enables plasma-only (non-tumor-informed) disease monitoring in advanced melanoma and lung cancer, yielding clinically informative TF monitoring for patients on immune-checkpoint inhibition.
6 November 2018 in Science Signaling
Inhibitors of soluble adenylyl cyclase increase pigmentation and may reduce the risk of skin cancer.
1 October 2022 in Journal of the National Comprehensive Cancer Network
Background: Whether COVID-19 vaccination and the associated immune response increases susceptibility to immune-related adverse events (irAEs) among patients treated with immune checkpoint inhibition (ICI) remains unknown. Short-term follow-up can assess the safety of concurrent administration of the vaccine and ICI treatment. Methods: We conducted an electronic health record analysis of a cohort of 408 patients with cancer receiving ICI therapy and who were vaccinated for COVID-19 between January 16 and March 27, 2021. Patients were seen in follow-up for 90 days from the day of the first dose in this single-institution tertiary care center. We evaluated the incidence of irAEs and the frequency of each event type and grade among patients who experienced an irAE. We also evaluated the incidence of irAEs in patients who began a new immunotherapy agent after vaccination. Results: Among 408 patients with cancer receiving ICI therapy (median age, 71 years; 217 [53%] male), administration of a COVID-19 mRNA vaccine within 90 days of ICI treatment was not associated with an increased incidence of irAEs. A total of 27 (7%) patients experienced a new irAE within the observation period. Among patients with previous irAEs from ICIs (n=54), 3 (6%) experienced a recurrent irAE, and of those initiating a new immunotherapy (n=52), 9 (17%) experienced an irAE. No excess risk of COVID-19 diagnosis was seen in this subset of patients receiving ICI therapy, and no breakthrough COVID-19 cases were seen after full COVID-19 vaccination. Conclusions: These findings should reassure providers that COVID-19 vaccination during ICI therapy is safe and efficacious.
20 January 2022 in bioRxiv
In solid tumor oncology, circulating tumor DNA (ctDNA) is poised to transform care through accurate assessment of minimal residual disease (MRD) and therapeutic response monitoring. To overcome the sparsity of ctDNA fragments in low tumor fraction (TF) settings and increase MRD sensitivity, we previously leveraged genome-wide mutational integration through plasma whole genome sequencing (WGS). We now introduce MRD-EDGE, a composite machine learning-guided WGS ctDNA single nucleotide variant (SNV) and copy number variant (CNV) detection platform designed to increase signal enrichment. MRD-EDGE uses deep learning and a ctDNA-specific feature space to increase SNV signal to noise enrichment in WGS by 300X compared to our previous noise suppression platform MRDetect. MRD-EDGE also reduces the degree of aneuploidy needed for ultrasensitive CNV detection through WGS from 1Gb to 200Mb, thereby expanding its applicability to a wider range of solid tumors. We harness the improved performance to track changes in tumor burden in response to neoadjuvant immunotherapy in non-small cell lung cancer and demonstrate ctDNA shedding in precancerous colorectal adenomas. Finally, the radical signal to noise enrichment in MRD-EDGE enables de novo mutation calling in melanoma without matched tumor, yielding clinically informative TF monitoring for patients on immune checkpoint inhibition.
17 November 2022 in bioRxiv
Circulating cell-free DNA (ccfDNA) sequencing for low-burden cancer monitoring is limited by sparsity of circulating tumor DNA (ctDNA), the abundance of genomic material within a plasma sample, and pre-analytical error rates due to library preparation, and sequencing errors. Sequencing costs have historically favored the development of deep targeted sequencing approaches for overcoming sparsity in ctDNA detection, but these techniques are limited by the abundance of ccfDNA in samples, which imposes a ceiling on the maximal depth of coverage in targeted panels. Whole genome sequencing (WGS) is an orthogonal approach to ctDNA detection that can overcome the low abundance of ccfDNA by supplanting sequencing depth with breadth, integrating signal across the entire tumor mutation landscape. However, the higher cost of WGS limits the practical depth of coverage and hinders broad adoption. Lower sequencing costs may thus allow for enhanced ctDNA cancer monitoring via WGS. We therefore applied emerging lower-cost WGS (Ultima Genomics, 1USD/Gb) to plasma samples at ∼120x coverage. Copy number and single nucleotide variation profiles were comparable between matched Ultima and Illumina datasets, and the deeper WGS coverage enabled ctDNA detection at the parts per million range. We further harnessed these lower sequencing costs to implement duplex error-corrected sequencing at the scale of the entire genome, demonstrating a ∼1,500x decrease in errors in the plasma of patient-derived xenograft mouse models, and error rates of ∼10 −7 in patient plasma samples. We leveraged this highly de-noised plasma WGS to undertake cancer monitoring in the more challenging context of resectable melanoma without matched tumor sequencing. In this context, duplex-corrected WGS allowed us to harness known mutational signature patterns for disease monitoring without matched tumors, paving the way for de novo cancer monitoring.
14 August 2025 in bioRxiv
Distinguishing real biological variation in the form of single-nucleotide variants (SNVs) from errors is a major challenge for genome sequencing technologies. This is particularly true in settings where SNVs are at low frequency such as cancer detection through liquid biopsy, or human somatic mosaicism. State-of-the-art molecular denoising approaches for DNA sequencing rely on duplex sequencing, where both strands of a single DNA molecule are sequenced to discern true variants from errors arising from single stranded DNA damage. However, such duplex approaches typically require massive over-sequencing to overcome low capture rates of duplex molecules. To address these challenges, we introduce paired plus-minus sequencing (ppmSeq) technology, in which both DNA strands are partitioned and clonally amplified on sequencing beads through emulsion PCR. In this reaction, both strands of a double-stranded DNA molecule contribute to a single sequencing read, allowing for a duplex yield that scales linearly with sequencing coverage across a wide range of inputs (1.8-98 ng). We benchmarked ppmSeq against current duplex sequencing technologies, demonstrating superior duplex recovery with ppmSeq, with a rate of 44%±5.5% (compared to ∼5-11% for leading duplex technologies). Using both genomic as well as cell-free DNA, we established error rates for ppmSeq, which had residual SNV detection error rates as low as 7.98×10 -8 for gDNA (using an end-repair protocol with dideoxy nucleotides) and 3.5×10 -7 ±7.5×10 -8 for cell-free DNA. To test the capabilities of ppmSeq for error-corrected whole-genome sequencing (WGS) for clinical application, we assessed circulating tumor DNA (ctDNA) detection for disease monitoring in cancer patients. We demonstrated that ppmSeq enables powerful tumor-informed ctDNA detection at concentrations of 10 -4 across most cancers, parts per million sensitivity in cancers with high mutation burden, and further increased sensitivity with higher sequencing depth. We then leveraged genome-wide trinucleotide mutation patterns characteristic of urothelial (APOBEC3-related and platinum exposure-related signatures) and lung (tobacco-exposure-related signatures) cancers to perform tumor-naive ctDNA detection, showing that ppmSeq can identify a disease-specific signal in plasma cell-free DNA without a matched tumor, and that this signal correlates with imaging-based disease metrics. Altogether, ppmSeq provides an error-corrected, cost-efficient and scalable approach for high-fidelity WGS that can be harnessed for challenging clinical applications and emerging frontiers in human somatic genetics where high accuracy is required for mutation identification.