12 April 2012 in Magnetic Resonance in Medicine
This work demonstrates a fast, sensitive method of characterizing the dynamic performance of MR gradient systems. The accuracy of gradient time‐courses is often compromised by field imperfections of various causes, including eddy currents and mechanical oscillations. Characterizing these perturbations is instrumental for corrections by pre‐emphasis or post hoc signal processing. Herein, a gradient chain is treated as a linear time‐invariant system, whose impulse response function is determined by measuring field responses to known gradient inputs. Triangular inputs are used to probe the system and response measurements are performed with a dynamic field camera consisting of NMR probes. In experiments on a whole‐body MR system, it is shown that the proposed method yields impulse response functions of high temporal and spectral resolution. Besides basic properties such as bandwidth and delay, it also captures subtle features such as mechanically induced field oscillations. For validation, measured response functions were used to predict gradient field evolutions, which was achieved with an error below 0.2%. The field camera used records responses of various spatial orders simultaneously, rendering the method suitable also for studying cross‐responses and dynamic shim systems. It thus holds promise for a range of applications, including pre‐emphasis optimization, quality assurance, and image reconstruction. Magn Reson Med, 2013.
14 May 2015 in Magnetic Resonance in Medicine
Purpose: MR image formation and interpretation relies on highly accurate dynamic magnetic fields of high fidelity. A range of mechanisms still limit magnetic field fidelity, including magnet drifts, eddy currents, and finite linearity and stability of power amplifiers used to drive gradient and shim coils. Addressing remaining errors by means of hardware, sequence, or signal processing optimizations, calls for immediate observation by magnetic field monitoring. The present work presents a stand‐alone monitoring system delivering insight into such field imperfections for MR sequence and system analysis.Methods: A flexible NMR field probe‐based stand‐alone monitoring system, built on a software‐defined‐radio approach, is introduced and used to sense field dynamics up to third‐order in space in a selection of situations with different time scales.Results: Highly sensitive trajectories are measured and successfully used for image reconstruction. Further field perturbations due to mechanical oscillations and thermal field drifts following demanding gradient use and external interferences are studied.Conclusion: A flexible and versatile monitoring system is presented, delivering camera‐like access to otherwise hardly accessible field dynamics with nanotesla resolution. Its stand‐alone nature enables field analysis even during unknown MR system states. Magn Reson Med 75:1831–1840, 2016. © 2015 Wiley Periodicals, Inc.
1 March 2018 in NeuroImage
27 July 2015 in Magnetic Resonance in Medicine
5 June 2014 in Magnetic Resonance in Medicine
Purpose Magnetic field fluctuations caused by subject motion, such as breathing or limb motion, can degrade image quality in brain MRI, especially at high field strengths. The purpose of this study was to investigate the feasibility of retrospectively correcting for such physiological field perturbations based on concurrent field monitoring. Theory and Methods High-resolution T2*-weighted gradient-echo images of the brain were acquired at 7T with subjects performing different breathing and hand movement patterns. Field monitoring with a set of 19F NMR probes distributed around the head was performed in two variants: concurrently with imaging or as a single field measurement per readout. The measured field fluctuations were then accounted for in the image reconstruction. Results Significant field fluctuations due to motion were observed in all subjects, resulting in severe artifacts in uncorrected images. The artifacts were largely removed by reconstruction based on field monitoring. Accounting for field perturbations up to the 1st spatial order was generally sufficient to recover good image quality. Conclusions It has been demonstrated that artifacts due to physiologically induced dynamic field perturbations can be greatly reduced by retrospective image correction based on field monitoring. The necessity to perform such correction is greatest at high fields and for field-sensitive techniques such as T2*-weighted imaging. Magn Reson Med 73:1833–1843, 2015.
21 October 2016 in Magnetic Resonance in Medicine