5 August 2016 in Pediatric Radiology
3 February 2017 in Journal of Magnetic Resonance Imaging
23 June 2014 in NMR in Biomedicine
7 March 2019 in European Respiratory Journal
Background: Early detection of pulmonary morbidity following haematopoietic stem cell transplantation (HSCT) remains an important challenge for intervention, primarily due to the insensitivity of spirometry to early change, and in paediatrics, patient compliance provides additional challenges. Regional lung ventilation abnormalities in paediatric HSCT patients were quantified using hyperpolarised xenon-129 (129Xe) magnetic resonance imaging (MRI) and compared to spirometry.Methods: Medically stable, paediatric allogeneic HSCT patients (n=23, ages 6–16 years) underwent an outpatient MRI scan where regional ventilation was quantified with a breath-hold of hyperpolarised129Xe gas. Ventilation deficits, regions of the lung that ventilate poorly due to obstruction, were quantified as a ventilation defect percentage (VDP) and compared to forced expiratory volume in 1 s (FEV1), FEV1/forced vital capacity (FVC) ratio, and forced expiratory flow at 25–75% of FVC (FEF25–75%) from spirometry using linear regression.Results: The mean±sd129Xe VDP was 10.5±9.4% (range 2.6–41.4%).129Xe VDP correlated with FEV1, FEV1/FVC ratio and FEF25–75%(p≤0.02 for all comparisons). Ventilation deficits were detected in patients with normal spirometry (i.e.FEV1>80%), supporting the sensitivity of129Xe MRI to early obstruction reported in other pulmonary conditions. Seven (30%) patients could not perform spirometry, yet ventilation deficits were observed in five of these patients, detecting abnormalities that otherwise may have gone undetected and untreated until advanced.Conclusion: Lung ventilation deficits were detected using hyperpolarised129Xe gas MRI in asymptomatic paediatric HSCT patients and in a subgroup who were unable to perform reliable spirometry.129Xe MRI provides a reliable imaging-based assessment of pulmonary involvement in this potentially difficult to diagnose paediatric population.
1 August 2019 in Annals of the American Thoracic Society
Rationale: Lymphangioleiomyomatosis (LAM) is a rare disease associated with cystic destruction of the pulmonary parenchyma and chronic respiratory failure, and there are trials underway to determine if early intervention can prevent disease progression. An imaging technique that is sensitive to early regional disease would therefore be valuable for patient care and clinical trials. Objectives: We postulated that hyperpolarized 129Xe MRI would be sensitive to ventilation abnormalities and alveolar airspace dilation in patients with mild LAM disease and normal pulmonary function and that 129Xe MRI would reveal important features of cyst ventilation. Methods: 129Xe ventilation and diffusion-weighted MR images were acquired in 22 patients with LAM during two breath-holds of hyperpolarized 129Xe. 129Xe ventilation defect percentage (VDP; percentage of voxels <60% of the mean whole-lung 129Xe MRI signal) and apparent diffusion coefficient (ADC), a measure of alveolar airspace size, were quantified and compared with pulmonary function test parameters with Spearman statistics. Sixteen patients with LAM had a recent, clinical chest computed tomography (CT) scan available, and cyst ventilation was assessed by thresholding cysts on the CT images and registration to the 129Xe ventilation images. Results: Ventilation deficits were observed in all patients with LAM, including those with normal pulmonary function and few cysts, and the mean VDP was 19.2% (95% confidence interval [CI], 14.8–23.5%). 129Xe VDP was strongly correlated with forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC) ratio (r = −0.51, P = 0.02) and diffusing capacity of the lung for carbon monoxide (DlCO) (r = −0.60, P = 0.009) but not with FEV1 (r = −0.33, P = 0.13), likely because of the sensitivity of 129Xe MRI to mild LAM disease in patients with normal FEV1. The mean ADC was 0.048 cm2/s (95% CI, 0.042–0.053 cm2/s). In many cases, ADC was elevated relative to previously reported values in adults, and ADC was correlated with FEV1, FEV1/FVC ratio, and DlCO (P ≤ 0.02 for all). Co-registered 129Xe MRI and CT imaging revealed considerable ventilation heterogeneity within individual patients with LAM and across patients with similarly sized cysts. Conclusions: 129Xe MRI provides a means to assess the complex regional ventilation and alveolar airspace size changes of LAM with high sensitivity and may be a clinically useful future tool for screening, managing patients, and measuring treatment efficacy.
13 November 2022 in Magnetic Resonance in Medicine
Purpose: Xenon‐129 (129Xe) gas‐exchange MRI is a pulmonary‐imaging technique that provides quantitative metrics for lung structure and function and is often compared to pulmonary‐function tests. Unlike such tests, it does not normalize to predictive values based on demographic variables such as age. Many sites have alluded to an age dependence in gas‐exchange metrics; however, a procedure for normalizing metrics has not yet been introduced.Theory: We model healthy reference values for 129Xe gas‐exchange MRI against age using generalized additive models for location, scale, and shape (GAMLSS). GAMLSS takes signal data from an aggregated heathy‐reference cohort and fits a distribution with flexible median, variation, skewness, and kurtosis to predict age‐dependent centiles. This approach mirrors methods by the Global Lung Function Initiative for modeling pulmonary‐function test data and applies it to binning methods widely used by the 129Xe MRI community to interpret and quantify gas‐exchange data.Methods: Ventilation, membrane‐uptake, red blood cell transfer, and red blood cell:membrane gas‐exchange metrics were collected on 30 healthy subjects over an age range of 5 to 68 years. A GAMLSS model was fit against age and compared against widely used linear and generalized‐linear binning 129Xe MRI analysis schemes.Results: All 4 gas‐exchange metrics had significant skewness, and membrane‐uptake had significant kurtosis compared to a normal distribution. Age has significant impact on distribution parameters. GAMLSS‐binning produced narrower bins compared to the linear and generalized‐linear binning schemes and distributed signal data closer to a normal distribution.Conclusion: The proposed “proof‐of‐concept” GAMLSS‐binning approach can improve diagnostic accuracy of 129Xe gas‐exchange MRI by providing a means of modeling voxel distribution data against age.