Michael D. Diodato

Michael D. Diodato

Auto-generated profile, based on publicly available information

Michael D. Diodato

University of Connecticut, Hartford Hospital, Division of Surgical Critical Care, 80 Seymour Street, Hartford, CT 06102-5037, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2014 in Surgery Research and Practice
Verified
Journal Article
Open access
PDF file
MDMichael Diodato
Michael Diodato
ECEdgar G. Chedrawy
Edgar G. Chedrawy
The development of the heart-lung machine ushered in the era of modern cardiac surgery. Coronary artery bypass graft surgery (CABG) remains the most common operation performed by cardiac surgeons today. From its infancy in the 1950s till today, CABG has undergone many developments both technically and clinically. Improvements in intraoperative technique and perioperative care have led to CABG being offered to a more broad patient profile with less complications and adverse events. Our review outlines the rich history and promising future of myocardial revascularization.

29 August 2005 in The Heart Surgery Forum
Verified
Journal Article
Closed access
PDF file
SGSydney L. Gaynor
Sydney L. Gaynor
GBGregory D. Byrd
Gregory D. Byrd
MDMichael D. Diodato
Michael D. Diodato
YIYosuke Ishii
Yosuke Ishii
ALAnson M. Lee
Anson M. Lee
RJRalph J. Damiano Jr.
Ralph J. Damiano Jr.
Introduction: Microwave ablation has been used clinically for the surgical treatment of atrial fibrillation, particularly during valve procedures. However, dose- response curves have not been established for this surgical environment. The purpose of this study was to examine dosimetry curves for the Flex 4 and Flex 10 microwave devices in an acute cardioplegia-arrested porcine model. Methods: Twelve domestic pigs (40-45 kg) were acutely subjected to Flex 4 (n = 6) and Flex 10 (n = 6) ablations. On a cardioplegically arrested heart maintained at 10-15oC, six endocardial atrial and seven epicardial ventricular lesions were created in each animal. Ablations were performed for 15 s, 30 s, 45 s, 60 s, 90 s, 120 s, and 150 s (65 W, 2.45 GHz). The tissue was stained with 2,3,5-triphenyl-tetrazolium chloride and lesions were sectioned at 5 mm intervals. Lesion depth and width were determined from digital photomicrographs of each lesion (resolution .03 mm). Results: Average atrial thickness was 2.88 .4 mm (range 1.0 to 8.0 mm). 94% of ablated atrial sections created by the FLEX 4 (n = 16) and the FLEX 10 (n = 16) were transmural at 45 seconds. 100% of atrial sections were transmural at 90 seconds with the FLEX 10 (n = 14) and at 60 seconds with the Flex 4 device (n = 15). Lesion width and depth increased with duration of application. Conclusion: Both devices were capable of producing transmural lesions on the cardioplegically arrested heart at 65 W. These curves will allow surgeons to ensure transmural ablation by tailoring energy delivery to the specific atrial geometry.