Keyi Han

Keyi Han

Auto-generated profile, based on publicly available information

Keyi Han

Laboratory for Systems Biophotonics, Georgia Institute of Technology, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2024 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
ARAfsane Radmand
Afsane Radmand
HKHyejin Kim
Hyejin Kim
JBJared Beyersdorf
Jared Beyersdorf
CDCurtis N. Dobrowolski
Curtis N. Dobrowolski
RZRyan Zenhausern
Ryan Zenhausern
JDJames E. Dahlman
James E. Dahlman
Adding a cationic helper lipid to a lipid nanoparticle (LNP) can increase lung delivery and decrease liver delivery. However, it remains unclear whether charge-dependent tropism is universal or, alternatively, whether it depends on the component that is charged. Here, we report evidence that cationic cholesterol-dependent tropism can differ from cationic helper lipid-dependent tropism. By testing how 196 LNPs delivered mRNA to 22 cell types, we found that charged cholesterols led to a different lung:liver delivery ratio than charged helper lipids. We also found that combining cationic cholesterol with a cationic helper lipid led to mRNA delivery in the heart as well as several lung cell types, including stem cell-like populations. These data highlight the utility of exploring charge-dependent LNP tropism.

4 March 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
XHXuanwen Hua
Xuanwen Hua
KHKeyi Han
Keyi Han
BMBiagio Mandracchia
Biagio Mandracchia
ARAfsane Radmand
Afsane Radmand
WLWenhao Liu
Wenhao Liu
SJShu Jia
Shu Jia
Imaging flow cytometry (IFC) combines flow cytometry and fluorescence microscopy to enable high-throughput, multiparametric single-cell analysis with rich spatial details. However, current IFC techniques remain limited in their ability to reveal subcellular information with a high 3D resolution, throughput, sensitivity, and instrumental simplicity. In this study, we introduce a light-field flow cytometer (LFC), an IFC system capable of high-content, single-shot, and multi-color acquisition of up to 5,750 cells per second with a near-diffraction-limited resolution of 400-600 nm in all three dimensions. The LFC system integrates optical, microfluidic, and computational strategies to facilitate the volumetric visualization of various 3D subcellular characteristics through convenient access to commonly used epi-fluorescence platforms. We demonstrate the effectiveness of LFC in assaying, analyzing, and enumerating intricate subcellular morphology, function, and heterogeneity using various phantoms and biological specimens. The advancement offered by the LFC system presents a promising methodological pathway for broad cell biological and translational discoveries, with the potential for widespread adoption in biomedical research.

22 November 2024 in Nature Biotechnology
Verified
Journal Article
Closed access
PDF file
HKHyejin Kim
Hyejin Kim
RZRyan Zenhausern
Ryan Zenhausern
KGKara Gentry
Kara Gentry
LLLiming Lian
Liming Lian
SHSebastian G. Huayamares
Sebastian G. Huayamares
JDJames E. Dahlman
James E. Dahlman

3 October 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
KHKeyi Han
Keyi Han
XHXuanwen Hua
Xuanwen Hua
VVVishwa Vasani
Vishwa Vasani
GKGe-Ah R. Kim
Ge-Ah R. Kim
WLWenhao Liu
Wenhao Liu
SJShu Jia
Shu Jia
Live-cell imaging reveals the phenotypes and mechanisms of cellular function and their dysfunction that underscore cell physiology, development, and pathology. Here, we report a 3D super-resolution live-cell microscopy method by integrating radiality analysis and Fourier light-field microscopy (rad-FLFM). We demonstrated the method using various live-cell specimens, including actins in Hela cells, microtubules in mammary organoid cells, and peroxisomes in COS-7 cells. Compared with conventional wide-field microscopy, rad-FLFM realizes scanning-free, volumetric 3D live-cell imaging with sub-diffraction-limited resolution of ∼150 nm (x-y) and 300 nm (z), milliseconds volume acquisition time, six-fold extended depth of focus of ∼6 µm, and low photodamage. The method provides a promising avenue to explore spatiotemporal-challenging subcellular processes in a wide range of cell biological research.

27 July 2024 in Composites Science and Technology
Verified
Journal Article
Closed access
ZLZihao Lin
Zihao Lin
JLJiaxiong Li
Jiaxiong Li
ZSZhijian Sun
Zhijian Sun
AFAndrew D. Fang
Andrew D. Fang
KHKeyi Han
Keyi Han
CWChing-Ping Wong
Ching-Ping Wong

24 July 2023 in ACS Photonics
Verified
Journal Article
Open access
KYKyungduck Yoon
Kyungduck Yoon
KHKeyi Han
Keyi Han
KTKidan Tadesse
Kidan Tadesse
BMBiagio Mandracchia
Biagio Mandracchia
SJShu Jia
Shu Jia
Super-resolution fluorescence microscopy has revolutionized cell biology over the past decade, enabling the visualization of subcellular complexity with unparalleled clarity and detail. However, the rapid development of image-scanning-based super-resolution systems still restrains convenient access to commonly used instruments such as epi-fluorescence microscopes. Here, we present multifocal scanning microscopy (MSM) for super-resolution imaging with simultaneous multicolor acquisition and minimal instrumental complexity. MSM implements a stationary, interposed multifocal multicolor excitation by exploiting the motion of the specimens, realizing super-resolution microscopy through a general epi-fluorescence platform without compromising the image-scanning mechanism or inducing complex instrument alignment. The system is demonstrated with various phantom and biological specimens, and the results present effective resolution doubling, optical sectioning, and contrast enhancement. We anticipate MSM, as a highly accessible and compatible super-resolution technique, to offer a promising methodological pathway for broad cell biological discoveries.