Shangtao Hu

Shangtao Hu

Auto-generated profile, based on publicly available information

Shangtao Hu

Central South University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2023 in Structures
Verified
Journal Article
Closed access
SHShangtao Hu
Shangtao Hu
MYMenggang Yang
Menggang Yang
DMDongliang Meng
Dongliang Meng
RHRenkang Hu
Renkang Hu

15 November 2024 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
SHShangtao Hu
Shangtao Hu
HHHong Hao
Hong Hao
DMDongliang Meng
Dongliang Meng
MYMenggang Yang
Menggang Yang

17 May 2022 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
SHShangtao Hu
Shangtao Hu
DMDongliang Meng
Dongliang Meng
RHRenkang Hu
Renkang Hu
MYMenggang Yang
Menggang Yang
To mitigate longitudinal vibration of long-span railway suspension bridges, a Combined Viscous-Steel Damping System (CVSDS) is put forward in this paper. In the CVSDS, the viscous damper is expected to work under train braking and frequent earthquakes, while the steel damper can resist rare earthquakes. Moreover, a fuse-lock device is proposed to work as the switch between the aforementioned two dampers. The working mechanism of the CVSDS was introduced. The locking function was verified by static test, and the vibration reduction efficiency of the proposed system was validated through numerical method. The results show that the combined system is efficient.

15 November 2023 in Journal of Vibration and Control
Verified
Journal Article
Closed access
SHShangtao Hu
Shangtao Hu
RHRenkang Hu
Renkang Hu
MYMenggang Yang
Menggang Yang
DMDongliang Meng
Dongliang Meng
AIAkira Igarashi
Akira Igarashi
As a typical passive energy dissipation device, the fluid viscous damper (FVD) is widely utilized for structural vibration control. However, performance degradation in FVDs has been highlighted, particularly concerning the gap effect resulting from the imperfect installation and insufficient fluid. This study proposes three analytical models to characterize the gap property in the hysteresis behavior of FVDs, including the Gap model (G. model), the Equivalence model (E. model), and the Stiffness Degradation model (S. model). The purpose of the G. model is to reproduce the zero-force platform in the hysteresis curve. The E. model and S. model are both simplified models, aiming to consider the gap effect by altering the damping coefficient, velocity exponent, and stiffness based on the energy and maximum force equivalence principles. Shake table tests of a single-degree-of-freedom system are carried out to validate and assess the effectiveness and accuracy of these three methods. The results indicate that the gap effect will significantly degrade the vibration mitigation performance of FVDs, and hence it needs to be considered in simulations. The displacement and force obtained using the G. model under distinct loads highly correspond to the experimental results. By adopting the simplified models, satisfactory results can be derived with a lower implementation cost. Among them, the E. model is more appropriate when subjected to harmonic loads, while the S. model is suggested for cases under seismic excitations.

1 July 2023 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
SHShangtao Hu
Shangtao Hu
RHRenkang Hu
Renkang Hu
MYMenggang Yang
Menggang Yang
TWTao Wang
Tao Wang

1 October 2022 in Journal of Vibration and Control
Verified
Journal Article
Closed access
SHShangtao Hu
Shangtao Hu
RHRenkang Hu
Renkang Hu
MYMenggang Yang
Menggang Yang
TWTao Wang
Tao Wang
The combined viscous-steel damping system is a passive energy dissipation device consisting of a fluid viscous damper and a steel yielding damper in series. However, many viscous dampers installed in structures have been suffering from severe oil leakage. This study aims to assess the influence of the leaked viscous damper on the seismic performance of the combined system. Cyclic tests were conducted on the viscous damper with different leakage levels to obtain its degraded hysteretic performance. The modeling method of the leaked viscous damper was proposed according to the experimental result. The locking behavior and seismic mitigation effectiveness of the combined system suffering from oil leakage were investigated based on a single-degree-of-freedom system. The result reveals that ( i) The leaked viscous damper cannot generate damping force at the beginning of the reverse movement of its piston, which is reflected in the hysteretic curves as a “gap” phenomenon. ( ii) The proposed modeling method can accurately simulate the damping characteristics of the leaked viscous damper. ( iii) In spite of the leakage severity, the combined system possesses reliable locking behavior and decent vibration mitigation effectiveness under earthquakes. ( iv) The combined system is superior to the viscous damper in mitigating seismic-induced displacement when suffering from oil leakage.