Department of Bioengineering, University of Pittsburgh, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MFMark Freithaler
Mark Freithaler
ACAnand Chandrasekhar
Anand Chandrasekhar
VDVishaal Dhamotharan
Vishaal Dhamotharan
CLCederick Landry
Cederick Landry
SSSanjeev G. Shroff
Sanjeev G. Shroff
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
Objective: Oscillometric finger pressing is a potential method for absolute blood pressure (BP) monitoring via a smartphone. The user presses their fingertip against a photoplethysmography-force sensor unit on a smartphone to steadily increase the external pressure on the underlying artery. Meanwhile, the phone guides the finger pressing and computes systolic BP (SP) and diastolic BP (DP) from the measured blood volume oscillations and finger pressure. The objective was to develop and evaluate reliable finger oscillometric BP computation algorithms. Methods: The collapsibility of thin finger arteries was exploited in an oscillometric model to develop simple algorithms for computing BP from the finger pressing measurements. These algorithms extract features from “width” oscillograms (oscillation width versus finger pressure functions) and the conventional “height” oscillogram for markers of DP and SP. Finger pressing measurements were obtained using a custom system along with reference arm cuff BP measurements from 22 subjects. Measurements were also obtained during BP interventions in some subjects for 34 total measurements. Results: An algorithm employing the average of width and height oscillogram features predicted DP with correlation of 0.86 and precision error of 8.6 mmHg with respect to the reference measurements. Analysis of arm oscillometric cuff pressure waveforms from an existing patient database provided evidence that the width oscillogram features are better suited to finger oscillometry. Conclusion: Analysis of oscillation width variations during finger pressing can improve DP computation. Significance: The study findings may help in converting widely available devices into truly cuffless BP monitors for improving hypertension awareness and control.

16 April 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CLCederick Landry
Cederick Landry
MFMark Freithaler
Mark Freithaler
VDVishaal Dhamotharan
Vishaal Dhamotharan
HDHadi Daher
Hadi Daher
SSSanjeev G. Shroff
Sanjeev G. Shroff
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
Objective: Oscillometric finger pressing is a smartphone-based blood pressure (BP) monitoring method. Finger photoplethysmography (PPG) oscillations and pressure are measured during a steady increase in finger pressure, and an algorithm computes systolic BP (SP) and diastolic BP (DP) from the measurements. The objective was to assess the impact of finger artery viscoelasticity on the BP computation. Methods: Nonlinear viscoelastic models relating transmural pressure (finger BP – applied pressure) to PPG oscillations during finger pressing were developed. The output of each model to a measured transmural pressure input was fitted to measured PPG oscillations from 15 participants. A parametric sensitivity analysis was performed via model simulations to elucidate the viscoelastic effect on the derivative-based BP computation algorithm. Results: A Wiener viscoelastic model comprising a first-order transfer function followed by a static sigmoidal function fitted the measured PPG oscillations better than an elastic model containing only the static function (median (IQR) error of 30.5% (25.6%–34.0%) vs 50.9% (46.7%–53.7%); p<0.01). In Wiener model simulations, the derivative algorithm underestimated SP, especially with high pulse pressure and low transfer function cutoff frequency (i.e., greater viscoelasticity). The mean of the normalized PPG waveform at the maximum oscillation beat was found to correlate with the cutoff frequency ( r = −0.8) and could thus possibly be used to compensate for viscoelasticity. Conclusion: Finger artery viscoelasticity negatively impacts oscillometric BP computation algorithms but can potentially be compensated for using available measurements. Significance: These findings may help in converting smartphones into truly cuffless BP monitors for improving hypertension awareness and control.

1 July 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MFMark Freithaler
Mark Freithaler
HDHadi Daher
Hadi Daher
CLCederick Landry
Cederick Landry
VDVishaal Dhamotharan
Vishaal Dhamotharan
SWShipeng Wang
Shipeng Wang
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
Objective: Oscillometric finger pressing is a potential method for smartphone-based blood pressure (BP) monitoring. A photoplethysmography (PPG)-force sensor unit measures the slowly increasing finger pressure applied by the user under visual guidance and the resulting variable blood volume oscillations (“AC PPG”). BP can then be estimated from the oscillation height versus finger pressure function. The non-oscillating component of PPG (“DC PPG”) during oscillometric finger pressing was investigated. Methods: The total (AC+DC) PPG waveform, finger pressure, and ECG waveform during finger pressing were measured with a modified custom system along with arm cuff BP in volunteers. A mathematical model accounting for the arterial compliance curve and tissue compression was developed to explain the measured total PPG waveform versus finger pressure function. The model predicted that DC PPG (average of the total PPG over each heartbeat) versus finger pressure function will show a fiducial marker (bend) near finger systolic BP (SP). An algorithm was developed to detect this bend and estimate arm SP from the finger pressing measurements. Results: The model explained the measured total PPG waveform versus finger pressure function over the finger pressure range that is relevant to BP estimation. The model-based algorithm yielded a correlation coefficient of 0.90 and a precision error of 9.2 mmHg against cuff SP (N = 18). Conclusion: An easy-to-understand model can explain the total PPG waveform during finger pressing, and SP can be estimated from the DC (non-oscillating) PPG versus finger pressure function. Significance: These findings may prove useful in converting ubiquitous smartphones into BP sensors.