Polina S. Druzhinina

Polina S. Druzhinina

Auto-generated profile, based on publicly available information

Polina S. Druzhinina

Saint Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance of Consumer Rights Protection and Human Wellbeing

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2023 in Digital Diagnostics
Verified
Journal Article
Open access
PDF file
AVAleksandr V. Vodovatov
Aleksandr V. Vodovatov
OGOlga A. Golchenko
Olga A. Golchenko
IMIrina A. Mashchenko
Irina A. Mashchenko
DADarya V. Alekseeva
Darya V. Alekseeva
LCLarisa A. Chipiga
Larisa A. Chipiga
ISIlia V. Soldatov
Ilia V. Soldatov
BACKGROUND: Currently, no systematic data are available on fetal radiation exposure as a result of radiographic studies during pregnancy. Consequently, there are no approved methods of its calculation that can be used in clinical practice. It is especially relevant for computed tomography scans as it is a widely used and highly informative method of diagnostic imaging associated with high exposure levels. AIM: to systematize currently available data on radiation dose absorbed by the fetus from computed tomography scans in pregnant women. MATERIALS AND METHODS: The search for publications in Russian and English was conducted in PubMed/Medline, Google Scholar and еLibrary. The final analysis included 12 papers including 8 studies using human body phantoms, 3 retrospective studies and one prospective clinical study. RESULTS: Abdominal and pelvic computed tomography scans as well as whole-body scans were found to be associated with the highest fetal radiation exposure. However, in none of the publications the fetal exposure limit was exceeded. CONCLUSION: Clinically indicated non-contrast-enhanced computed tomography scans in pregnant women are not likely to be associated with the fetal absorbed doses that exceed the limit of 100 mGy regardless of the scanned area. However, this limit might be exceeded in case of performing multiple studies or if multiphase abdominal or pelvic computed tomography scans, or whole-body computed tomography scans are performed in patients with multiple trauma. In these cases, a decision regarding the need for these investigations should be made by a multi-disciplinary team (including radiation safety specialists, diagnostic radiologists and clinicians) based on the results of additional risk assessment.

7 October 2024 in Radiatsionnaya Gygiena = Radiation Hygiene
Verified
Journal Article
Open access
PDF file
YDYu. V. Druzhinina
Yu. V. Druzhinina
ZLZ. A. Lantukh
Z. A. Lantukh
KTK. V. Tolkachev
K. V. Tolkachev
ISI. V. Soldatov
I. V. Soldatov
MSM. P. Shatenok
M. P. Shatenok
SRS. A. Ryzhov
S. A. Ryzhov
Diagnostic reference levels are one of the effective tools for optimizing patient radiation doses in diagnostic radiology. The staff of domestic radiology departments does not have an understanding of the development process and use of diagnostic reference levels during X-ray examinations, although this tool is a generally accepted in practice abroad. The article shows the experience of forming regional diagnostic reference levels based on measurements provided by the accredited testing laboratory of the Scientific and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Healthcare Department. The diagnostic reference levels for radiography in Moscow were developed for eight of the most common types of examinations based on the operation of 216 digital X-ray machines. The resulting levels, expressed in the dose-area product (cGy-cm2) and effective dose (mSv), were compared with the local diagnostic reference levels for the Ryazan region, Russia, and national diagnostic reference levels for other countries. The analysis showed continuity in the values. Some types of studies have been optimized. The developed diagnostic reference levels are the quality performance indicators foe diagnostic radiology departments and will be used to optimize a patient radiation dose during diagnostic studies in Moscow.

13 January 2025 in Radiatsionnaya Gygiena = Radiation Hygiene
Verified
Journal Article
Open access
PDF file
PDP. S. Druzhinina
P. S. Druzhinina
LCL. A. Chipiga
L. A. Chipiga
AVA. V. Vodovatov
A. V. Vodovatov
ISI. V. Soldatov
I. V. Soldatov
ZLZ. A. Lantukh
Z. A. Lantukh
KTK. V. Tolkachev
K. V. Tolkachev
Today in the Russian Federation, the existing method for assessing patients` effective doses during computed tomography in the form of conversion coefficients from the dose-length product provides for the area from the head to the upper third of the femur but does not consider the possibility of scanning the whole body including the lower extremities. In this case, for some nosologies, the lower extremities may be involved. The aim of the study was to develop conversion coefficients from the dose-length product to the effective dose for whole-body computed tomography scanning including the patient's lower extremities. The coefficients for whole-body computed tomography scans (including the lower extremities) were determined for a sample of computed tomography scanners that are part of positron emission tomography combined with computed tomography devices of different models for adults and children of different age groups. In NCICT 3.0 software absorbed organ doses were calculated taking into account the specific model of devices and scan length. Effective doses were determined in accordance with the methodology presented in Publication 60 of the International Commission on Radiological Protection and Radiation Safety Standards 99/2009. Separately, conversion coefficients were developed from the dose-length product to the absorbed dose in uterus to enable predictive assessment of doses in the fetus in pregnant women. The study presents the average values of the received effective doses, absorbed doses in uterus and conversion coefficients for all considered models of devices. Conversion coefficients for protocols with automatic tube current modulation were lower compared to those for protocols without automatic tube current modulation, especially for pediatric patients: for children with an average age of 0 years – 9 times, for children an average age of 1 year – 6 times, for children an average age of 5 years – 5 times, for children an average age of 10 years – 3 times, for children an average age of 15 years – 2 times; for adults the difference was 20%. Comparison of the conversion coefficients from the dose-length product to the effective dose for computed tomographic scanning of the whole body area limited to the upper third of the femur, presented in guidelines 2.6.1.3584-19, with the values obtained in this study for the whole body area with the lower extremities without automatic tube current modulation showed that for all age groups, with the exception of newborns, the conversion coefficients for the scanning area with the lower extremities are lower than those presented in the guidelines. Using the conversion coefficients from the Guideline 2.6.1.3584-19 for whole-body computed tomography scanning with the lower extremities will lead to a significant overestimation of patient doses. The calculated conversion coefficients from the dose-length product to the absorbed dose in uterus and from the dose-length product to the effective dose for computed tomography examination of the whole body with the lower extremities for different age groups of patients are suitable for assessing the effective doses of patients and for prognostic estimates of absorbed dose in the fetus in pregnant women.

26 September 2023 in Digital Diagnostics
Verified
Journal Article
Open access
PDF file
AVAleksandr V. Vodovatov
Aleksandr V. Vodovatov
LCLarisa A. Chipiga
Larisa A. Chipiga
PDPolina S. Druzhinina
Polina S. Druzhinina
ISIlya G. Shatskiy
Ilya G. Shatskiy
APAnastasiya V. Petryakova
Anastasiya V. Petryakova
ЛАЛантух Зоя Александровна
Лантух Зоя Александровна
The form of federal governmental statistical surveillance № 3-DOZ, titled Data on patient doses from medical X-ray examinations, has changed significantly by the order of Rosstat N 880. In particular, the structure of the forms has been revised: studies involving high doses were dedicated from the rest; the section on radionuclide diagnostics has been redesigned; the information on the levels of patient exposure when using individual radionuclides and in hybrid studies have been displayed; information on the number of radiological studies and collective doses for pediatric patients have been introduced; and the number of studies for which typical (average) effective doses of patients are presented has been reduced. The structure of the updated form № 3-DOZ is presented within the framework of this work. In this article, recommendations for filling out № 3-DOZ have been developed in order to increase the reliability of the data provided and reduce the number of procedural errors. This work is a continuation of the article Vodovatov A.V., Chipiga L.A., Bratilova A.A., Druzhinina P.S., Shatskiy I.G., Petryakova A.V., Sarycheva S.S., Biblin A.M., Akhmatdinov R.R., Kapyrina Yu.N., Soldatov I.V., Puzyrev V.G., and Ryzhov S.A. Update of the federal governmental statistical surveillance form № 3-DOZ Data on patient doses from medical X-ray examinations. Perquisites for the update, published in the journal Radiatsionnaya Gygiena (2023. Vol. 16, N 2. P. 126136. DOI: https://doi.org/10.21514/1998-426X-2023-16-2-126-136).

10 October 2025 in Radiatsionnaya Gygiena = Radiation Hygiene
Verified
Journal Article
Open access
PDF file
AVA. V. Vodovatov
A. V. Vodovatov
GGG. A. Gorsky
G. A. Gorsky
LCL. A. Chipiga
L. A. Chipiga
ALA. V. Likhacheva
A. V. Likhacheva
ISI. G. Shatsky
I. G. Shatsky
NVN. M. Vishnyakova
N. M. Vishnyakova
Starting from September 1, 2025, SanPiN 2.6.4115-25 came into force. This is a comprehensive document that establishes requirements for ensuring radiation safety when working with a specific list of ionizing radiation sources, including those used in X-ray diagnostics and therapy. As a result, several regulatory legal acts in the field of radiation safety will be repealed, including SanPiN 2.6.1.1192-03 and SanPiN 2.6.1.2891-11. SanPiN 2.6.4115-25 introduces a number of new as well as revised and updated requirements for ensuring radiation safety in the operation of ionizing radiation-generating equipment used in medical practice. This paper presents analysis of the changes and additions introduced in SanPiN 2.6.4115-25 in comparison with the documents that should be repealed starting from September 1, 2025, which previously regulated radiation safety requirements for X-ray diagnostics and therapy. Conclusion: The work presents the background for revising the sanitary rules and standards and provides recommendations for improving the regulation of radiation protection in medical exposure.

1 April 2026 in Radiatsionnaya Gygiena = Radiation Hygiene
Verified
Journal Article
Closed access
ISI. G. Shatsky
I. G. Shatsky
PDP. S. Druzhinina
P. S. Druzhinina
LCL. A. Chipiga
L. A. Chipiga
DAD. V. Alekseeva
D. V. Alekseeva
The relevance of this study lies in the need to reconsider established approaches to the use of personal protective equipment in computed tomography due to the widespread implementation of automatic tube current and voltage modulation algorithms. Since PPE can distort the input data for these algorithms, their use may not only fail to reduce but could also unjustifiably increase the patient's radiation dose, which requires detailed experimental verification, especially in pediatric practice where patients are most sensitive to ionizing radiation. The aim of this work is to assess the influence of personal protective equipment on the performance of the automatic tube current and voltage modulation programs (CareDose 4D and Care kV) during CT examinations on a Somatom Force (Siemens) scanner, using an anthropomorphic phantom of a five-year-old child. Materials and Methods : The study was conducted at the CT department of the Almazov National Medical Research Centre using an anthropomorphic phantom of a five-year-old child and a technically sound Somatom Force (Siemens) tomograph. To assess the impact of personal protective equipment on the operation of the automatic current and voltage modulation programs (CareDose 4D and Care kV), a series of phantom scans was performed with and without various positioning options for a protective lead apron, simulating real clinical practice. Results and Discussion : The results showed that when a lead apron enters the topogram area, the system interprets this as an increase in the patient's body size and density, which automatically increases the radiation parameters compared to a scan performed without the lead apron. Conclusion: Evaluating the impact of this effect on absorbed and effective doses requires further research to determine the appropriateness of using personal protective equipment in computed tomography.