1 September 2005 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
This paper presents two robot devices for use in the rehabilitation of upper limb movements and reports the quantitative parameters obtained to characterize the rate of improvement, thus allowing a precise monitoring of patient's recovery. A one degree of freedom (DoF) wrist manipulator and a two-DoF elbow-shoulder manipulator were designed using an admittance control strategy; if the patient could not move the handle, the devices completed the motor task. Two groups of chronic post-stroke patients (G1 n = 7, and G2 n = 9) were enrolled in a three week rehabilitation program including standard physical therapy (45 min daily) plus treatment by means of robot devices, respectively, for wrist and elbow-shoulder movements (40 min, twice daily). Both groups were evaluated by means of standard clinical assessment scales and a new robot measured evaluation metrics that included an active movement index quantifying the patient's ability to execute the assigned motor task without robot assistance, the mean velocity, and a movement accuracy index measuring the distance of the executed path from the theoretic one. After treatment, both groups improved their motor deficit and disability. In G1, there was a significant change in the clinical scale values (p < 0.05) and range of motion wrist extension (p < 0.02). G2 showed a significant change in clinical scales (p < 0.01), in strength (p < 0.05) and in the robot measured parameters (p < 0.01). The relationship between robot measured parameters and the clinical assessment scales showed a moderate and significant correlation (r > 0.53 p < 0.03). Our findings suggest that robot-aided neurorehabilitation may improve the motor outcome and disability of chronic post-stroke patients. The new robot measured parameters may provide useful information about the course of treatment and its effectiveness at discharge.
19 February 2007 in Journal of NeuroEngineering and Rehabilitation
Motivation is an important factor in rehabilitation and frequently used as a determinant of rehabilitation outcome. Several factors can influence patient motivation and so improve exercise adherence. This paper presents the design of two robot devices for use in the rehabilitation of upper limb movements, that can motivate patients during the execution of the assigned motor tasks by enhancing the gaming aspects of rehabilitation. In addition, a regular review of the obtained performance can reinforce in patients' minds the importance of exercising and encourage them to continue, so improving their motivation and consequently adherence to the program. In view of this, we also developed an evaluation metric that could characterize the rate of improvement and quantify the changes in the obtained performance. Two groups (G1, n = 8 and G2, n = 12) of patients with chronic stroke were enrolled in a 3-week rehabilitation program including standard physical therapy (45 min. daily) plus treatment by means of robot devices (40 min., twice daily) respectively for wrist (G1) and elbow-shoulder movements (G2). Both groups were evaluated by means of standard clinical assessment scales and the new robot measured evaluation metric. Patients' motivation was assessed in 9/12 G2 patients by means of the Intrinsic Motivation Inventory (IMI) questionnaire. Both groups reduced their motor deficit and showed a significant improvement in clinical scales and the robot measured parameters. The IMI assessed in G2 patients showed high scores for interest, usefulness and importance subscales and low values for tension and pain subscales. Thanks to the design features of the two robot devices the therapist could easily adapt training to the individual by selecting different difficulty levels of the motor task tailored to each patient's disability. The gaming aspects incorporated in the two rehabilitation robots helped maintain patients' interest high during execution of the assigned tasks by providing feedback on performance. The evaluation metric gave a precise measure of patients' performance and thus provides a tool to help therapists promote patient motivation and hence adherence to the training program.
4 April 2007 in Neurorehabilitation and Neural Repair
Objective. The present study aimed to qualify and quantify the different components of motor recovery in a group of stroke patients treated by robot-aided techniques. In addition, the learning model of each motor recovery component was analyzed. Methods . Two groups of poststroke patients were treated with the use of an elbow-shoulder manipulator, respectively, within (recent) and after (chronic) the first 6 months of their cerebrovascular accident. Both groups were evaluated by means of standard clinical assessment scales and a robot-measured evaluation method. Results. These findings confirm that motor training consisting of voluntary movements assisted by the robot device led to significant improvements in motor performance in terms of the kinematic and dynamic components of the arm movements. This corresponded to improvement of impairment as confirmed by the clinical scale results. Conclusions. Knowledge of the recovery components and of the associated performance acquisition model may be useful in assessing and training stroke patients and should make it possible to precisely plan and, if necessary, modify the rehabilitation strategies.
1 December 2005 in Autonomous Robots
18 May 2012 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In robot-assisted neurorehabilitation, matching the task difficulty level to the patient's needs and abilities, both initially and as the relearning process progresses, can enhance the effectiveness of training and improve patients' motivation and outcome. This study presents a Progressive Task Regulation algorithm implemented in a robot for upper limb rehabilitation. It evaluates the patient's performance during training through the computation of robot-measured parameters, and automatically changes the features of the reaching movements, adapting the difficulty level of the motor task to the patient's abilities. In particular, it can select different types of assistance (time-triggered, activity-triggered, and negative assistance) and implement varied therapy practice to promote generalization processes. The algorithm was tuned by assessing the performance data obtained in 22 chronic stroke patients who underwent robotic rehabilitation, in which the difficulty level of the task was manually adjusted by the therapist. Thus, we could verify the patient's recovery strategies and implement task transition rules to match both the patient's and therapist's behavior. In addition, the algorithm was tested in a sample of five chronic stroke patients. The findings show good agreement with the therapist decisions so indicating that it could be useful for the implementation of training protocols allowing individualized and gradual treatment of upper limb disabilities in patients after stroke. The application of this algorithm during robot-assisted therapy should allow an easier management of the different motor tasks administered during training, thereby facilitating the therapist's activity in the treatment of different pathologic conditions of the neuromuscular system.
7 August 2009 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
The aim of this study was to describe in detail a new method, called normalized force control parameter (nFCP), to measure changes in movement dynamics obtained during robot-aided neurorehabilitation, and to evaluate its ability to estimate the clinical scales. The study was conducted in a group of 18 subjects after chronic stroke who underwent robot therapy of the upper limb. We used two different measures of movement dynamics to assess patients' performance during each session of training: the nFCP and force directional error (FDE), both measuring the directional error of the patient-exerted force applied to the end-effector of the robot device. Both metrics exhibited significant changes over the three-week course of treatment. The comparison between nFCP and FDE slopes showed a significant and high correlation (r = 0.79; p < 0.001), indicating that the two parameters are closely correlated. The FDE informed on the direction of the force error, while the nFCP showed a better performance in predicting the clinical scale values. Assessment of the time course of recovery showed that nFCP, FDE and the movement smoothness improved quickly at first and then plateaued, while steady gains in mean velocity of movement took place over a longer time course. These data may be helpful to the therapist in developing more effective robot-based therapy protocols.