Damián Martínez

Damián Martínez

Auto-generated profile, based on publicly available information

Damián Martínez

Laboratorio Nacional de Microscopía Avanzada, Instituto de Biotecnología, Universidad Nacional Autónoma de México

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
ETEsley Torres-García
Esley Torres-García
RPRaúl Pinto-Cámara
Raúl Pinto-Cámara
ALAlejandro Linares
Alejandro Linares
DMDamián Martínez
Damián Martínez
VAVíctor Abonza
Víctor Abonza
AGAdán Guerrero
Adán Guerrero
The resolution of fluorescence microscopy images is limited by the physical properties of light. In the last decade, numerous super-resolution microscopy (SRM) approaches have been proposed to deal with such hindrance. Here we present Mean-Shift Super Resolution (MSSR), a new SRM algorithm based on the Mean Shift theory, which extends spatial resolution of single fluorescence images beyond the diffraction limit of light. MSSR works on low and high fluorophore densities, is not limited by the architecture of the optical setup and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image stacks, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other SRM approaches. Along with its wide accessibility, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.

18 October 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
EGEsley Torres García
Esley Torres García
RCRaúl Pinto Cámara
Raúl Pinto Cámara
ALAlejandro Linares
Alejandro Linares
DMDamián Martínez
Damián Martínez
VAVíctor Abonza
Víctor Abonza
AGAdán Guerrero
Adán Guerrero
Mean-Shift Super Resolution (MSSR) is a principle based on the Mean Shift theory that extends spatial resolution in fluorescence images, beyond the diffraction limit. MSSR works on low- and high-density fluorophore images, is not limited by the architecture of the detector (EM-CCD, sCMOS, or photomultiplier-based laser scanning systems) and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image series, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other analytical super resolution image approaches. Altogether, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.

29 October 2021 in Research Square
Verified
Preprint
Open access
PDF file
EGEsley García
Esley García
RCRaúl Cámara
Raúl Cámara
ALAlejandro Linares
Alejandro Linares
DMDamián Martínez
Damián Martínez
VAVíctor Abonza
Víctor Abonza
AGAdán Guerrero
Adán Guerrero
Mean-Shift Super Resolution (MSSR) is a principle based on the Mean Shift theory that improves the spatial resolution in fluorescence images beyond the diffraction limit. MSSR works on low- and high-density fluorophore images, is not limited by the architecture of the detector (EM-CCD, sCMOS, or photomultiplier-based laser scanning systems) and is applicable to single images as well as temporal series. The theoretical limit of spatial resolution, based on optimized real-world imaging conditions and analysis of temporal image series, has been measured to be 40 nm. Furthermore, MSSR has denoising capabilities that outperform other analytical super resolution image approaches. Altogether, MSSR is a powerful, flexible, and generic tool for multidimensional and live cell imaging applications.

6 May 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
AAAlma Alva
Alma Alva
EBEduardo Brito-Alarcón
Eduardo Brito-Alarcón
ALAlejandro Linares
Alejandro Linares
ETEsley Torres-García
Esley Torres-García
HHHaydeé O. Hernández
Haydeé O. Hernández
AGAdán Guerrero
Adán Guerrero
Due to the wave nature of light, optical microscopy has a lower-bound lateral resolution limit of about half of the wavelength of the detected light, i.e., within the range of 200 to 300 nm. The Fluorescence Fluctuation based Super Resolution Microscopy (FF-SRM) encompases a collection of image analysis techniques which rely on the statistical processing of temporal variations of fluorescence to reduce the uncertainty about the fluorophore positions within a sample, hence, bringing spatial resolution down to several tens of nm. The FF-SRM is known to be suitable for live-cell imaging due to its compatibility with most fluorescent probes and lower instrumental and experimental requirements, which are mostly camera-based epifluorescence instruments. Each FF-SRM approach has strengths and weaknesses, which depend directly on the underlying statistical principles through which enhanced spatial resolution is achieved. In this review, the basic concepts and principles behind a range of FF-SRM methods published to date are revisited. Their operational parameters are explained and guidance for its selection is provided.

4 June 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
DMDamián Martínez
Damián Martínez
BSBruno M. Saraiva
Bruno M. Saraiva
TSTayla Shakespeare
Tayla Shakespeare
MBMark Bates
Mark Bates
DODylan M. Owen
Dylan M. Owen
Ricardo HenriquesRicardo Henriques
Ricardo Henriques
Determining whether a microscopy experiment can resolve a specific feature of a protein assembly remains difficult because researchers must balance imaging modality, labelling strategy, and probe choice. We present VLab4Mic, a simulation platform that predicts structural resolvability before experiments. Starting from atomic models from the PDB or AlphaFold predictions, VLab4Mic places antibodies, nanobodies, chemical linkers, or fluorescent proteins on epitopes, applies stochastic labelling and steric constraints, and generates virtual samples for widefield, confocal, AiryScan, Stimulated Emission Depletion (STED), and Single-Molecule Localisation Microscopy (SMLM). Comparisons with nuclear pore complex data show realistic agreement across modalities. Case studies show that HIV capsid appearance depends strongly on orientation, and that STED and SMLM distinguish domed from flat clathrin lattices, whereas confocal and AiryScan struggle. VLab4Mic thereby helps researchers predict which biological questions are experimentally tractable with a given imaging configuration before spending time finetuning imaging parameters at the microscope.