22 March 2024 in Case Studies in Thermal Engineering
Phase change material (PCM) has been widely studied for efficient thermal management. This work is the first holistic experimental research on the temperature control performance of PCM-integrated firefighters' gloves. The results showed that the thermal protection time could be extended by 2-5 times in the direct contact to hot object tests and around 1.5 times under the radiant/convective heat source tests when embedding a 1-mm-thick PCM layer in gloves. The PCM of melting point 68°C showed the best thermal protection performance in all test conditions since it had the most efficient phase change function during the heating process. Considering the PCM location effect, the PCM with lower melting point (68°C) showed better performance when located close to external environment (heat source) and the PCM with higher melting point (108°C and 151°C) showed better performance when located close to hand. The optimum PCM thickness would be in the range of 0.5-1.0 mm for both thermal protection improvement and hand dexterity purposes. In addition, the time for continuous temperature rises on the hand surface at post-heat exposure was longer when embedding PCM in firefighters' gloves due to the stored latent heat in PCM.
25 April 2019 in Journal of Occupational and Environmental Hygiene
An ASTM International subcommittee on Respiratory Protection, F23.65 is currently developing a consensus standard for assessing respirator fit capability (RFC) criteria of half-facepiece air-purifying particulate respirators. The objective of this study was to evaluate if the test methods being developed for half-facepiece respirators can reasonably be applied to nonpowered full-facepiece–air-purifying respirators (FF–APR). Benchmark RFC test data were collected for three families of FF–APRs (a one-size-only family, a two-size family, and a three-size family). All respirators were equipped with P100 class particulate filters. Respirators were outfitted with a sampling probe to collect an in-mask particle concentration sample in the breathing zone of the wearer. Each of the six respirator facepieces was tested on the National Institute for Occupational Safety and Health 25-subject Bivariate Panel. The RFC test assessed face seal leakage using a PortaCount fit test. Subjects followed the corresponding Occupational Safety and Health Administration-accepted fit test protocol. Two donnings per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of subjects in the panel achieving acceptable fit on at least one of two donnings) was determined for each respirator family at specified fit factor passing levels of 500, 1,000, and 2,000. As a reasonable expectation based on a previous analysis of alpha and beta fit test errors for various panel sizes, the selected PPR benchmark for our study was >75%. At the fit factor passing level of 500 obtained on at least one of two donnings, the PPRs for three-, two-, and one-size families were 100, 79, and 88%, respectively. As the fit factor passing criterion increased from 500 to 1,000 or 2,000, PPRs followed a decreasing trend. Each of the three tested families of FF–APRs are capable of fitting ≥75% of the intended user population at the 500 fit factor passing level obtained on at least one of two donnings. The methods presented here can be used as a reference for standards development organizations considering developing RFC test requirements.
7 December 2020 in Journal of Occupational and Environmental Hygiene
Powered air-purifying respirators (PAPRs) are worn to protect workers from hazardous respiratory exposures in a wide range of workplaces, including healthcare. However, PAPRs may diminish the ability of wearers to correctly hear words spoken by others, potentially interfering with safe performance of healthcare duties. Accordingly, the impact of PAPRs during healthcare use on speech intelligibility (SI) and consequently on user safety, usability, and patient care is not well studied. The objectives of this study were to (1) determine a listener’s ability to comprehend single-syllable words spoken by a PAPR wearer; (2) determine a PAPR wearer’s ability to intelligibly hear and identify single-syllable words spoken by a PAPR wearer; (3) to assess the variability between speakers, listeners, and PAPR models; (4) to investigate the effects of PAPR design features on SI; and (5) inform a SI requirement for certifying future PAPRs for use in healthcare. This study utilized a Modified Rhyme Test to assess SI for PAPRs. The current National Institute for Occupational Safety and Health (NIOSH) methods for assessing SI are limited to the recently introduced PAPR100 respirator class and the class of respirators claiming chemical, biological, radiological, and nuclear (CBRN) protections. Four NIOSH-approved PAPRs were evaluated using four human subjects. Four experimental conditions were examined:(1) Speaker and Listener with no PAPR; (2) Speaker and Listener both wearing PAPRs; (3) Speaker with a PAPR, Listener without a PAPR; and (4) Speaker without a PAPR, Listener with a PAPR resulted in a total of 144 experiments. Statistical analysis showed that the SI performance ratings were not significantly different among the PAPR models, but experimental conditions had significant impact on SI. The pattern of SI across the conditions of the experiment also showed a significant difference depending on PAPR model. The SI performance rating for all PAPRs could meet the current NIOSH CBRN certification requirement for speech intelligibility.
4 December 2024 in International Journal of Occupational Safety and Ergonomics
Transient three-dimensional (3D) heat and moisture transfer simulations were conducted to analyze the thermal performances of the entire phase change material (PCM) integrated into firefighters' gloves. PCM was broken down into several segments to cover the back and palm of the hand but to avoid finger joints to keep hand functions. Parametric studies were performed to explore the effects of PCM melting temperatures, PCM locations in the glove and PCM layer thicknesses on the overall thermal performance improvement of firefighters' gloves. The study found that PCM segments could extend the time for hand skin surfaces (areas covered or not covered by PCM) to reach second-degree burn injury (60 °C) by 1.5-2 times compared to conventional firefighters' gloves without PCM. Moreover, PCM segments could help mitigate the temperature increase on hand skin and glove surface after fire exposure.
25 June 2021 in Journal of Occupational and Environmental Hygiene
The National Institute for Occupational Safety and Health’s methods and requirements for air-purifying respirator breathing resistance in 42 CFR Part 84 do not include work of breathing. The International Organization for Standardization Technical Committee 94, Subcommittee 15 utilized work of breathing to evaluate airflow resistance for all classes of respiratory protective devices as part of their development of performance standards regarding respiratory protective devices. The objectives of this study were: (1) to evaluate the relationship between the International Organization for Standardization’s work of breathing measurements and the National Institute for Occupational Safety and Health’s breathing resistance test results; (2) to provide scientific bases for standard development organizations to decide if work of breathing should be adopted; and (3) to establish regression equations for manufacturers and test laboratories to estimate work of breathing measurements using breathing resistance data. A total of 43 respirators were tested for work of breathing at minute ventilation rates of 10, 35, 65, 105, and 135 liters per minute. Breathing resistance obtained at a constant flow rate of 85 liters per minute per National Institute of Occupational Safety and Health protocol was correlated to each of the parameters (total work of breathing, inhalation, and exhalation) obtained from the work of breathing tests. The ratio of work of breathing exhalation to work of breathing inhalation for all air-purifying respirators is similar to the ratio of exhalation to inhalation resistance when tested individually. The ratios were about 0.8 for filtering facepiece respirators, 0.5 for half-masks, and 0.25 for full-facepiece respirators. The National Institute for Occupational Safety and Health’s breathing resistance is close to work of breathing’s minute ventilation of 35 liters per minute, which represents the common walking/working pace in most workplaces. The work of breathing and the National Institute of Occupational Safety and Health’s breathing resistance were found to be strongly and positively correlated (r values of 0.7–0.9) at each work rate for inhalation and exhalation. In addition, linear and multiple regression models (R-squared values of 0.5–0.8) were also established to estimate work of breathing using breathing resistance. Work of breathing was correlated higher to breathing resistance for full-facepiece and half-mask elastomeric respirators than filtering facepiece respirators for inhalation. For exhalation, filtering facepiece respirators were correlated much better than full-facepiece and half-mask elastomeric respirators. Therefore, the National Institute for Occupational Safety and Health’s breathing resistance may reasonably be used to predict work of breathing for air-purifying respirators. The results could also be used by manufacturers for product development and evaluation.