Anil Gurgen

Anil Gurgen

Auto-generated profile, based on publicly available information

Anil Gurgen

NIST Center for Neutron Research

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
Martin ŠevečekMartin Ševeček
Martin Ševeček
AGAnil Gurgen
Anil Gurgen
ASArunkumar Seshadri
Arunkumar Seshadri
YCYifeng Che
Yifeng Che
MWMalik Wagih
Malik Wagih
KSKoroush Shirvan
Koroush Shirvan

1 October 2018 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
AGAnil Gurgen
Anil Gurgen
KSKoroush Shirvan
Koroush Shirvan

27 September 2022 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
AGAnil Gurgen
Anil Gurgen
NDNam T. Dinh
Nam T. Dinh

9 September 2022 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
LLLinyu Lin
Linyu Lin
AGAnil Gurgen
Anil Gurgen
NDNam Dinh
Nam Dinh

10 February 2025
Verified
Report
Closed access
AWAbdullah Weiss
Abdullah Weiss
AGAnil Gurgen
Anil Gurgen
EBEvan Bures
Evan Bures
JSJoy Shen
Joy Shen
The NIST Neutron Source (NNS) is the proposed reactor for ensuring continued future availability of neutrons for the United States’ scientific needs. The NNS would allow the aging National Bureau of Standards Reactor (NBSR) at the NIST Center for Neutron Research (NCNR) to be decommissioned without affecting the availability of neutrons in the United States. This work describes preliminary thermal-hydraulics assessments of the preconceptual design of the NNS, and the NNS’s behavior during nominal operating conditions and various accident scenarios. Core-level and system-level analyses are conducted via models using the United States Nuclear Regulatory Commission’s (NRC’s) TRAC/RELAP Advanced Computational Engine (TRACE) code. The TRACE code allows for an adequate understanding of the thermal and hydraulic characteristics of the reactor and its components during various analyzed conditions. Safety analyses revealed that the proposed NNS operation maintains adequate margins to ONB, OFI, and CHF. In addition, accident analyses indicated that NNS remains within the safety criterion of blistering temperature throughout all analyzed conditions. Computational fluid dynamics (CFD) analyses revealed the opportunity for various design optimizations, including the design of the inlet to the reactor, the fuel assemblies, and the outlet to the reactor for improved performance and enhanced safety margins. The analyses in this work serve as a first step toward defining a holistic understanding of the thermal hydraulics in the NNS, and it provides a valuable reference for future design iterations.

10 February 2025
Verified
Report
Closed access
DDDavid J Diamond
David J Diamond
AWAbdullah G Weiss
Abdullah G Weiss
OCOsman S Celikten
Osman S Celikten
JCJeremy C Cook
Jeremy C Cook
DSDagistan Sahin
Dagistan Sahin
JSJoy S Shen
Joy S Shen
A pre-conceptual design has been completed for a NIST Neutron Source (NNS). It would replace the existing facility at the NIST Center for Neutron Research (NCNR) to enable significantly more thermal and cold neutrons to be used in many more experiments than possible currently. The scientific community through several organizations has made recommendations to improve access to neutrons and Congress has requested that a strategic plan for the future of the NCNR be written. This report is in support of that plan. At the heart of the NNS is a 20 MW compact reactor core cooled and moderated by light water. The fuel assemblies use uranium-molybdenum plates and reactivity is controlled with hafnium blades. The core is surrounded by a reflector tank containing heavy water and cold neutron sources (CNSs) which use liquid deuterium. Cold neutron guides extend out from the reflector tank to experimental stations as do thermal neutron beams. The reactor has a 40-day fuel cycle and is cooled with three out of the four pumps that are part of the design. The design has acceptable reactivity feedback from increases in temperature or voiding and is within thermal limits for both normal operation and transients or accidents where the instrumentation and control system protects the reactor. The cold neutrons (wavelengths greater than 4 Å) that this design will deliver have an integral neutron brightness 3.5 times that at the present NCNR facility. For the two CNSs at least 15 kW of cooling would be necessary. Neutron currents at instruments will depend on future guide tube design. However, calculations of neutron currents entering guides from one CNS show that there will be a factor of 10 increase relative to the current NCNR cold source. The number of cold neutron guides from each CNS will increase to 16 whereas the single large CNS at the NCNR currently has 12. A proposed set of instruments for both cold and thermal neutron beams is presented as part of the design.