21 February 2019 in IEEE Transactions on Power Systems
1 May 2021 in IEEE Transactions on Power Systems
For the purpose of considering the spatial-temporal characteristics (STC) of large-scale interconnected power system in the modeling, calculation, and analysis of dynamic frequency response (FR), this paper establishes a two-machine equivalent frequency response (TEFR) model and gets its closed-form solution (CFS), which can be used to analytically analysis and fast calculation. In the modeling, the network structure is idealized through simplified matrix of DC power flow and the system is reduced to a typical two-degree-of-freedom vibration system with viscous damping and excitation forces through breaking closed-loop and variable approximation. After that, modal analysis method is managed to obtain TEFR-CFS which represent the dynamic FR of TEFR model as the superposition of system FR and frequency oscillation. And the influence of parameters on frequency oscillation, such as electrical distance, inertial distribution, initial disturbance power distribution coefficient, etc., are analyzed. Furthermore, the analytical expressions of the key characteristics of dynamic FR, such as the initial decline slope, the nadir and the arrival time of nadir, etc., are derived. Numerical simulation proves that STC has significant influence on FR and can be described by TEFR model, TEFR-CFS and the expressions of its key characteristics with accuracy and efficiency.
27 December 2018 in IEEE Transactions on Power Systems
30 January 2025 in Energy
5 August 2024 in IEEE Access
Frequency spatial distribution characteristics of interconnected power systems are highlighted, resulting in significant regional frequency differences and inter-region tie-line power fluctuations, posing a threat to frequency security operation. For two-region interconnected power systems, analytical expressions for regional frequency and inter-regional tie-line power are derived based on the low-order frequency response model. By dividing the fast-varying part and the slow-varying part of the above analytical expressions, analytical frequency security indicators including nadir value, quasi-steady-state value, maximum rate value of regional frequency, and peak value, quasi-steady-state value of inter-regional tie-line power are derived. By dividing the fast-varying part and slow-varying part of the aforementioned analytical expressions, we further derived analytical frequency security indicators, including nadir value, quasi-steady-state value, maximum rate value of regional frequency, and peak value, quasi-steady-state value of inter-area tie-line power. Through case studies based on the IEEE 2-region 4-machine system, the results indicate that the obtained analytical frequency security indicators can accurately describe the frequency dynamics following a major disturbance for two-region interconnected power systems.