Maryam Zebarjadi

Maryam Zebarjadi

Auto-generated profile, based on publicly available information

Maryam Zebarjadi

Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2024 in IEEE Open Journal of the Computer Society
Verified
Journal Article
Open access
FTFarzam Tajdari
Farzam Tajdari
THToon Huysmans
Toon Huysmans
XYXinhe Yao
Xinhe Yao
JXJun Xu
Jun Xu
MZMaryam Zebarjadi
Maryam Zebarjadi
YSYu (Wolf) Song
Yu (Wolf) Song
4D-scans of dynamic deformable human body parts help researchers have a better understanding of spatiotemporal features. However, reconstructing 4D-scans utilizing multiple asynchronous cameras encounters two main challenges: 1) finding dynamic correspondences among different frames captured by each camera at the timestamps of the camera in terms of dynamic feature recognition, and 2) reconstructing 3D-shapes from the combined point clouds captured by different cameras at asynchronous timestamps in terms of multi-view fusion. Here, we introduce a generic framework able to 1) find and align dynamic features in the 3D-scans captured by each camera using the nonrigid-iterative-closest-farthestpoints algorithm; 2) synchronize scans captured by asynchronous cameras through a novel ADGC-LSTMbased-network capable of aligning 3D-scans captured by different cameras to the timeline of a specific camera; and 3) register a high-quality template to synchronized scans at each timestamp to form a highquality 3D-mesh model using a non-rigid registration method. With a newly developed 4D-foot-scanner, we validate the framework and create the first open-access data-set, namely the 4D-feet. It includes 4Dshapes (15 fps) of the right and left feet of 58 participants (116 feet including 5147 3D-frames), covering significant phases of the gait cycle. The results demonstrate the effectiveness of the proposed framework, especially in synchronizing asynchronous 4D-scans.

15 May 2025 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MZMaryam Zebarjadi
Maryam Zebarjadi
AOAnna J. Organ
Anna J. Organ
DZDaniel P. Zachs
Daniel P. Zachs
HLHubert H. Lim
Hubert H. Lim
Objective: Recent research highlights the potential of ultrasound (US) stimulation as a noninvasive tool for modulating neural and cellular signaling in the spleen and liver to treat inflammatory diseases and diabetes. However, challenges like nerve activation failures, off-target stimulation, and organ motion during respiration can affect treatment efficacy. This study introduces a novel tracking framework for accurate liver and spleen motion tracking using US imaging to overcome these challenges. Methods: The tracking framework integrates an enhanced Kanade–Lucas–Tomasi (EKLT) tracker with a long short-term memory (LSTM) predictor. The EKLT tracker provides precise annotations that improve LSTM training, while the LSTM compensates for occlusions and noise by making predictions based on prior data and dynamically adjusting the region of interest (ROI). Spleen motion tracking was evaluated using 40 recordings from 10 participants, each undergoing four distinct breathing patterns. Additionally, the method was evaluated on a liver motion dataset from MICCAI, collected from 9 subjects. Results: Spleen tracking was most accurate during slow, shallow breathing, with an average error of 0.4 $\pm$ 0.4 mm, and had an average error of 1.37 $\pm$ 0.9 mm during fast, deep breathing. Liver tracking results showed high accuracy with an average error of 0.3 $\pm$ 0.2 mm. Conclusion: The EKLT-LSTM framework offers advantages over previous tracking models, providing high accuracy in tracking liver and spleen motion under occlusion and noisy conditions. Significance: The EKLT-LSTM is suitable for end-organ modulation applications and can be adapted to other ultrasound-guided therapies and bioelectronic medicine.

7 October 2025 in International Journal of Imaging Systems and Technology
Verified
Journal Article
Open access
MZMaryam Zebarjadi
Maryam Zebarjadi
HLHubert H. Lim
Hubert H. Lim
Ultrasound (US) imaging is widely used in image‐guided therapies due to its real‐time capability, high temporal resolution, cost‐effectiveness, safety, and portability. While many US tracking methods exist, most reviews focus on conventional techniques and overlook recent advances in deep learning (DL). Existing DL surveys often emphasize modalities like MRI (Magnetic Resonance Imaging) or CT (Computed Tomography), but US tracking presents unique challenges, such as speckle noise, acoustic shadowing, and occlusions, that require tailored solutions. With increasing interest in automating US‐guided procedures, particularly for respiratory‐induced motion (RIM) tracking, this review fills a gap by focusing on recent DL‐based methods specifically developed for US motion tracking. We conducted a targeted review of state‐of‐the‐art DL techniques, categorizing them by network architecture. Special attention is given to studies using benchmark datasets like CLUST (Challenge on Liver Ultrasound Tracking), which enable standardized performance comparison. DL‐based methods demonstrate improved accuracy and robustness in difficult scenarios, such as out‐of‐plane motion and occlusions, where traditional approaches often underperform. DL has significantly improved the feasibility of markerless US tracking in clinical settings, supporting more automated and reliable image‐guided interventions. While conventional methods still offer value, hybrid strategies that integrate DL with traditional tracking or sensor fusion approaches show strong potential. This review complements prior surveys on conventional US tracking, serving as a useful resource for researchers developing robust, automated US‐based applications.

27 March 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MZMaryam Zebarjadi
Maryam Zebarjadi
AOAnna Organ
Anna Organ
LGLindsey A Grafstrom
Lindsey A Grafstrom
DZDaniel Zachs
Daniel Zachs
HLHubert H Lim
Hubert H Lim
Objective. Ultrasound (US) stimulation of the spleen has shown promise in activating anti-inflammatory neural reflexes for treating conditions such as rheumatoid arthritis and sepsis. However, clinical translation remains challenging due to respiratory-induced motion (RIM), which risks off-target stimulation and often requires manual adjustment. While US imaging offers key advantages, tracking reliability is reduced by acoustic window loss and occlusion. This study introduces a robust tracking framework that enhances US-based motion monitoring via adaptive sensor fusion. Approach. A wearable accelerometer-based motion tracker was developed to monitor spleen displacement during US imaging. The model was trained and calibrated on short segments of tri-axial accelerometry data to estimate organ motion in the US imaging plane. Performance was evaluated within and across sessions and for different sensor placements. The optimal configuration was integrated into an adaptive tracker that automatically switches between image- and sensor based estimates using a frame-wise tracking confidence module, ensuring continuous motion monitoring under loss of the acoustic window. Main Results. The standalone accelerometer model achieved an average error of 2.0 ± 0.8 mm, computed as Euclidean distance to a landmark, across sessions in 27 participants. Under challenging imaging conditions, this model achieved error of 2.3 ± 0.6 mm and the adaptive US-accelerometer tracker significantly improved performance, reducing the error to 0.5 ± 0.1 mm. Significance. A compact, low-cost, body-mounted accelerometer can enhance US-guided therapies by providing robust and continuous motion estimates. The proposed framework is scalable and generalizable to other abdominal targets, supporting autonomous US-based interventions and enables at-home wearable therapeutic applications.

1 October 2025 in Smart Materials and Structures
Verified
Journal Article
Open access
AGAlireza Golgouneh
Alireza Golgouneh
MZMaryam Zebarjadi
Maryam Zebarjadi
BHBrad Holschuh
Brad Holschuh
LDLucy E Dunne
Lucy E Dunne
This study focuses on the force estimation of NiTi shape memory alloy (SMA) actuators, particularly addressing the challenges posed by material fatigue and force degradation over repeated actuation cycles. Traditional modeling approaches for SMAs, which typically include constitutive, phase transformation, and heat transfer sub-models, often fail to account for these degradation phenomena, leading to inaccuracies in long-term predictions. To overcome these limitations, we developed and implemented multivariate long short-term memory (LSTM) recurrent neural networks for accurate force estimation using measured parameters such as electrical power (current, voltage), strain, and temperature. An extensive experimental setup was designed to cyclically and electrothermally (Joule heating) activate the SMA actuators at varying strain levels, and the degradation in force production was quantified, with a reduction of up to 20.62% observed after 1000 cycles. The study introduced both single-stage and two-stage LSTM architectures, with the SLF model, which incorporates historical force data along with other measurements, achieving the highest accuracy (RMSE of 0.003 N). More sensor-limited and deployment-oriented variants also performed well: SLWF and SLWTF achieved RMSEs of 0.089 N and 0.110 N, respectively, and the two-stage MTSL (with learned temperature as a hidden state) achieved 0.096 N. The proposed LSTM-based models demonstrated their efficacy in providing reliable force estimations under conditions of actuator degradation, making them suitable for real-time applications where traditional analytical models fall short. These findings offer valuable insights for applications requiring stabilized forces and consistent actuation performance in the presence of material fatigue.