Michael Bayer

Michael Bayer

Auto-generated profile, based on publicly available information

Michael Bayer

Leibniz-Institut für Bildungsverläufe (LIfBi), Kompetenzen, Persönlichkeit, Lernumwelten

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2025 in Energy
Verified
Journal Article
Open access
MBMichael Bayer
Michael Bayer
CMCurtis Meister
Curtis Meister
PSPhilipp Schuetz
Philipp Schuetz
WVWilly Villasmil
Willy Villasmil
HWHeimo Walter
Heimo Walter
ADAbdulrahman Dahash
Abdulrahman Dahash

1 December 2017 in Berliner Journal für Soziologie
Verified
Journal Article
Closed access
PDF file
ASAndreas Schmitz
Andreas Schmitz
MBMichael Bayer
Michael Bayer

30 November 2016
Verified
Book Chapter
Closed access
PDF file
MBMichael Bayer
Michael Bayer
FWFlorian Wohlkinger
Florian Wohlkinger

9 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MBMichael Bayer
Michael Bayer
ASArtem Sotnikov
Artem Sotnikov
ADAbdulrahman Dahash
Abdulrahman Dahash
HWHeimo Walter
Heimo Walter
WVWilly Villasmil
Willy Villasmil
Large-scale pit thermal energy storage (PTES) is a key enabling technology for flexible district heating and cooling (DHC) systems. Conventional PTES applications typically rely on a single large storage volume operated over a wide temperature range, which limits thermal stratification, complicates operation, and restricts the simultaneous use of the storage for heating and cooling. In chiller-free systems, this constraint also precludes solar thermal integration, as maintaining cooling capability requires low storage temperatures. This study introduces a cascading PTES concept, in which the total storage volume is distributed across multiple units purposely operated at distinct temperature levels. By functionally separating temperature domains, the proposed concept enables the simultaneous provision of heating and cooling and allows solar thermal integration without compromising cooling functionality. The cascading configuration is evaluated using dynamic Modelica/Dymola simulations and compared against a centralized single-PTES base case and bidirectional and reservoir network (BN/RN) benchmarks under identical boundary conditions. Results show that the uninsulated cascade achieves a stratification deviation index (SDI) of 0.13 after 90 days, outperforming even the insulated single-PTES (SDI = 0.23). At system level, the cascading configuration reduces electricity consumption by 46 % compared to the single-PTES base case and achieves a system seasonal performance factor of 5.8, exceeding the BN/RN benchmarks by 5 % while maintaining the advantages of a centralized architecture.