Sophie R. Cook

Sophie R. Cook

Auto-generated profile, based on publicly available information

Sophie R. Cook

Department of Chemistry, University of Washington, Seattle, Washington 98195, United States

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2021 in Annual Review of Biomedical Engineering
Verified
Journal Article
Open access
JHJennifer H. Hammel
Jennifer H. Hammel
SCSophie R. Cook
Sophie R. Cook
MBMaura C. Belanger
Maura C. Belanger
JMJennifer M Munson
Jennifer M Munson
RPRebecca R. Pompano
Rebecca R. Pompano
Modeling immunity in vitro has the potential to be a powerful tool for investigating fundamental biological questions, informing therapeutics and vaccines, and providing new insight into disease progression. There are two major elements to immunity that are necessary to model: primary immune tissues and peripheral tissues with immune components. Here, we systematically review progress made along three strategies to modeling immunity: ex vivo cultures, which preserve native tissue structure; microfluidic devices, which constitute a versatile approach to providing physiologically relevant fluid flow and environmental control; and engineered tissues, which provide precise control of the 3D microenvironment and biophysical cues. While many models focus on disease modeling, more primary immune tissue models are necessary to advance the field. Moving forward, we anticipate that the expansion of patient-specific models may inform why immunity varies from patient to patient and allow for the rapid comprehension and treatment of emerging diseases, such as coronavirus disease 2019.

21 May 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
SCSophie R Cook
Sophie R Cook
ABAlexander G Ball
Alexander G Ball
AMAnwaruddin Mohammad
Anwaruddin Mohammad
RPRebecca R. Pompano
Rebecca R. Pompano
Multi-organ-on-chip systems (MOOCs) have the potential to mimic communication between organ systems and reveal mechanisms of health and disease. However, many existing MOOCs are challenging for non-experts to implement, due to complex tubing, electronics, or pump mechanisms. In addition, few MOOCs have incorporated immune organs such as the lymph node (LN), limiting their applicability to critical events such as vaccination. Here we developed a 3D-printed, user-friendly device and companion tubing-free impeller pump to co-culture two or more tissue samples, including a LN, under a recirculating common media. Native tissue structure and immune function were incorporated by maintaining slices of murine LN tissue ex vivo in 3D-printed mesh supports for at least 24 hr. In a two-compartment model of a LN and an upstream injection site, vaccination of the multi-tissue chip was similar to in vivo vaccination in terms of locations of antigen accumulation and acute changes in activation markers and gene expression in the LN. We anticipate that in the future, this flexible platform will enable models of multi-organ immune responses throughout the body.

1 October 2024 in International Journal of Science Education, Part B
Verified
Journal Article
Closed access
MHMarlit Hayslett
Marlit Hayslett
XZXueying Zhao
Xueying Zhao
SCSophie Cook
Sophie Cook

29 May 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
SCSophie R. Cook
Sophie R. Cook
MAM. Yunos Alizai
M. Yunos Alizai
WTWan-Chen Tu
Wan-Chen Tu
IRIngrid Robertson
Ingrid Robertson
XWXiaofu Wei
Xiaofu Wei
ATAshleigh B. Theberge
Ashleigh B. Theberge
Blood biomarkers are central to monitoring disease progression and evaluating treatment responses, yet traditional venipuncture captures a single physiological snapshot in time and becomes burdensome with repeated sampling. Remote blood self-sampling offers a path toward longitudinal, decentralized monitoring, but maintaining protein integrity from draw to analysis remains a critical challenge. Here, we optimized pre-analytical blood collection and stabilization parameters to maintain protein levels at the time of collection for use with remote sampling technology. First, we optimized blood collection time with Tasso remote self-sampling devices to minimize interference from clotting, finding that a 2.5 min collection time best reduces clot formation while collecting enough blood. Next, we found that Protein Plus, a commercial protein stabilizer, limited hemolysis (a metric for stabilizer efficacy) in venous blood for up to 5 days at 25°C-35°C and for 1 day at 40°C. In addition, we optimized the stabilizer volume and acceptable blood volume range for self-sampling as the stabilizer efficacy is impacted by the stabilizer to blood ratio and collection volume can vary with remote self-sampling devices. Finally, we incubated stabilized blood samples collected via Tasso device at 25°C-35°C for 72 h, mimicking a 2-day shipping period. Using a panel of 21 inflammatory proteins, we found that Protein Plus limited intracellular protein release for various proteins (e.g., VEGF-A, CCL11, and IL-8), inhibited protein degradation for CCL2, and enabled minimal hemolysis. These results support Protein Plus as a viable stabilization strategy for remote blood collection technology targeting longitudinal inflammatory protein monitoring.