Connor H. Ligeikis

Connor H. Ligeikis

Auto-generated profile, based on publicly available information

Connor H. Ligeikis

Department of Mechanical Engineering, Lafayette College, Easton, PA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
PDF file
GAGiuseppe Abbiati
Giuseppe Abbiati
SMStefano Marelli
Stefano Marelli
CLConnor Ligeikis
Connor Ligeikis
RCRichard Christenson
Richard Christenson
BSBozidar Stojadinovic
Bozidar Stojadinovic
Hybrid simulation is a tool for investigating the dynamic response of a structural prototype subjected to realistic loading. Hybrid simulation is conducted using a hybrid model that combines physical and numerical substructures interacting with each other in a feedback loop. As a result, the tested substructure interacts with a realistic assembly subjected to a credible loading scenario. In the current practice, experimental results obtained via hybrid simulation support conceptualization and calibration of computational models for structural analysis. Instead, this paper extends the scope of hybrid simulation in constructing a safe/failure state classifier for the tested substructure by adaptively designing a sequence of parametrized hybrid simulations. Such a classifier is intended to compute the state of any physical-substructure-like component within system-level numerical simulations. It follows that the main contribution of this paper lies in the way experimental results are aggregated and integrated with structural analysis. The proposed procedure is experimentally validated for a three-degrees-of-freedom hybrid model subjected to Euler buckling.

25 September 2023 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
CLConnor H. Ligeikis
Connor H. Ligeikis
JSJeff Scruggs
Jeff Scruggs
We implement a causal model predictive control (MPC) strategy to maximize power generation from a wave energy converter (WEC) system, for which the power take-off (PTO) systems have both hard stroke (i.e., displacement) limits and force ratings. The approach models the WEC dynamics in discrete time, in a manner that exactly preserves energy flow quantities, and assumes a stationary stochastic disturbance model for the incident wave force. The control objective is to maximize the expected power generation in stationarity, while accounting for parasitic losses in the power train. PTO stroke measurements are assumed to be available for real-time feedback, as well as the free surface elevation of the waves at a designated location relative to the WEC, and the open-loop dynamics of the WEC are assumed to be linear and time invariant. Mean-square stability of the MPC algorithm is proven. The methodology is illustrated in a simulation example pertaining to a heaving cylindrical buoy.

6 April 2023 in IEEE Transactions on Automatic Control
Verified
Journal Article
Closed access
CLConnor H. Ligeikis
Connor H. Ligeikis
JSJeff Scruggs
Jeff Scruggs
A control system is called self-powered if the only energy it requires for operation is that which it absorbs from the plant. For a linear feedback law to be feasible for a self-powered control system, its feedback signal must be colocated with the control inputs, and its input-output mapping must satisfy an associated passivity constraint. The imposition of such a feedback law can be viewed equivalently as the imposition of a linear passive shunt admittance at the actuation ports of the plant. In this paper we consider the use of actively-controlled electronics to impose a self-powered linear feedback law. To be feasible, it is insufficient that the imposed admittance be passive, because parasitic losses must additionally be overcome. We derive sufficient feasibility conditions which explicitly account for these losses. In the finite-dimensional, time-invariant case, the feasibility condition distills to a more conservative version of the Positive Real Lemma, which is parametrized by various loss parameters. Three examples are given, in which this condition is used to determine the least-efficient loss parameters necessary to realize a desired feedback law.

26 March 2024 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
CLConnor H. Ligeikis
Connor H. Ligeikis
JSJeff Scruggs
Jeff Scruggs
In vibration energy-harvesting technologies, feedback control is required to maximize the average power generated from stochastic disturbances. In large-scale applications, it is often advantageous to use three-phase conversion technologies for transduction. In such situations, vector control techniques can be used to optimally control the transducer currents in the direct-quadrature reference frame, as dynamic functions of feedback measurements. In this paradigm, converted energy is optimally controlled via the quadrature current. The direct current is only used to maintain control of the quadrature current when the machine’s internal back electromotive force (EMF) exceeds the voltage of the power bus, a technique called field weakening. Due to increased dissipation in the stator coil, the use of field weakening results in a reduction in power conversion, relative to what would theoretically be possible with a larger bus voltage. This overvoltage issue can be alternatively addressed by imposing a competing objective in the optimization of the quadrature current controller such that the frequency and duration of these overvoltage events are reduced. However, this also results in reduced generated power, due to the need to satisfy the competing constraint. This article examines the tradeoff between these two approaches to overvoltage compensation and illustrates a methodology for determining the optimum balance between the two approaches.

13 December 2023
Verified
Conference Paper
Closed access
CLConnor Ligeikis
Connor Ligeikis
JSJeff Scruggs
Jeff Scruggs
Linear-quadratic-Gaussian (LQG) optimal control theory can be used to maximize the average electrical power generated by a vibratory energy harvester subjected to random disturbances. However, feedback controllers designed using the LQG framework often require large peak power flows for their successful implementation, which may be undesirable for several reasons. In this paper, we propose using a risk-sensitive performance measure to synthesize control laws for stochastic vibratory energy harvesters. The proposed methodology is applied in two examples, in which we show how the risk-sensitive parameter can be systematically tuned to maximize power generation and mitigate excessive power flows. The first example involves a simple single-degree-of-freedom oscillator subjected to a bandpass filtered noise excitation, and the second pertains to ocean wave energy harvesting.

31 May 2023
Verified
Conference Paper
Closed access
JSJeff Scruggs
Jeff Scruggs
CLConnor Ligeikis
Connor Ligeikis
A control system is called self-powered if the only energy it requires for operation is that which it absorbs from the plant. For a linear feedback law to be feasible for a self-powered control system, its feedback signal must be colocated with the control inputs, and its input-output mapping must satisfy an associated passivity constraint. In this paper we consider the use of actively-controlled electronics to impose a self-powered linear feedback law. In this case, the feasibility of a linear feedback law must account for parasitic losses in the electronics and energy storage system. For the case in which the feedback law is linear and time-invariant, this paper derives necessary feasibility conditions which explicitly account for these losses. This feasibility condition is then illustrated in a simple example.