1 January 2022 in Journal of Engineering Mechanics
Hybrid simulation is a tool for investigating the dynamic response of a structural prototype subjected to realistic loading. Hybrid simulation is conducted using a hybrid model that combines physical and numerical substructures interacting with each other in a feedback loop. As a result, the tested substructure interacts with a realistic assembly subjected to a credible loading scenario. In the current practice, experimental results obtained via hybrid simulation support conceptualization and calibration of computational models for structural analysis. Instead, this paper extends the scope of hybrid simulation in constructing a safe/failure state classifier for the tested substructure by adaptively designing a sequence of parametrized hybrid simulations. Such a classifier is intended to compute the state of any physical-substructure-like component within system-level numerical simulations. It follows that the main contribution of this paper lies in the way experimental results are aggregated and integrated with structural analysis. The proposed procedure is experimentally validated for a three-degrees-of-freedom hybrid model subjected to Euler buckling.
25 September 2023 in IEEE Transactions on Control Systems Technology
We implement a causal model predictive control (MPC) strategy to maximize power generation from a wave energy converter (WEC) system, for which the power take-off (PTO) systems have both hard stroke (i.e., displacement) limits and force ratings. The approach models the WEC dynamics in discrete time, in a manner that exactly preserves energy flow quantities, and assumes a stationary stochastic disturbance model for the incident wave force. The control objective is to maximize the expected power generation in stationarity, while accounting for parasitic losses in the power train. PTO stroke measurements are assumed to be available for real-time feedback, as well as the free surface elevation of the waves at a designated location relative to the WEC, and the open-loop dynamics of the WEC are assumed to be linear and time invariant. Mean-square stability of the MPC algorithm is proven. The methodology is illustrated in a simulation example pertaining to a heaving cylindrical buoy.
6 April 2023 in IEEE Transactions on Automatic Control
A control system is called self-powered if the only energy it requires for operation is that which it absorbs from the plant. For a linear feedback law to be feasible for a self-powered control system, its feedback signal must be colocated with the control inputs, and its input-output mapping must satisfy an associated passivity constraint. The imposition of such a feedback law can be viewed equivalently as the imposition of a linear passive shunt admittance at the actuation ports of the plant. In this paper we consider the use of actively-controlled electronics to impose a self-powered linear feedback law. To be feasible, it is insufficient that the imposed admittance be passive, because parasitic losses must additionally be overcome. We derive sufficient feasibility conditions which explicitly account for these losses. In the finite-dimensional, time-invariant case, the feasibility condition distills to a more conservative version of the Positive Real Lemma, which is parametrized by various loss parameters. Three examples are given, in which this condition is used to determine the least-efficient loss parameters necessary to realize a desired feedback law.
26 March 2024 in IEEE Transactions on Control Systems Technology
In vibration energy-harvesting technologies, feedback control is required to maximize the average power generated from stochastic disturbances. In large-scale applications, it is often advantageous to use three-phase conversion technologies for transduction. In such situations, vector control techniques can be used to optimally control the transducer currents in the direct-quadrature reference frame, as dynamic functions of feedback measurements. In this paradigm, converted energy is optimally controlled via the quadrature current. The direct current is only used to maintain control of the quadrature current when the machine’s internal back electromotive force (EMF) exceeds the voltage of the power bus, a technique called field weakening. Due to increased dissipation in the stator coil, the use of field weakening results in a reduction in power conversion, relative to what would theoretically be possible with a larger bus voltage. This overvoltage issue can be alternatively addressed by imposing a competing objective in the optimization of the quadrature current controller such that the frequency and duration of these overvoltage events are reduced. However, this also results in reduced generated power, due to the need to satisfy the competing constraint. This article examines the tradeoff between these two approaches to overvoltage compensation and illustrates a methodology for determining the optimum balance between the two approaches.