13 December 2023 in Annals of Oncology
23 May 2015 in European Radiology
W(With Language Review By Europa Donna–The European Breast Cancer Coalition For The European Society Of Breast Imaging (Eusobi)
With Language Review By Europa Donna–The European Breast Cancer Coalition For The European Society Of Breast Imaging (Eusobi)
+18
This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS® categories and further actions after a breast MRI examination are discussed. Breast MRI is a very sensitive modality, significantly improving screening in high-risk women. It also has a role in clinical diagnosis, problem solving, and staging, impacting on patient management. However, it is not a perfect test, and occasionally breast cancers can be missed. Therefore, clinical and other imaging findings (from mammography/ultrasound) should also be considered. Conversely, MRI may detect lesions not visible on other imaging modalities turning out to be benign (false positives). These risks should be discussed with women before a breast MRI is requested/performed. Because breast MRI drawbacks depend upon the indication for the examination, basic information for the most important breast MRI indications is presented. Seventeen notes and five frequently asked questions formulated for use as direct communication to women are provided. The text was reviewed by Europa Donna–The European Breast Cancer Coalition to ensure that it can be easily understood by women undergoing MRI. Key Points • Information on breast MRI concerns advantages/disadvantages and preparation to the examination • Claustrophobia, implantable devices, allergic predisposition, and renal function should be checked • Before menopause, scheduling on day 7–14 of the cycle is preferred • During the examination, it is highly important that the patient keeps still • Availability of prior examinations improves accuracy of breast MRI interpretation
19 September 2013 in European Radiology
28 November 2016 in European Radiology
FSFlorian F. Schmitzberger
+6
1 February 2004 in Radiology
To determine left ventricular (LV) volumetric and functional parameters from retrospectively electrocardiographically gated multi-detector row computed tomography (CT) by using semiautomated analysis software and to correlate results with those of magnetic resonance (MR) imaging. In 30 patients (mean age, 59.2 years +/- 7.1 [SD]) known to have or suspected of having coronary artery disease, four-channel multi-detector row CT was performed with standard technique, and diastolic and systolic image reconstructions were generated. With commercially available analysis software capable of semiautomated contour detection, end diastolic and end systolic LV volumes were determined from short-axis secondary CT reformations. Steady-state free-precession cine MR images were acquired in short-axis orientation within 48 hours and analyzed by using dedicated software. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MR imaging. Mean end diastolic (138.8 mL +/- 31.9) and end systolic (53.9 mL +/- 21.2) LV volumes as determined with CT correlated well with MR imaging measurements (142.0 mL +/- 32.5 [r = 0.93] and 54.9 mL +/- 22.8 [r = 0.94], respectively [P <.001]). LV ejection fraction (61.6% +/- 10.6 for CT vs 62.3% +/- 10.1 for MR imaging; r = 0.89) and stroke volume (84.6 mL +/- 20.9 for CT vs 86.9 mL +/- 21.5 for MR imaging; r = 0.88) also showed good correlation (P <.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.8% for ejection fraction) without systematic errors. In selected patients, semiautomated analysis software enables LV volumetric and functional analysis based on multi-detector row CT data sets, the results of which correlate well with MR imaging findings.
14 June 2012 in Breast Cancer Research
Introduction: The purpose of this study was to compare the diagnostic accuracy of dual-energy contrast-enhanced digital mammography (CEDM) as an adjunct to mammography (MX) ± ultrasonography (US) with the diagnostic accuracy of MX ± US alone. Methods: One hundred ten consenting women with 148 breast lesions (84 malignant, 64 benign) underwent two-view dual-energy CEDM in addition to MX and US using a specially modified digital mammography system (Senographe DS, GE Healthcare). Reference standard was histology for 138 lesions and follow-up for 12 lesions. Six radiologists from 4 institutions interpreted the images using high-resolution softcopy workstations. Confidence of presence (5-point scale), probability of cancer (7-point scale), and BI-RADS scores were evaluated for each finding. Sensitivity, specificity and ROC curve areas were estimated for each reader and overall. Visibility of findings on MX ± CEDM and MX ± US was evaluated with a Likert scale. Results: The average per-lesion sensitivity across all readers was significantly higher for MX ± US ± CEDM than for MX ± US (0.78 vs. 0.71 using BIRADS, p = 0.006). All readers improved their clinical performance and the average area under the ROC curve was significantly superior for MX ± US ± CEDM than for MX ± US ((0.87 vs 0.83, p = 0.045). Finding visibility was similar or better on MX ± CEDM than MX ± US in 80% of cases. Conclusions: Dual-energy contrast-enhanced digital mammography as an adjunct to MX ± US improves diagnostic accuracy compared to MX ± US alone. Addition of iodinated contrast agent to MX facilitates the visualization of breast lesions.