Total Ionizing Dose (TID) effects induced by different photon sources are studied in MOS devices. The Dose Factor (DF), defined as the ratio between dose deposition in dosimeter and actual dose deposition in MOS sensitive oxides, is estimated using Monte-Carlo simulations of energetic photons striking simple device structures. An effective TID approach is proposed to account for both the real ionizing dose depositions in small volumes and the charge yield. This method is applied to a Silicon-On-Insulator (SOI) technology using three photon sources: the usual ARACOR and 60Co sources, which deliver several tens of keV photons and 1.25 MeV photons respectively, and a third facility named ORIATRON, a 6 MeV electron linear accelerator that produces photons on a wide energy spectrum. This topic, investigated intensively in the literature a few decades ago, is revisited in the context of several evolutions including: new radiation sources, novel simulation tools and device scaling which all impact ionizing dose deposition in micro-sensitive volumes of current electronic technologies. Dedicated numerical simulations demonstrate the importance of taking into account the entire stack of materials in order to get the most accurate estimations of TID in the sensitive oxide. Descriptions of the Back-End-Of-Line (BEOL) layers (especially when the technology uses Copper), the polysilicon gate, the BOX (for SOI devices), but also of the substrate and package are mandatory in these simulations, since dose enhancement and/or backscattered photons can be a significant source of TID variation in the gate oxide. Also the package lid composition and its thickness can be major TID contributors. The results show that the use of a pre-filter with lead and aluminum can optimize ionizing dose deposition.
16 April 2019 in IEEE Transactions on Nuclear Science
The TID sensitivity of mature and innovative technologies is investigated using both ionizing radiation experiments and Monte-Carlo simulations to discuss the potential of spectral photon radiation sources as an alternative for radiation effects studies. The impact of both technological and radiation test parameters on effective total ionizing dose deposition is also discussed. All the layers struck by the incident radiation flux before reaching the targeted sensitive oxide are the major contributors of final ionizing dose deposits, rather than the actual sensitive oxide itself.
19 February 2024 in IEEE Transactions on Nuclear Science
In this paper, a heavy ion induced Single Event Transient compact model is presented for Body Contacted PDSOI MOS transistor, which is interfaced with our Geant4 particle-matter interaction code. Cross comparisons with TCAD simulations are provided as well as some modeling adds-on to existing models, addressing the case of energy deposition in the source and drain and improving the body discharge description through the body contact. In previous works, the experimental calibration of existing compact models rarely relies on the transistor level collected charge distribution, measured during a heavy ions irradiation run. Still the collected charge is a key measurable quantity as its value strongly influences circuit level effects (like SEU in memories). Moreover, reproducing the collected charge distribution within an irradiation run through simulation is providing a proof that the stochastic nature of the experiment is correctly captured by the SET compact model. In this work, we expose an experimental statistical calibration procedure based on collected charges data obtained in GANIL.
20 January 2025 in IEEE Transactions on Nuclear Science
In this paper, a doped FDSOI behavior for the 65 nm PDSOI technology is demonstrated in order to understand the output voltage shift of a voltage reference undergoing dose deposition in real time. From an in-depth top-bottom analysis, including both experiments and TCAD/SPICE simulations, we highlighted this unexpected doped FDSOI behavior. This study shows how it worsens the total ionizing dose effects due to the coupling effect between the front and back interfaces, not usual in this technology. A new threshold voltage model considering the channel doping and total ionizing dose is developed showing how doping concentration is an important hardening parameter. This model is reused, in a multiscale approach, to reproduce the output voltage shift of a voltage reference based on the PDSOI transistor degradation.
1 September 2026 in IEEE Transactions on Nuclear Science