Yingxin Qiu

Yingxin Qiu

Auto-generated profile, based on publicly available information

Yingxin Qiu

George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
MWMengnan Wu
Mengnan Wu
YQYingxin Qiu
Yingxin Qiu
JUJun Ueda
Jun Ueda
LTLena H. Ting
Lena H. Ting
Robotic devices that interact with humans at the hands through haptic communication – instead of mechanical power transmission – represent an intuitive way to assist persons with physical disabilities and teach movement skills. Principles of human-human haptic communication during walking could inspire novel robot controllers capable of altering specific spatiotemporal gait parameters, not just walking speed. However, we know little about how hand interactions affect gait parameters, as existing hand-contact robots have several performance limitations that hinder rapid testing of different controllers and parameters. Here we present the design and validation of Slidey, a novel robotic testbed capable of emulating diverse hand interactions to alter human gait parameters. A lightweight, instrumented linear stage translating on a >5 m long track, Slidey allows overground walking at speeds ≤2.4 m/s; high-fidelity current and position control at >500 Hz and ∼6 Hz, respectively; and stable rendering of a range of admittances (mass ≤10 kg, damping ≤20 N/(m/s)). We show proof-of-concept that Slidey has adequate functionality to target changes in step length or step frequency. Slidey can act as a high-fidelity robotic emulator to rapidly investigate, evaluate, and personalize robot controllers to alter gait through haptic communication at the hand.

4 March 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
YQYingxin Qiu
Yingxin Qiu
MWMengnan Wu
Mengnan Wu
LTLena H. Ting
Lena H. Ting
JUJun Ueda
Jun Ueda
System identification of a dynamic environment using a robotic device utilizes physical perturbations in the form of displacement or force. To obtain an accurate system model, physical perturbations must be informative, which can be characterized by their spectral properties. The process of generating physical perturbations by using a robotic device often leads to spectral property degradation in the high-frequency region due to the dynamics of robot motion control and discrete-time signal processing. Spectral flatness is a metric applicable to quantifying the fidelity of the robotic system and quality of physical perturbations on an external object. This letter introduces a new metric named Band-limited Spectral Flatness Gain (BLSFG) to evaluate the physical perturbation quality relative to the input reference over a frequency band of interest. Motion control of a manipulandum that generates pseudorandom position perturbations for human sensorimotor system identification is considered as a representative example. The closed-loop system dynamics of the position control is characterized and optimized based on the BLSFG. Results suggest that a certain underdamped closed-loop property is advantageous to improve the spectral flatness of a degraded continuous-time pseudorandom reference. A high BLSFG is achieved when the resonance frequency of the closed-loop system is close to the update frequency of the pseudorandom sequence.

31 October 2022 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
YQYingxin Qiu
Yingxin Qiu
MWMengnan Wu
Mengnan Wu
LTLena H. Ting
Lena H. Ting
JUJun Ueda
Jun Ueda
System identification techniques have been applied to model human sensorimotor systems for research and diagnostic purposes. Accurate human modeling via system identification requires informative experimental data, which further require informative perturbations applied to the human. Previously, designing ideal perturbations for system identification has been extensively studied. On the other hand, the physical realization of perturbations often produces distorted perturbations, resulting in less accurate system identification and incorrect conclusions about the target dynamic system. However, such issues associated with an uncompensated physical realization process have not been fully resolved in the literature. A notable application is the design and use of the pseudorandom sequence (PRS). This article considers the physical realization of PRS perturbations. The impact of zero-order-hold (ZOH) on perturbation quality in terms of the previously proposed band-limited spectral flatness measure (SFM) is identified. To compensate for the spectral flatness degradation due to ZOH, a reference prefilter designed by the Parks–McClellan algorithm is incorporated into the motion control design. A relationship between the prefilter performance and band-limited SFM is established, based on which a prefilter design procedure that guarantees an SFM lower bound of the physically realized perturbations is proposed. Experimental results demonstrated that the proposed prefilter design method effectively improves the SFM of the physical perturbations.

29 August 2025 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
YQYingxin Qiu
Yingxin Qiu
MWMengnan Wu
Mengnan Wu
LTLena H. Ting
Lena H. Ting
JUJun Ueda
Jun Ueda
System identification of human sensorimotor systems requires multiple experimental trials to achieve reliable parameter estimates, yet practical constraints limit the total number of trials possible. While pseudorandom sequence (PRS) perturbations are widely used due to their white noise-like properties, and optimal multisines can theoretically provide better performance when prior system knowledge is available, their implementation on mechanical devices presents significant challenges. Device dynamics can degrade the designed spectral properties of both perturbation types, increasing the number of required trials to achieve desired estimation precision. This paper presents a foundational framework for device-dynamicsaware perturbation design that reduces the necessary number of experimental trials. The framework introduces two key components: a prefilter for PRS to minimize digital-to-analog conversion effects, and a modified cost function for multisine optimization that explicitly compensates for mechanical device dynamics. We propose a two-stage approach where the prefiltered PRS first provides initial estimates that inform subsequent optimal multisine design. Through human arm impedance experiments and devicerendered validation, we demonstrate that our framework achieves much smaller covariance resulting in fewer trials to achieve satisfactory identification performance compared to conventional methods. The optimal multisine stage, enhanced by device dynamics compensation, shows particular effectiveness in reducing parameter covariance. The covariance improvement translates to multiple practical benefits: a potential 62.5% reduction in required trial numbers when full-length signals are used, a 75% reduction in single-trial duration while maintaining estimation quality, or various combinations of these improvements depending on experimental constraints. These results establish a practical path toward more efficient human system identification protocols that minimize experimental burden while maintaining estimation accuracy.