Uffe Møller Døhn

Uffe Møller Døhn

Auto-generated profile, based on publicly available information

Uffe Møller Døhn

Department of Rheumatology and Spine Diseases Rigshospitalet Copenhagen Denmark

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2006 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
UDUffe Møller Døhn
Uffe Møller Døhn
BEBo J Ejbjerg
Bo J Ejbjerg
MCMichel Court-Payen
Michel Court-Payen
MHMaria Hasselquist
Maria Hasselquist
ENEva Narvestad
Eva Narvestad
MØMikkel Østergaard
Mikkel Østergaard
The objective of the study was, with multidetector computed tomography (CT) as the reference method, to determine whether bone erosions in rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints detected with magnetic resonance imaging (MRI) and ultrasonography (US), but not with radiography, represent true erosive changes. We included 17 RA patients with at least one, previously detected, radiographically invisible MCP joint MRI erosion, and four healthy control individuals. They all underwent CT, MRI, US and radiography of the 2nd to 5th MCP joints of one hand on the same day. Each imaging modality was evaluated for the presence of bone erosions in each MCP joint quadrant. In total, 336 quadrants were examined. The sensitivity, specificity and accuracy, respectively, for detecting bone erosions (with CT as the reference method) were 19%, 100% and 81% for radiography; 68%, 96% and 89% for MRI; and 42%, 91% and 80% for US. When the 16 quadrants with radiographic erosions were excluded from the analysis, similar values for MRI (65%, 96% and 90%) and US (30%, 92% and 80%) were obtained. CT and MRI detected at least one erosion in all patients but none in control individuals. US detected at least one erosion in 15 patients, however, erosion-like changes were seen on US in all control individuals. Nine patients had no erosions on radiography. In conclusion, with CT as the reference method, MRI and US exhibited high specificities (96% and 91%, respectively) in detecting bone erosions in RA MCP joints, even in the radiographically non-erosive joints (96% and 92%). The moderate sensitivities indicate that even more erosions than are seen on MRI and, particularly, US are present. Radiography exhibited high specificity (100%) but low sensitivity (19%). The present study strongly indicates that bone erosions, detected with MRI and US in RA patients, represent a loss of calcified tissue with cortical destruction, and therefore can be considered true bone erosions.

1 February 2011 in Annals of the Rheumatic Diseases
Verified
Journal Article
Open access
PDF file
UDUffe Møller Døhn
Uffe Møller Døhn
BEBo Ejbjerg
Bo Ejbjerg
ABAnnelies Boonen
Annelies Boonen
MHMerete Lund Hetland
Merete Lund Hetland
MHMichael Sejer Hansen
Michael Sejer Hansen
MØMikkel Østergaard
Mikkel Østergaard
Aim To monitor joint inflammation and destruction in rheumatoid arthritis (RA) patients receiving adalimumab/methotrexate combination therapy using MRI and ultrasonography. To assess the predictive value of MRI and ultrasonography for erosive progression on CT and compare MRI/ultrasonography/radiography for erosion detection/monitoring. Methods Fifty-two erosive biological-naive RA patients were followed with repeated MRI/ultrasonography/radiography (0/6/12 months) and clinical/biochemical assessments during adalimumab/methotrexate combination therapy. Results No overall erosion progression or repair was observed at 6 or 12 months (Wilcoxon; p>0.05), but erosion progressors and regressors were observed using the smallest detectable change cut-off. Scores of MRI synovitis, grey-scale synovitis (GSS) and power Doppler ultrasonography decreased after 6 and 12 months (p<0.05), as did DAS28, HAQ and tender and swollen joint counts (p<0.001). Patients with progression on CT had higher baseline MRI bone oedema scores. The RR for CT progression in bones with versus without baseline MRI bone oedema was 3.8 (95% CI 1.5 to 9.3) and time-integrated MRI bone oedema, power Doppler and GSS scores were higher in bones/joints with CT progression (Mann–Whitney; p<0.05). With CT as the reference method, sensitivities/specificities for erosion in metacarpophalangeal joints were 68%/92%, 44%/95% and 26%/98% for MRI, ultrasonography and radiography, respectively. Median intraobserver correlation coefficient was 0.95 (range 0.44–0.99). Conclusion During adalimumab/methotrexate combination therapy, no overall erosive progression or repair occurred, whereas repair of individual erosions was documented on MRI, and MRI and ultrasonography synovitis decreased. Inflammation on MRI and ultrasonography, especially MRI bone oedema, was predictive for erosive progression on CT, at bone/joint level and MRI bone oedema also at patient level.

28 February 2008 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
UDUffe Møller Døhn
Uffe Møller Døhn
BEBo J Ejbjerg
Bo J Ejbjerg
MHMaria Hasselquist
Maria Hasselquist
ENEva Narvestad
Eva Narvestad
JMJakob Møller
Jakob Møller
MØMikkel Østergaard
Mikkel Østergaard
Background: The objectives of the present study were, with multidetector computed tomography (CT) as the reference method, to determine the performance of magnetic resonance imaging (MRI) and radiography for the detection of bone erosions in rheumatoid arthritis wrist bones, and to test whether measuring volumes of erosions on CT and MRI is reproducible and correlated to semiquantitative assessments (scores) of erosions on CT, MRI and radiography. Methods: Seventeen patients with rheumatoid arthritis and four healthy control individuals underwent CT, MRI and radiography of one wrist, performed on the same day. CT was performed on a Philips Mx8000IDT unit (voxel size 0.4 mm × 0.4 mm × 1 mm) and MRI was performed on a Philips Panorama 0.6T unit (voxel size 0.4 mm × 0.4 mm × 0.4 mm). Images were evaluated separately for erosions in all wrist bones and were scored according to the principles of the Outcome Measures in Rheumatology Rheumatoid Arthritis MRI Scoring System (CT and MRI) and the Sharp/van der Heijde (radiographs) scoring methods. Measurements of erosion volumes of all erosions were performed twice with a 1-week interval. Results: With CT as the reference method, the overall sensitivity, specificity and accuracy (concordance) of MRI for detecting erosions were 61%, 93% and 77%, respectively, while the respective values were 24%, 99% and 63% for radiography. The intramodality agreements when measuring erosion volumes were high for both CT and MRI (Spearman correlation coefficients 0.92 and 0.90 (both P < 0.01), respectively). Correlations between volumes and scores of individual erosions were 0.96 for CT and 0.99 for MRI, while they were 0.83 (CT) and 0.80 (MRI) for persons' total erosion volume and total score (all P < 0.01). Conclusion: With CT as the reference method, MRI showed moderate sensitivity and good specificity and accuracy for detection of erosions in rheumatoid arthritis and healthy wrist bones, while radiography showed very low sensitivity. The tested volumetric method was highly reproducible and correlated to scores of erosions.

1 October 2007 in Annals of the Rheumatic Diseases
Verified
Journal Article
Closed access
PDF file
UDUffe Møller Døhn
Uffe Møller Døhn
BEBo J Ejbjerg
Bo J Ejbjerg
MHMaria Hasselquist
Maria Hasselquist
ENEva Narvestad
Eva Narvestad
MCMichel Court-Payen
Michel Court-Payen
MØMikkel Østergaard
Mikkel Østergaard
Objectives: To investigate intramodality and intermodality agreements of CT and MRI erosion volumes in metacarpophalangeal (MCP) joints in rheumatoid arthritis (RA), and to compare the volumes with erosion scores for CT, MRI and radiography. Methods: In total, 17 patients with RA and four healthy controls underwent unilateral CT, MRI and radiography of second to fifth MCP joints in one hand. Erosion volumes (using OSIRIS software) and scores were determined from CT, MRI and radiography (scores only). Results: CT, MRI and radiography detected 77, 62 and 12 erosions, respectively. On CT, the mean erosion volume was 26 mm3 (median 10; range 0 to 248) and 30 mm3 (18; 1 to 163) on MRI. Total erosion volumes (per patient/control) were 97 mm3 (29; 0 to 485) on CT and 90 mm3 (46; 0 to 389) on MRI. For volumes, Spearman correlation coefficients were 0.96 to 0.99 (CT vs CT), 0.95 to 0.98 (MRI vs MRI) and 0.64 to 0.89 (CT vs MRI), all p<0.01. MRI erosion volumes correlated with the Outcome Measures in Rheumatology Clinical Trials/Rheumatoid Arthritis Magnetic Resonance Imaging Score (OMERACT RAMRIS) erosion scores (0.91 to 0.99; p<0.01) and the Sharp/van der Heijde erosion score (0.49 to 0.63; p<0.01). Conclusion: Very high intramodality and high intermodality agreements of CT and MRI erosion volumes were found, encouraging further testing in longitudinal studies. A close correlation with CT and MRI erosion volumes supports the OMERACT RAMRIS erosion score as a valid measure of joint destruction in RA.

1 October 2009 in Annals of the Rheumatic Diseases
Verified
Journal Article
Closed access
PDF file
UDU Møller Døhn
U Møller Døhn
ABA Boonen
A Boonen
MHM L Hetland
M L Hetland
MHM S Hansen
M S Hansen
LKL S Knudsen
L S Knudsen
MØM Østergaard
M Østergaard
Objective: With computed tomography (CT) and radiography, to investigate if repair of bone erosions, defined as regression of erosion scores, occurs during adalimumab treatment of patients with rheumatoid arthritis (RA). Methods: Fifty-two patients with RA, naïve to biological agents, with at least two low-grade radiographic erosions in the wrist or metacarpophalangeal (MCP) joints in the same (index) hand, initiated adalimumab 40 mg subcutaneously every other week. Thirty-five patients completed the study (median age 61 years (interquartile range 46–68), disease duration 8 years (3–15)). CT of the index wrist and MCP joints 2–5 and radiographs of hands and forefeet were obtained at baseline, 6 and 12 months. Images were evaluated by investigators blinded to chronology and clinical data, and assessed according to Sharp/van der Heijde (radiographs) and OMERACT RA MRI scoring (CT) methods. Results: Disease activity score, C-reactive protein, tender and swollen joints count and Health Assessment Questionnaire score had all decreased at 6 and 12 months (wilcoxon signed-ranks test p<0.001). No significant change in any imaging parameters of joint destruction was observed at 6 and 12 months. High intrareader agreements were reached (mean intraobserver intraclass coefficients: 0.96 (CT) and 0.97 (radiography)). The number of patients with change scores exceeding the smallest detectable change (SDC) was comparable on CT and radiography, as were the proportions of patients progressing/regressing. Decreased erosion scores at 12 months were registered in 1.6% and 1.8% of sites assessed on CT and radiography, respectively. Conclusion: Repair of erosions in adalimumab-treated patients with RA is rare, but erosive regression, exceeding the SDC, on CT and radiography occurred. The very limited overall erosive progression supports the view that joint destruction is minimal during adalimumab treatment of patients with RA.

20 July 2017 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
LTLene Terslev
Lene Terslev
ADA. P. Diamantopoulos
A. P. Diamantopoulos
UDU. Møller Døhn
U. Møller Døhn
WSW. A. Schmidt
W. A. Schmidt
STS. Torp-Pedersen
S. Torp-Pedersen
Ultrasound is used increasingly for diagnosing large vessel vasculitis (LVV). The application of Doppler in LVV is very different from in arthritic conditions. This paper aims to explain the most important Doppler parameters, including spectral Doppler, and how the settings differ from those used in arthritic conditions and provide recommendations for optimal adjustments. This is addressed through relevant Doppler physics, focusing, for example, on the Doppler shift equation and how angle correction ensures correctly displayed blood velocity. Recommendations for optimal settings are given, focusing especially on pulse repetition frequency (PRF), gain and Doppler frequency and how they impact on detection of flow. Doppler artefacts are inherent and may be affected by the adjustment of settings. The most important artefacts to be aware of, and to be able to eliminate or minimize, are random noise and blooming, aliasing and motion artefacts. Random noise and blooming artefacts can be eliminated by lowering the Doppler gain. Aliasing and motion artefacts occur when the PRF is set too low, and correct adjustment of the PRF is crucial. Some artefacts, like mirror and reverberation artefacts, cannot be eliminated and should therefore be recognised when they occur. The commonly encountered artefacts, their importance for image interpretation and how to adjust Doppler setting in order to eliminate or minimize them are explained thoroughly with imaging examples in this review.