Björn Andersen

Björn Andersen

Auto-generated profile, based on publicly available information

Björn Andersen

Institute of Medical Informatics, University of Lübeck, 23562 Lübeck, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2018 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
MKMartin Kasparick
Martin Kasparick
MSMalte Schmitz
Malte Schmitz
BABjörn Andersen
Björn Andersen
MRMax Rockstroh
Max Rockstroh
SFStefan Franke
Stefan Franke
DTDirk Timmermann
Dirk Timmermann
Modern surgical departments are characterized by a high degree of automation supporting complex procedures. It recently became apparent that integrated operating rooms can improve the quality of care, simplify clinical workflows, and mitigate equipment-related incidents and human errors. Particularly using computer assistance based on data from integrated surgical devices is a promising opportunity. However, the lack of manufacturer-independent interoperability often prevents the deployment of collaborative assistive systems. The German flagship project OR.NET has therefore developed, implemented, validated, and standardized concepts for open medical device interoperability. This paper describes the universal OR.NET interoperability concept enabling a safe and dynamic manufacturer-independent interconnection of point-of-care (PoC) medical devices in the operating room and the whole clinic. It is based on a protocol specifically addressing the requirements of device-to-device communication, yet also provides solutions for connecting the clinical information technology (IT) infrastructure. We present the concept of a service-oriented medical device architecture (SOMDA) as well as an introduction to the technical specification implementing the SOMDA paradigm, currently being standardized within the IEEE 11073 service-oriented device connectivity (SDC) series. In addition, the Session concept is introduced as a key enabler for safe device interconnection in highly dynamic ensembles of networked medical devices; and finally, some security aspects of a SOMDA are discussed.

22 December 2017 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
BABjörn Andersen
Björn Andersen
MKMartin Kasparick
Martin Kasparick
HUHannes Ulrich
Hannes Ulrich
SFStefan Franke
Stefan Franke
JSJan Schlamelcher
Jan Schlamelcher
JIJosef Ingenerf
Josef Ingenerf
The new medical device communication protocol known as IEEE 11073 SDC is well-suited for the integration of (surgical) point-of-care devices, so are the established Health Level Seven (HL7) V2 and Digital Imaging and Communications in Medicine (DICOM) standards for the communication of systems in the clinical IT infrastructure (CITI). An integrated operating room (OR) and other integrated clinical environments, however, need interoperability between both domains to fully unfold their potential for improving the quality of care as well as clinical workflows. This work thus presents concepts for the propagation of clinical and administrative data to medical devices, physiologic measurements and device parameters to clinical IT systems, as well as image and multimedia content in both directions. Prototypical implementations of the derived components have proven to integrate well with systems of networked medical devices and with the CITI, effectively connecting these heterogeneous domains. Our qualitative evaluation indicates that the interoperability concepts are suitable to be integrated into clinical workflows and are expected to benefit patients and clinicians alike. The upcoming HL7 Fast Healthcare Interoperability Resources (FHIR) communication standard will likely change the domain of clinical IT significantly. A straightforward mapping to its resource model thus ensures the tenability of these concepts despite a foreseeable change in demand and requirements.

4 March 2019 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
MKMartin Kasparick
Martin Kasparick
BABjörn Andersen
Björn Andersen
SFStefan Franke
Stefan Franke
MRMax Rockstroh
Max Rockstroh
FGFrank Golatowski
Frank Golatowski
TNThomas Neumuth
Thomas Neumuth
Acute patient treatment can heavily profit from AI-based assistive and decision support systems, in terms of improved patient outcome as well as increased efficiency. Yet, only very few applications have been reported because of the limited accessibility of device data due to the lack of adoption of open standards, and the complexity of regulatory/approval requirements for AI-based systems. The fragmentation of data, still being stored in isolated silos, results in limited accessibility for AI in healthcare and machine learning is complicated by the loss of semantics in data conversions. We outline a reference model that addresses the requirements of innovative AI-based research systems as well as the clinical reality. The integration of networked medical devices and Clinical Repositories based on open standards, such as IEEE 11073 SDC and HL7 FHIR, will foster novel assistance and decision support. The reference model will make point-of-care device data available for AI-based approaches. Semantic interoperability between Clinical and Research Repositories will allow correlating patient data, device data, and the patient outcome. Thus, complete workflows in high acuity environments can be analysed. Open semantic interoperability will enable the improvement of patient outcome and the increase of efficiency on a large scale and across clinical applications.

3 February 2018 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
MRMax Rockstroh
Max Rockstroh
SFStefan Franke
Stefan Franke
RDRaluca Dees
Raluca Dees
AMAngela Merzweiler
Angela Merzweiler
GSGerd Schneider
Gerd Schneider
TNThomas Neumuth
Thomas Neumuth
The effective development and dissemination of the open integration for the next generation of operating rooms require a comprehensive testing environment. In this paper, we present the various challenges to be addressed in demonstration applications, and we discuss the implementation approach, the foci of the demonstration sites and the evaluation efforts. Overall, the demonstrator setups have proven the feasibility of the service-oriented medical device architecture (SOMDA) and real-time approaches with a large variety of example applications. The applications demonstrate the potentials of open device interoperability. The demonstrator implementations were technically evaluated as well as discussed with many clinicians from various disciplines. However, the evaluation is still an ongoing research at the demonstration sites. Technical evaluation focused on the properties of a network of medical devices, latencies in data transmission and stability. A careful evaluation of the SOMDA design decisions and implementations are essential to a safe and reliable interoperability of integrated medical devices and information technology (IT) system in the especially critical working environment. The clinical evaluation addressed the demands of future users and stakeholders, especially surgeons, anesthesiologists, scrub nurses and hospital operators. The opinions were carefully collected to gain further insights into the potential benefits of the technology and pitfalls in future work.

1 January 2015
Verified
Journal Article
Closed access
AKAnn-Kristin Kock
Ann-Kristin Kock
RKRafiye Kaya
Rafiye Kaya
CMChristian Müller
Christian Müller
BABjörn Andersen
Björn Andersen
TLThorsten Langer
Thorsten Langer
JIJosef Ingenerf
Josef Ingenerf

1 January 2019
Verified
Book Chapter
Open access
PDF file
ABAndersen Björn
Andersen Björn
BSBaumhof Simon
Baumhof Simon
JIJosef Ingenerf
Josef Ingenerf
There are IEEE 11073 standards for foundational, structural, and semantic point-of-care medical device interoperability, but the first devices with this interface have yet to enter the market. One of the missing pieces for implementation and approval are Device Specialisations that specify how to use information and service models to represent a specific type of device on the network. Required and optional metrics need to be standardised as well as nomenclature terms, units of measure, and extension points. Finally, device-to-device interaction at runtime has to be defined for automatic verification during testing and approval. Applications include C-arm fluoroscopes used in different clinical settings.