Sandipan Dhar

Sandipan Dhar

Auto-generated profile, based on publicly available information

Sandipan Dhar

Department of Applied Physics, University of Calcutta, Kolkata, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Measurement
Verified
Journal Article
Closed access
SDS. Dhar
S. Dhar
SMS.K. Mukhopadhyay
S.K. Mukhopadhyay
SPS. Pal
S. Pal
MMM. Mitra
M. Mitra

22 July 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DSDeboleena Sadhukhan
Deboleena Sadhukhan
SDSandipan Dhar
Sandipan Dhar
SPSaurabh Pal
Saurabh Pal
MMMadhuchhanda Mitra
Madhuchhanda Mitra
Integration of automated cardiac analysis techniques with the personal healthcare devices can aid in the timely diagnosis of myocardial infarction (MI) to reduce the risk of mortality. The use of electrocardiogram (ECG) along with advanced signal processing tools limits the application of the available techniques for such portable devices having limited processing ability. Here we propose a novel MI screening technique based on photoplethysmographic (PPG) data, which is the most widely monitored signal in everyday health monitoring. Two simple statistical features ideally reflecting the MI induced variability in the PPG data are identified. To combat with the noise sensitivity of the PPG acquisition process the same statistical parameters are employed for eliminating the noise corrupted data segments. Classification of MI data is then performed using simple threshold based binary classification approach. The technique is evaluated with PPG records collected from 62 hospitalized MI patients and 65 healthy subjects. The robustness of the algorithm is cross validated with both MI and non-MI records collected from the MIMIC II database. The algorithm achieves an average detection accuracy of 96.25sensitivity and specificity of 96.36% and 96.15%, respectively. The promising results establish the utility of PPG as an alternate MI diagnosing tool. Apart from using the less obtrusive PPG signal, the proposed technique relies on simple feature extraction and classification tools; thus, making it a promising alternative to the ECG based techniques for implementation on the personal healthcare devices.

1 January 2014
Verified
Conference Paper
Closed access
SDS. Dhar
S. Dhar
SMS. K. Mukhopadhyay
S. K. Mukhopadhyay
SMS. Mitra
S. Mitra
MBM. M. Baig
M. M. Baig
MMM. Mitra
M. Mitra
An effective and reliable noise reduction and Electrocardiogram (ECG) feature extraction algorithm is proposed in this paper. Contaminated ECG samples are de-noised using a Butterworth lowpass and IIR notch filter. First derivative using Lagrange Five Point Interpolation formula and Hilbert Transform of those ECG samples are computed. Sample having maximum amplitude is found out from the transformed data and those samples having amplitude within a lead wise specific threshold of that maximum are selected. The point where those selected samples undergo slope alteration in the original time domain ECG signal is marked as R peak. After successful identification of R peak points, base line modulation correction is implemented using an empirically determined formula. Q and S points are identified by finding minimum amplitude on the either side of the most recently detected R peak. QRS onset and offset points are also detected. After detecting all these characteristic points, Heart Rate, R, Q and S peak heights and QRS duration are measured. Errors in these extracted ECG features are also calculated. The algorithm offers a good level of Sensitivity (99.84%), Positive Predictivity (99.84%) and Detection Accuracy (99.84%) of R peak. Different types of ECG data of all the 12 leads taken from PTB diagnostic ECG database (PTB-DB) is used for testing the performance of the proposed module.

27 January 2022 in Sādhanā
Verified
Journal Article
Closed access
PDF file
SDSandipan Dhar
Sandipan Dhar
ACAbhishek Chakraborty
Abhishek Chakraborty
DSDeboleena Sadhukhan
Deboleena Sadhukhan
SPSaurabh Pal
Saurabh Pal
MMMadhuchhanda Mitra
Madhuchhanda Mitra

28 January 2020 in Journal of Crystal Growth
Verified
Journal Article
Closed access
SDSubhasis Das
Subhasis Das
ASAkant Sagar Sharma
Akant Sagar Sharma
SGSanowar Alam Gazi
Sanowar Alam Gazi
SDS. Dhar
S. Dhar

1 January 2014
Verified
Conference Paper
Closed access
SDS. Dhar
S. Dhar
SMS. K. Mukhopadhyay
S. K. Mukhopadhyay
SMS. Mitra
S. Mitra
MBM. M. Baig
M. M. Baig
MMM. Mitra
M. Mitra
This paper proposes an efficient technique to eliminate high frequency and power line interference noise from digitized Electrocardiogram (ECG) signal and compression of that enhanced signal in a lossless manner. ECG data of different diseases taken from PTB diagnostic ECG database (PTB-DB) is used to test the performance of the module. At first, contaminated ECG signal is passed through a Butterworth lowpass filter to remove high frequency noises whose order is chosen on experimental basis. To remove power line interference noise, an IIR notch filter is designed properly. Enhanced signal is compressed using a strict lossless technique. The proposed module can reduce noise as well as ECG data file size efficiently.