16 August 2022 in Proceedings of the National Academy of Sciences
As nitric oxide (NO) plays significant roles in a variety of physiological processes, the capability for real-time and accurate detection of NO in live organisms is in great demand. Traditional assessments of NO rely on indirect colorimetric techniques or electrochemical sensors that often comprise rigid constituent materials and can hardly satisfy sensitivity and spatial resolution simultaneously. Here, we report a flexible and highly sensitive biosensor based on organic electrochemical transistors (OECTs) capable of continuous and wireless detection of NO in biological systems. By modifying the geometry of the active channel and the gate electrodes of OECTs, devices achieve optimum signal amplification of NO. The sensor exhibits a low response limit, a wide linear range, high sensitivity, and excellent selectivity, with a miniaturized active sensing region compared with a conventional electrochemical sensor. The device demonstrates continuous detection of the nanomolar range of NO in cultured cells for hours without significant signal drift. Real-time and wireless measurement of NO is accomplished for 8 d in the articular cavity of New Zealand White rabbits with anterior cruciate ligament (ACL) rupture injuries. The observed high level of NO is associated with the onset of osteoarthritis (OA) at the later stage. The proposed device platform could provide critical information for the early diagnosis of chronic diseases and timely medical intervention to optimize therapeutic efficacy.
21 April 2023 in IEEE Journal of Solid-State Circuits
This article proposed the first fully integrated synchronous electric-charge extraction (SECE) interface, featuring: 1) no external passive components and the smallest normalized on-chip capacitance; 2) an increased energy-extraction efficiency; and 3) a maximized extracted power regardless of the input and output conditions. With the multi-step soft-charging (MSC) technique relaxing energy-extraction conduction loss, we can effectively minimize the on-chip capacitance while improving the energy-extraction efficiency. To further depress the control loss, the positive current selector (PCS) is proposed to realize digital rectification during charge extraction. With the SECE strategy facilitating output independence, we further investigate an automatic phase and amplitude tuning method to enable maximum-power-point tracking (MPPT) over an extended input excitation bandwidth. Fabricated in 0.18- $\mu$ m CMOS, the proposed rectifier achieves a maximum output power improving rate (MOPIR) of 8.14 $\times$ with $V_D$ $=$ 0.12 V and a 405% bandwidth improvement over the piezoelectric energy harvester (PEH) natural bandwidth.
14 November 2022 in IEEE Open Journal of the Solid-State Circuits Society
Electrochemical detection is widely used in biosensing fields such as medical diagnosis and health monitoring due to its real-time response and high accuracy. Both passive and active electrodes and the corresponding readout circuits have been continuously improved over the past decades. This paper summarizes the redox reaction method, state-of-the-art electrode materials and readout circuits based on passive three-electrode. The redox current-based readout circuits are widely used and developed toward multi-channel high precision and low power consumption. In terms of active electrodes, this paper reviews the development of field-effect transistors (FETs)-based electrochemical detection and readout circuits. In the past decade, the development of organic electrochemical transistors (OECTs) have also enabled more precise electrochemical detection.
14 February 2025 in IEEE Journal of Solid-State Circuits
This article proposes a compact low-power sub-2.4-GHz transceiver (TRX) with a all-digital phase-locked loop (ADPLL)-based transmitter (TX) and a single-path phase-tracking receiver (RX) in a 40-nm CMOS process. To meet the requirements for low output power in the medical band as well as to reduce power consumption, a single-ended class-E power amplifier (PA) with a duty-cycle-controlled strategy is proposed. A fully integrated on-chip matching network is designed to satisfy the impedance matching criteria for the class-E PA. The issues of the 2nd-order and the 3rd-order harmonic suppression are resolved by a series resonator and a capacitor in parallel with a segmented transformer, respectively. In the RX, the on-chip transformer also serves as an input impedance matching network for the low-noise transconductance amplifier (LNTA), reducing the required transconductance through passive reverse voltage gain. The transformer is capable of suppressing noise. The structure of the matching network only requires one transformer and one inductor, thereby reducing the count of passive components. Additionally, it features an embedded transmitter/receiver (T/R) switch function without insertion loss. The proposed 8-port transformer makes the layout more flexible and compact. The TX consumes 2.27 mW at −10-dBm output power and 5.45 mW at 0 dBm. A 2nd-order harmonic distortion of −52.36 dBm and a 3rd-order harmonic distortion of −50.67 dBm are measured, respectively. The RX consumes 2.25 mW and achieves a sensitivity of −93 dBm. The proposed TRX with reused matching networks results in an active silicon area of only 0.48 mm2.
16 November 2023 in IEEE Solid-State Circuits Magazine
Neural interfaces play an important role in vital sign monitoring [1] , clinical practice [2] , and neuroscience frontier research [3] using animal subjects, such as rodents and nonhuman primates [4] , [5] . Recently, neuroscientists have shown increasing interest in behavioral analysis of social situations with a single or multiple freely moving animals, which has been listed as a key investment by the NIH in 2023 [6] . Among those popular laboratory animals, marmosets are increasingly favored by researchers because of their small size, short sexual maturity, complex social patterns, and similarity to human beings [7] , [8] . A number of marmoset social behaviors, such as gaze following [9] , antiphonal calling [10] , and scent marking [11] , have been studied with neural signal acquisition and/or stimulation to affect the behavior of the freely moving marmoset at the same time.