26 August 2021 in IEEE Transactions on Power Systems
This paper deals with the transient stability of a grid-forming converter while embedding a current reference saturation strategy. The novelty of this work consists in investigating the impact of the current reference angle on the transient stability. In case of a balanced voltage sag, analytical formulas to estimate the critical clearing angle (CCA) and critical clearing time (CCT) while considering different values of the current reference angle are derived. It is demonstrated that the choice of this angle is constrained by the ability of the power converter to switch back to the voltage control mode. Based on that, its optimal value that enhances the transient stability and allows a switching from the saturated current control mode to the voltage control mode is calculated. Thereafter, the effectiveness of this optimal choice to guarantee the stability in case of a phase shift caused by a line re-closing event is verified. Time-domain simulations and experimental tests validate the correctness of the presented theoretical approaches.
27 October 2020 in IEEE Access
This paper proposes a grid-forming control strategy with a generic implementation approach to meet the transmission system requirements asking for the massive integration of power electronic devices into the power systems. In this context, several grid-forming controls have been proposed in the literature either with or without a Phase-Locked Loop (PLL). The PLL-based techniques allow decoupling the different control functionalities (i.e. inertia emulation, frequency support, active power setpoint tracking in steady-state) while the PLL-free schemes, which aim to avoid the PLL drawbacks, create a compulsory coupling between the control functionalities. The proposed grid-forming control in this paper is able to decouple the control functionalities without any dedicated PLL, which makes it more advantageous compared to what have been already proposed in the literature. Since the power converters are exposed to the small and large grid events, the presented control has been tested in both situations. For the small grid events, a simplified small-signal model is developed to assess the active power and frequency dynamics. In case of large grid events, a current limitation algorithm is included to the control in order to protect the power converter. To deal with the transient stability issues linked to the current limitation and enhance the converter performance during the post-fault, a method based on adaptive inertia constant is proposed. To validate the overall approach, time-domain simulations (in Matlab-Simulink) and experimentations are performed.