Shengchang Tang

Shengchang Tang

Auto-generated profile, based on publicly available information

Shengchang Tang

School of Mechanical Engineering, Guangxi University, Nanning, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2024 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
STShengchang Tang
Shengchang Tang
XWXiangfu Wei
Xiangfu Wei
GHGuangyong Huang
Guangyong Huang
PDPeng Dai
Peng Dai
YCYongchao Cai
Yongchao Cai
HYHui You
Hui You
As the core technology in the field of microdroplet related applications, researchers have been striving to develop new driving methods and improve the stability of inkjet printing technology to meet the diverse needs of various materials and applications. In this study, a novel, simple, and cost-effective droplet printing method based on inertial force driving is proposed, and its printing characteristics and stability are investigated through experimental and numerical simulation studies. A numerical model was developed to explore the effects of operating parameters and fluid properties on the printing process. The results showed that for a given fluid, it is easier to form satellite droplets when driven from a smaller nozzle with higher voltage and pulse width. The hydrophilic nature of the nozzle can suppress the formation of satellite droplets, but it is prone to retain liquid, thereby affecting the next printing effect. Under certain operating conditions, fluids with lower density, higher viscosity, and higher surface tension are difficult to be driven but can suppress the formation of satellite droplets and promote printing stability. Finally, a parameter space composed of dimensionless numbers Op representing operating parameters and Z representing fluid properties (reciprocal of the Oh number) was established to investigate the comprehensive influence on the printing. The correctness of this parameter space in guiding the selection of parameters for stable droplet printing was validated through experiments.

21 November 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GHGuangyong Huang
Guangyong Huang
CSCuimin Sun
Cuimin Sun
XWXiangfu Wei
Xiangfu Wei
STShengchang Tang
Shengchang Tang
SWShixiong Wu
Shixiong Wu
HYHui You
Hui You
Intracellular delivery is among the biotechnological methods used for studying cell therapy, drug delivery, and biomanufacturing. Currently, ultrasound-mediated intracellular delivery with microfluidics has the advantage of being controllable and efficient. However, the conventional method of sonoporation through the generation of microbubbles in cavities faces challenges in maintaining optimal microbubble size and shape. In this paper, we present a device based on linear array microbubbles to induce acoustic streaming, which can regulate cell membrane permeability in a stable and controllable method. To solve these challenges,high-resolution photosensitive resin 3D printing is utilised to fabricate vertical array T-junction structures with significant aspect ratios for the generation of microbubbles. When microbubble volume changes due to environmental influences, the size of the microbubble cap remains constant due to the constraints of microchannel width, thus reducing the adverse effects of microbubble size variations and ensuring stable oscillation. Then cells are captured and trapped on the surface of microbubbles under the combined effects of oscillating microbubble-induced secondary acoustic radiation force and acoustic streaming, ultimately leading to alterations in the permeability of the cell membrane under shear stress. The experiments show that the delivery efficiency of 293T cells is 93.2 ± 2.3% while maintaining high cell viability at a driving voltage of 30 V. Furthermore, we have successfully delivered a plasmid encoding green fluorescent protein (8.2kbp) to the cells, and the experimental results show a transfection efficiency of 30.7 ± 2.8%. This novel acoustofluidic method achieves rapid, reusable intracellular delivery, and may have utility in microfluidic chip applications.

1 July 2025 in Physics of Fluids
Verified
Journal Article
Open access
JCJiaPeng Chen
JiaPeng Chen
CSCuiMin Sun
CuiMin Sun
GHGuangyong Huang
Guangyong Huang
STShengchang Tang
Shengchang Tang
HYHui You
Hui You
This study developed a technology for precise acoustic flow field manipulation using a variety of microbubble shapes (including circular, elliptical, triangular, and square) through an acoustofluidic chip system. By utilizing advanced fabrication techniques, the microcavity structure was optimally designed to achieve stable microbubble trapping. Employing 2 μm diameter polystyrene particle tracking technology, experimental results demonstrate that elliptical microbubbles can induce stable quadruple-vortex patterns. Unlike the dual-vortex limitation of spherical structures, elliptical structures stably generate quadruple-vortices across a broad frequency range (20–120 kHz), with a maximum velocity gradient of 35/s. The velocity gradient variation in this quadruple-vortex field is significantly smaller than that in dual-vortex patterns of other microbubbles, unlike other shapes that typically produced a dual-vortex pattern. Changes in excitation voltage affected the fluid velocity gradient around the microbubbles, with increased voltage resulting in a higher velocity gradient. Additionally, the choice of excitation frequency significantly impacted the flow field patterns of non-circular microbubbles. The key breakthrough lies in demonstrating that elliptical microbubbles can stably generate quadruple-vortex streaming, with significantly superior maximum velocity gradient and shear uniformity compared to conventional spherical microbubbles, offering additional flexibility for microbubble manipulation. These findings confirm the direct influence of microbubble shape on acoustic flow patterns. Moreover, our results reveal the potential of non-circular microbubbles in acoustic manipulation and introduce a new perspective to acoustic fluid engineering, emphasizing the importance of optimizing microbubble shape and frequency selection for future applications, particularly in drug delivery, cell manipulation, and biochemical analysis. Future research will focus on enhancing the practical efficiency of specific microbubble shapes, optimizing designs, and assessing their long-term environmental impact to promote sustainable development of the technology.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
STShengchang Tang
Shengchang Tang
FWFulei Wang
Fulei Wang
ZQZhipeng Qin
Zhipeng Qin
MYMengchuang Yin
Mengchuang Yin
CLCaijie Li
Caijie Li
HYHui You
Hui You
In this paper, the effects of the nozzle’s wettability on droplet dynamics at low Weber numbers were investigated experimentally. Deionized water droplets dripping from nozzles of different wettability were photographed using a high-speed camera. The studied droplet parameters mainly include the limit length of the filament, the thickness of the neck, the position of the neck, the size of the droplet and the satellite droplet, and the movement trend of the satellite droplet. We found that the wettability of the needle nozzle mainly influences the dynamic dripping process of droplets by changing the diameter of the contact circle of the three phases of gas, liquid, and solid. The transition of the satellite droplet behavior with the flow velocity and the diameter of the contact circle was further explored, and it was found that there are multiple critical transition states in the experimental parameter space. The change in the movement trend of satellite droplets is the result of the competition between surface tension and gravity. It is also affected by the flow rate, droplet oscillation, and interaction time.