Yang Lu

Yang Lu

Auto-generated profile, based on publicly available information

Yang Lu

Boston University, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
CSC. Stockbridge
C. Stockbridge
YLY. Lu
Y. Lu
JMJ. Moore
J. Moore
SHS. Hoffman
S. Hoffman
RPR. Paxman
R. Paxman
TBThomas Bifano
Thomas Bifano
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

7 September 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
MBMiguel O. Bernabeu
Miguel O. Bernabeu
YLYang Lu
Yang Lu
OAOmar Abu-Qamar
Omar Abu-Qamar
LALloyd P. Aiello
Lloyd P. Aiello
JSJennifer K. Sun
Jennifer K. Sun
Diabetic retinopathy (DR) is a leading cause of vision loss worldwide. Microaneurysms (MAs), which are abnormal outpouchings of the retinal vessels, are early and hallmark lesions of DR. The presence and severity of MAs are utilized to determine overall DR severity. In addition, MAs can directly contribute to retinal neural pathology by leaking fluid into the surrounding retina, causing abnormal central retinal thickening and thereby frequently leading to vision loss. Vascular perfusion parameters such as shear rate (SR) or wall shear stress (WSS) have been linked to blood clotting and endothelial cell dysfunction, respectively in non-retinal vasculature. However, despite the importance of MAs as a key aspect of diabetic retinal pathology, much remains unknown as to how structural characteristics of individual MAs are associated with these perfusion attributes. MA structural information obtained on high resolution adaptive optics scanning laser ophthalmoscopy (AOSLO) was utilized to estimate perfusion parameters through Computational Fluid Dynamics (CFD) analysis of the AOSLO images. The HemeLB solver was used to simulate steady-state and time-dependent flow using both commodity hospital-based and high-performance-computing resources, depending on the degree of detail required in the simulations. Our results indicate that WSS is lowest in MA regions furthest away from the feeding vessels. Furthermore, areas of low SR are associated with clot location in saccular MAs. These findings suggest that morphology and CFD estimation of perfusion parameters may be useful tools for determining the likelihood of clot presence in individual diabetic MAs.

19 May 2020 in eLife
Verified
Journal Article
Open access
MHMartin Hailstone
Martin Hailstone
DWDominic Waithe
Dominic Waithe
TSTamsin J Samuels
Tamsin J Samuels
LYLu Yang
Lu Yang
ICIta Costello
Ita Costello
IDIlan Davis
Ilan Davis
A major challenge in cell and developmental biology is the automated identification and quantitation of cells in complex multilayered tissues. We developed CytoCensus: an easily deployed implementation of supervised machine learning that extends convenient 2D ‘point-and-click’ user training to 3D detection of cells in challenging datasets with ill-defined cell boundaries. In tests on such datasets, CytoCensus outperforms other freely available image analysis software in accuracy and speed of cell detection. We used CytoCensus to count stem cells and their progeny, and to quantify individual cell divisions from time-lapse movies of explanted Drosophila larval brains, comparing wild-type and mutant phenotypes. We further illustrate the general utility and future potential of CytoCensus by analysing the 3D organisation of multiple cell classes in Zebrafish retinal organoids and cell distributions in mouse embryos. CytoCensus opens the possibility of straightforward and robust automated analysis of developmental phenotypes in complex tissues.

26 July 2010 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
CVCurtis Vogel
Curtis Vogel
GTGlenn Tyler
Glenn Tyler
YLYang Lu
Yang Lu
TBThomas Bifano
Thomas Bifano
RCRodolphe Conan
Rodolphe Conan
CBCelia Blain
Celia Blain
We present a variant of the model introduced by Vogel and Yang [J. Opt. Soc. Am. A 23, 1074 (2006)] for point-actuated deformable mirrors (DMs) with continuous facesheets, and we describe a robust efficient regularized- output least-squares computational scheme to estimate the parameters in the model, given noisy discrete observations of the DM response to known actuation. We demonstrate the effectiveness of this approach with experimental data obtained from a pair of DMs—a piezo-actuated prototype DM built by CILAS for the Thirty Meter Telescope Project and an electrostatically actuated commercial micro-electro-mechanical systems (MEMS) DM produced by Boston Micromachines Corporation.

8 November 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
YLYang Lu
Yang Lu
TBThomas Bifano
Thomas Bifano
Selim ÜnlüSelim Ünlü
Selim Ünlü
BGBennett Goldberg
Bennett Goldberg
The imaging quality of an aplanatic SIL microscope is shown to be significantly degraded by aberrations, especially when the samples have thicknesses that are more than a few micrometers thicker or thinner than the design thickness. Aberration due to the sample thickness error is modeled and compared with measurements obtained in a high numerical aperture (NA ~3.5) microscope. A technique to recover near-ideal imaging quality by compensating aberrations using a MEMS deformable mirror is described and demonstrated.

10 September 2010 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ADAlioune Diouf
Alioune Diouf
ALAndrew P. Legendre
Andrew P. Legendre
JSJason B. Stewart
Jason B. Stewart
TBThomas Bifano
Thomas Bifano
YLYang Lu
Yang Lu
We characterize the errors associated with open-loop control of a microelectromechanical system deformable mirror (DM) using an approach that combines sparse calibration of the electrostatic actuator state space with an elastic plate model of the mirror facesheet. We quantify sources of measurement error and modeling error and demonstrate that the DM can be shaped in a single step to a tolerance of ∼8nm of that achievable with iterative feedback-based closed-loop control. Zernike polynomials with up to 2.5μm amplitude were made with this approach and yielded a shape error of <25nm rms in most cases. Residual errors were shown to be due primarily to spatial resolution limits inherent in the DM (e.g., uncontrollable errors).